Lindsay Cunningham
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lindsay Cunningham has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Mike Walton
Upper Limb Research Department, Wrightington Hospital, Wrightington, UK
3 shared publications- David William Shields
Department of Trauma and Orthopaedics, Queen Elizabeth University Hospital, Glasgow, G51 4TF, UK
2 shared publications - Ian A. Trail
Wrightington Upper Limb Unit
2 shared publications - Mustafa Saad Rashid
East Suffolk and North Essex NHS Foundation Trust Colchester Essex UK
2 shared publications - Puneet Monga
Camden, NJ, USA .
2 shared publications - Amir Tavakoli
Camden, NJ, USA .
1 shared publication
Latest Publications
- Open Access
- 15 September 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (10) , A2-A10
Table of Contents
- 15 September 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (10) , A2-A10
Open AccessTable of Contents
- 1 August 2023
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (8) , 912-919
A prospective radiostereometric analysis of the stability of a metal-backed glenoid component/autograft composite in reverse shoulder arthroplasty
Aims: Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).Methods: A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.Results: RSA analysis showed a small increase in all translation and rotational values up to six months postoperatively, consistent with settling of the implant. The mean values plateaued by 12 months, with no evidence of further migration. In four patients, there was significant variation outside the mean, which corresponded to postoperative complications. There was a significant improvement in the clinical and patient-reported outcomes from the preoperative values to those at two years postoperatively (p < 0.001).Conclusion: These findings show, using RSA, that a glenoid baseplate composite of a trabecular titanium peg with autograft stabilizes within the glenoid about 12 months after surgery, and reinforce findings from a previous study of this implant/graft with CT scans at two years postoperatively, indicating that this type of structural composite results in sound early fixation.Cite this article: Bone Joint J 2023;105-B(8):912–919.
- 1 August 2023
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (8) , 912-919
A prospective radiostereometric analysis of the stability of a metal-backed glenoid component/autograft composite in reverse shoulder arthroplasty
Aims: Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).Methods: A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.Results: RSA analysis showed a small increase in all translation and rotational values up to six months postoperatively, consistent with settling of the implant. The mean values plateaued by 12 months, with no evidence of further migration. In four patients, there was significant variation outside the mean, which corresponded to postoperative complications. There was a significant improvement in the clinical and patient-reported outcomes from the preoperative values to those at two years postoperatively (p < 0.001).Conclusion: These findings show, using RSA, that a glenoid baseplate composite of a trabecular titanium peg with autograft stabilizes within the glenoid about 12 months after surgery, and reinforce findings from a previous study of this implant/graft with CT scans at two years postoperatively, indicating that this type of structural composite results in sound early fixation.Cite this article: Bone Joint J 2023;105-B(8):912–919.
- 30 May 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (10) , 2017-2026
Clinical and radiologic outcomes of Lima ProMade custom 3D-printed glenoid components in primary and revision reverse total shoulder arthroplasty with severe glenoid bone loss: a minimum 2-year follow-up
- 30 May 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (10) , 2017-2026
Clinical and radiologic outcomes of Lima ProMade custom 3D-printed glenoid components in primary and revision reverse total shoulder arthroplasty with severe glenoid bone loss: a minimum 2-year follow-up
- Open Access
- 21 September 2022
- Published by Springer Nature
Early stability and clinical outcomes of the LIMA Hybrid Shoulder Replacement assessed using x-ray analysis, clinical follow-up and patient-reported outcomes
- 21 September 2022
- Published by Springer Nature
Open AccessEarly stability and clinical outcomes of the LIMA Hybrid Shoulder Replacement assessed using x-ray analysis, clinical follow-up and patient-reported outcomes