A Fault-Location-Based Accelerated Trip Scheme for Distance Protection in IBR-Integrated Networks
Open Access
- 20 October 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 181313-181322
Abstract
Distance relays exhibit delayed operation for faults occurring near both ends of a transmission line. Numerous accelerated trip (AT) solutions have been introduced to address this limitation, including pilot and non-pilot types. Non-pilot methods are receiving particular attention due to their independence from communication infrastructure. However, the effectiveness of these methods is limited in the presence of inverter-based resources (IBRs), as their fault responses differ substantially from those of synchronous generators. This paper proposes a novel non-pilot AT scheme for distance relays, tailored explicitly for line-to-line and line-to-line-to-ground faults in IBR-integrated networks. At its core lies an innovative fault-location approach for pre- and post-remote circuit breaker operation (RCBO) conditions. The approach depends solely on locally measured voltage and current signals and is inherently insensitive to the fault current characteristics. By utilizing the estimated fault locations and their variations, the proposed scheme detects RCBO and issues either an accelerated or a time-delayed trip command. Extensive simulations in PSCAD/EMTDC under diverse fault and system conditions validate its fault location accuracy, significantly reduced fault-clearing time, and robustness against the distinctive behavior of IBRs.Keywords
This publication has 25 references indexed in Scilit:
- Fault Type Classification in the Presence of Inverter-Based Resources: Review, Challenges, and Future WorksIEEE Access, 2025
- Novel second zone acceleration technique for distance relay utilizing sequence voltagesElectric Power Systems Research, 2024
- A novel accelerated trip scheme for AC grids based on open-switching traveling wavesInternational Journal of Electrical Power & Energy Systems, 2024
- Non-pilot accelerated trip for distance relays using total relative reactance change in Zone IIElectric Power Systems Research, 2023
- Acceleration of distance protection second zone: A non-pilot method based on the healthy phases dataElectric Power Systems Research, 2022
- Power System Stability With a High Penetration of Inverter-Based ResourcesProceedings of the IEEE, 2022
- IEEE Standard for Interconnection and Interoperability of Inverter-Based Resources (IBRs) Interconnecting with Associated Transmission Electric Power Systems2022
- High-speed auxiliary fault location element for distance relays in double-circuit linesElectric Power Systems Research, 2021
- Non-communication protection of parallel transmission lines using breakers open-switching travelling wavesIET Generation, Transmission & Distribution, 2012
- Dual current control scheme for PWM converter under unbalanced input voltage conditionsIEEE Transactions on Industrial Electronics, 1999