Mahdi Davarpanah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mahdi Davarpanah has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Majid Sanaye-Pasand
University of Tehran
7 shared publications - Moein Abedini
University of Tehran
7 shared publications - Reza Bekhradian
School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
4 shared publications - Farrokh Aminifar
Quanta Technology, LLC, Raleigh, United States
3 shared publications - Hamidreza Daryabar
School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
3 shared publications - Mohammad Shahidehpour
Illinois Institute of Technology
2 shared publications
Latest Publications
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (3) , 1493-1503
Deriving a Novel Equivalent Circuit to Capture Current Transformer Behavior Under Partial Saturation Phenomena Caused by Stray Fluxes
Presence of the external stray fluxes or eccentric installation of the primary conductor results in non-uniform flux distribution in the current transformer (CT) core. This causes saturation in some portions of the core, called partial saturation (PS) phenomenon. Moreover, the saturation of the entire core results in CT total saturation. In both cases, CT accuracy decreases, which can result in measurement and tariff meter inaccuracy as well as protective relay maloperation. In this article, a novel electrical equivalent circuit is derived to accurately model stray fluxes and eccentricity of the primary conductor effects on partial and total saturation phenomena. The method is based on dividing the CT iron core into some portions. Each portion is then modeled with a nonlinear inductance within the equivalent circuit. This approach accurately captures the behavior of the CT under the PS phenomenon. The method demonstrates remarkable accuracy, closely mirroring outcomes obtained through finite element method (FEM) simulations and practical experimentations, and shows a significant speedup by a factor of 100 compared to the FEM. The ability to model stray fluxes and PS phenomena, along with high efficiency, makes the new circuit model very useful and necessary for implementing in electromagnetic transient program simulation tools.
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (3) , 1493-1503
Deriving a Novel Equivalent Circuit to Capture Current Transformer Behavior Under Partial Saturation Phenomena Caused by Stray Fluxes
Presence of the external stray fluxes or eccentric installation of the primary conductor results in non-uniform flux distribution in the current transformer (CT) core. This causes saturation in some portions of the core, called partial saturation (PS) phenomenon. Moreover, the saturation of the entire core results in CT total saturation. In both cases, CT accuracy decreases, which can result in measurement and tariff meter inaccuracy as well as protective relay maloperation. In this article, a novel electrical equivalent circuit is derived to accurately model stray fluxes and eccentricity of the primary conductor effects on partial and total saturation phenomena. The method is based on dividing the CT iron core into some portions. Each portion is then modeled with a nonlinear inductance within the equivalent circuit. This approach accurately captures the behavior of the CT under the PS phenomenon. The method demonstrates remarkable accuracy, closely mirroring outcomes obtained through finite element method (FEM) simulations and practical experimentations, and shows a significant speedup by a factor of 100 compared to the FEM. The ability to model stray fluxes and PS phenomena, along with high efficiency, makes the new circuit model very useful and necessary for implementing in electromagnetic transient program simulation tools.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 138992-139002
Image-Based Detection of Short-Circuit Faults in Drive-Fed Induction Motors: A Comparative Study of Current and Vibration Signatures
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 138992-139002
Open AccessImage-Based Detection of Short-Circuit Faults in Drive-Fed Induction Motors: A Comparative Study of Current and Vibration Signatures
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Industry Applications
- Vol. 7, 848-866
Coordinated Tuning of Type 4 Wind Turbines and Power System Stabilizers in Wind Power Integrated Grids
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Industry Applications
- Vol. 7, 848-866
Open AccessCoordinated Tuning of Type 4 Wind Turbines and Power System Stabilizers in Wind Power Integrated Grids
- Open Access
- 20 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 181313-181322
A Fault-Location-Based Accelerated Trip Scheme for Distance Protection in IBR-Integrated Networks
Distance relays exhibit delayed operation for faults occurring near both ends of a transmission line. Numerous accelerated trip (AT) solutions have been introduced to address this limitation, including pilot and non-pilot types. Non-pilot methods are receiving particular attention due to their independence from communication infrastructure. However, the effectiveness of these methods is limited in the presence of inverter-based resources (IBRs), as their fault responses differ substantially from those of synchronous generators. This paper proposes a novel non-pilot AT scheme for distance relays, tailored explicitly for line-to-line and line-to-line-to-ground faults in IBR-integrated networks. At its core lies an innovative fault-location approach for pre- and post-remote circuit breaker operation (RCBO) conditions. The approach depends solely on locally measured voltage and current signals and is inherently insensitive to the fault current characteristics. By utilizing the estimated fault locations and their variations, the proposed scheme detects RCBO and issues either an accelerated or a time-delayed trip command. Extensive simulations in PSCAD/EMTDC under diverse fault and system conditions validate its fault location accuracy, significantly reduced fault-clearing time, and robustness against the distinctive behavior of IBRs.
- 20 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 181313-181322
Open AccessA Fault-Location-Based Accelerated Trip Scheme for Distance Protection in IBR-Integrated Networks
Distance relays exhibit delayed operation for faults occurring near both ends of a transmission line. Numerous accelerated trip (AT) solutions have been introduced to address this limitation, including pilot and non-pilot types. Non-pilot methods are receiving particular attention due to their independence from communication infrastructure. However, the effectiveness of these methods is limited in the presence of inverter-based resources (IBRs), as their fault responses differ substantially from those of synchronous generators. This paper proposes a novel non-pilot AT scheme for distance relays, tailored explicitly for line-to-line and line-to-line-to-ground faults in IBR-integrated networks. At its core lies an innovative fault-location approach for pre- and post-remote circuit breaker operation (RCBO) conditions. The approach depends solely on locally measured voltage and current signals and is inherently insensitive to the fault current characteristics. By utilizing the estimated fault locations and their variations, the proposed scheme detects RCBO and issues either an accelerated or a time-delayed trip command. Extensive simulations in PSCAD/EMTDC under diverse fault and system conditions validate its fault location accuracy, significantly reduced fault-clearing time, and robustness against the distinctive behavior of IBRs.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2661-2672
Innovative Loss of Field Protection Algorithm for Small-Scale Synchronous Generators
Although conventional loss of field (LOF) protection schemes, especially impedance-based ones, are widely used for large-scale synchronous generators, they may not provide proper performance for small-scale synchronous generators (SSSGs) due to various concerns including, (i) large tripping time for unrecoverable LOF (ULOF) which may lead to severe voltage drop and stalling of nearby induction motors, (ii) LOF function maloperation during islanding events, and (iii) LOF function maloperation during recoverable LOF events. To resolve these issues, a new adaptive LOF protection logic is proposed for SSSGs. After ULOF events, the automatic voltage regulator (AVR) output gradually increases, while the SSSG internal voltage does not considerably increase. Based on this principle, some measurable or easily calculable parameters, including AVR output and SSSG internal voltage, are adopted to discriminate ULOF from other disturbances. Meanwhile, the proposed logic is wisely equipped with an adaptive time delay to prevent stalling of nearby induction motors and enhance operation speed during ULOF. Performance of the proposed algorithm is evaluated under various LOF and islanding events as well as short circuits. Obtained promising results confirm desirable performance of the proposed approach. Besides, compared to the impedance-based method, the proposed adaptive time delay considerably improves the security and reliability.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2661-2672
Innovative Loss of Field Protection Algorithm for Small-Scale Synchronous Generators
Although conventional loss of field (LOF) protection schemes, especially impedance-based ones, are widely used for large-scale synchronous generators, they may not provide proper performance for small-scale synchronous generators (SSSGs) due to various concerns including, (i) large tripping time for unrecoverable LOF (ULOF) which may lead to severe voltage drop and stalling of nearby induction motors, (ii) LOF function maloperation during islanding events, and (iii) LOF function maloperation during recoverable LOF events. To resolve these issues, a new adaptive LOF protection logic is proposed for SSSGs. After ULOF events, the automatic voltage regulator (AVR) output gradually increases, while the SSSG internal voltage does not considerably increase. Based on this principle, some measurable or easily calculable parameters, including AVR output and SSSG internal voltage, are adopted to discriminate ULOF from other disturbances. Meanwhile, the proposed logic is wisely equipped with an adaptive time delay to prevent stalling of nearby induction motors and enhance operation speed during ULOF. Performance of the proposed algorithm is evaluated under various LOF and islanding events as well as short circuits. Obtained promising results confirm desirable performance of the proposed approach. Besides, compared to the impedance-based method, the proposed adaptive time delay considerably improves the security and reliability.
- 12 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (3) , 2160-2169
A Novel Framework for Operation of Capacitor Banks in Non/Semi/Fully-Automated Distribution Networks
Nowadays, distribution systems have different levels of automation due to the need for massive investment. The optimal operation of capacitor banks (CBs) is a widely-used approach to improve the performance of these systems. Therefore, the optimal operation of CBs in distribution systems with any level of automation is essential. This paper introduces a novel framework for the operation of CBs in the non/semi/fully-automated distribution networks based on two timescales of day-ahead and near-to-real-time applications. In this framework, the linear current injection power flow method to properly study CB effects on the system is developed, including i) modeling vector group transformer, ii) modeling induction motors, iii) plotting the PV curve of motor loads as indices to assess the efficiency of CB on the voltage system, and iv) developing a fast power flow method with a low computational burden. Besides, the optimization problem of CBs control as the core of the proposed framework is reformulated, considering the level of network automation. The accuracy of the developed framework is evaluated on the IEEE 37-bus and 123-bus test systems. The obtained results verify the efficiency and superiority of the proposed framework.
- 12 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (3) , 2160-2169
A Novel Framework for Operation of Capacitor Banks in Non/Semi/Fully-Automated Distribution Networks
Nowadays, distribution systems have different levels of automation due to the need for massive investment. The optimal operation of capacitor banks (CBs) is a widely-used approach to improve the performance of these systems. Therefore, the optimal operation of CBs in distribution systems with any level of automation is essential. This paper introduces a novel framework for the operation of CBs in the non/semi/fully-automated distribution networks based on two timescales of day-ahead and near-to-real-time applications. In this framework, the linear current injection power flow method to properly study CB effects on the system is developed, including i) modeling vector group transformer, ii) modeling induction motors, iii) plotting the PV curve of motor loads as indices to assess the efficiency of CB on the voltage system, and iv) developing a fast power flow method with a low computational burden. Besides, the optimization problem of CBs control as the core of the proposed framework is reformulated, considering the level of network automation. The accuracy of the developed framework is evaluated on the IEEE 37-bus and 123-bus test systems. The obtained results verify the efficiency and superiority of the proposed framework.
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (3) , 2085-2095
Three-Terminal Lines Fault Location Using Two Main Terminals Data in the Presence of Renewable Energy Sources
Penetration of renewable energy sources (RESs) in power systems is increased considerably and fault location algorithms face considerable problems with the presence of RESs. Also, the third terminal of three-terminal lines is expanded as a cost-effective solution to energize the remote areas of medium voltage (MV) systems, while its data may not be measured and easily available. In addition, in cases where this data is obtainable, due to the excessive harmonics of the inverter-based resources (IBRs) in that terminal, the measured data includes high error. Therefore, providing a method for fault location in three-terminal lines in the presence of RESs is challenging. This paper proposes an accurate method to identify the fault location on these lines incorporating RESs without requiring the third terminal data. Due to current transformers saturation and transient response of capacitive voltage transformers, the fault location based on the faulted phase data contains significant errors. The proposed method combines both the faulty and healthy phases data to improve the accuracy of fault location. Its performance is evaluated on a MV system for different scenarios including various fault resistances, locations and types, and third terminal integration of RESs. The obtained results confirm superiority of the proposed method.
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (3) , 2085-2095
Three-Terminal Lines Fault Location Using Two Main Terminals Data in the Presence of Renewable Energy Sources
Penetration of renewable energy sources (RESs) in power systems is increased considerably and fault location algorithms face considerable problems with the presence of RESs. Also, the third terminal of three-terminal lines is expanded as a cost-effective solution to energize the remote areas of medium voltage (MV) systems, while its data may not be measured and easily available. In addition, in cases where this data is obtainable, due to the excessive harmonics of the inverter-based resources (IBRs) in that terminal, the measured data includes high error. Therefore, providing a method for fault location in three-terminal lines in the presence of RESs is challenging. This paper proposes an accurate method to identify the fault location on these lines incorporating RESs without requiring the third terminal data. Due to current transformers saturation and transient response of capacitive voltage transformers, the fault location based on the faulted phase data contains significant errors. The proposed method combines both the faulty and healthy phases data to improve the accuracy of fault location. Its performance is evaluated on a MV system for different scenarios including various fault resistances, locations and types, and third terminal integration of RESs. The obtained results confirm superiority of the proposed method.
- 12 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (1) , 388-399
Innovative Load Shedding Scheme to Restore Synchronous Generator-Based Microgrids During FIDVR
Fault induced voltage recovery (FIDVR) phenomenon may occur in microgrids ($\mu $ Gs) and distribution systems due to the induction motors (IMs) behavior after system voltage sags especially short circuit faults. For the case that motors reaccelerate, system voltage may recover to its nominal value after few seconds. However, it may remain low during motor stalling condition, which result in unstable (non-recoverable) FIDVR. In this paper, an adaptive load shedding scheme is proposed to mitigate unstable FIDVR in$\mu $ Gs containing synchronous dispersed generators (SDGs) to enhance system dynamic behavior. Derivative of the imaginary part of equivalent admittance seen from the distribution feeders with respect to time is utilized to discriminate stable FIDVR from unstable ones. In addition, a new criterion is proposed to determine SDG stability margin during the FIDVR phenomenon. Then, a new load shedding scheme is presented based on the proposed SDG stability margin and IM reacceleration index. Moreover, the load shedding time delay is adaptively calculated based on motor reacceleration time. Performance of the proposed method is evaluated by comprehensive simulation studies on two realistic networks. These investigations fairly reveal security and reliability of the proposed method in various conditions.- 12 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (1) , 388-399
Innovative Load Shedding Scheme to Restore Synchronous Generator-Based Microgrids During FIDVR
Fault induced voltage recovery (FIDVR) phenomenon may occur in microgrids ($\mu $ Gs) and distribution systems due to the induction motors (IMs) behavior after system voltage sags especially short circuit faults. For the case that motors reaccelerate, system voltage may recover to its nominal value after few seconds. However, it may remain low during motor stalling condition, which result in unstable (non-recoverable) FIDVR. In this paper, an adaptive load shedding scheme is proposed to mitigate unstable FIDVR in$\mu $ Gs containing synchronous dispersed generators (SDGs) to enhance system dynamic behavior. Derivative of the imaginary part of equivalent admittance seen from the distribution feeders with respect to time is utilized to discriminate stable FIDVR from unstable ones. In addition, a new criterion is proposed to determine SDG stability margin during the FIDVR phenomenon. Then, a new load shedding scheme is presented based on the proposed SDG stability margin and IM reacceleration index. Moreover, the load shedding time delay is adaptively calculated based on motor reacceleration time. Performance of the proposed method is evaluated by comprehensive simulation studies on two realistic networks. These investigations fairly reveal security and reliability of the proposed method in various conditions.- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 4145-4153
Resolving Current Transformer Partial Saturation Problem: An Analytical Approach to Design the Flux Equalizing Winding
Stray fluxes passing through the current transformer (CT) core produced by adjacent bus-bars and conductors or eccentric installation of primary conductors results in asymmetric magnetic flux distribution along the core. This may lead to exceeding the magnetic flux from its appropriate saturation level in some parts of the core, which is called partial saturation (PS) phenomenon. Under such a condition, CT error increases, and some relays maloperations may take place. This paper proposes a novel analytical approach to design flux equalizing winding (EW) for resolving such a problem. Moreover, PS occurrence in a core balance CT (CBCT) is analyzed using the finite element method (FEM), and its negative influence on a sensitive earth fault (SEF) relay is scrutinized as a case study. Simulation studies reveal that the proposed approach can prevent PS-related undesirable effects in a real power system.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 4145-4153
Resolving Current Transformer Partial Saturation Problem: An Analytical Approach to Design the Flux Equalizing Winding
Stray fluxes passing through the current transformer (CT) core produced by adjacent bus-bars and conductors or eccentric installation of primary conductors results in asymmetric magnetic flux distribution along the core. This may lead to exceeding the magnetic flux from its appropriate saturation level in some parts of the core, which is called partial saturation (PS) phenomenon. Under such a condition, CT error increases, and some relays maloperations may take place. This paper proposes a novel analytical approach to design flux equalizing winding (EW) for resolving such a problem. Moreover, PS occurrence in a core balance CT (CBCT) is analyzed using the finite element method (FEM), and its negative influence on a sensitive earth fault (SEF) relay is scrutinized as a case study. Simulation studies reveal that the proposed approach can prevent PS-related undesirable effects in a real power system.