Teleoperation of Steerable Flexible Needles by Combining Kinesthetic and Vibratory Feedback
- 24 September 2014
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 7 (4) , 551-556
Abstract
Needle insertion in soft-tissue is a minimally invasive surgical procedure that demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and responsibility, autonomous robotic control is often not desirable. Therefore, it is necessary to focus also on techniques enabling clinicians to directly control the motion of the surgical tools. In this work, we address that challenge and present a novel teleoperated robotic system able to steer flexible needles. The proposed system tracks the position of the needle using an ultrasound imaging system and computes needle's ideal position and orientation to reach a given target. The master haptic interface then provides the clinician with mixed kinesthetic-vibratory navigation cues to guide the needle toward the computed ideal position and orientation. Twenty participants carried out an experiment of teleoperated needle insertion into a soft-tissue phantom, considering four different experimental conditions. Participants were provided with either mixed kinesthetic vibratory feedback or mixed kinesthetic-visual feedback. Moreover, we considered two different ways of computing ideal position and orientation of the needle: with or without set-points. Vibratory feedback was found more effective than visual feedback in conveying navigation cues, with a mean targeting error of 0.72 mm when using set-points, and of 1.10 mm without set-points.Keywords
Funding Information
- Netherlands Organization for Scientific Research (11204)
- European Union Seventh Framework Programme (FP7/2007-2013)
This publication has 22 references indexed in Scilit:
- Experimental evaluation of ultrasound-guided 3D needle steering in biological tissueInternational Journal of Computer Assisted Radiology and Surgery, 2014
- Two Finger Grasping Simulation with Cutaneous and Kinesthetic Force Feedback2012
- VerroTouch: High-Frequency Acceleration Feedback for Telerobotic Surgery2010
- Using a Fingertip Tactile Device to Substitute Kinesthetic Feedback in Haptic Interaction2010
- Vibrotactile perception: examining the coding of vibrations and the just noticeable difference under various conditionsMultimedia Systems, 2007
- Needle insertion into soft tissue: A surveyMedical Engineering & Physics, 2006
- Waypoint navigation with a vibrotactile waist beltACM Transactions on Applied Perception, 2005
- The hands-on orthopaedic robot "acrobot": early clinical trials of total knee replacement surgeryIEEE Transactions on Robotics and Automation, 2003
- Operator Performance in Surgical TelemanipulationPRESENCE: Virtual and Augmented Reality, 2001
- Semi-active guiding systems in surgery. A two-dof prototype of the passive arm with dynamic constraints (PADyC)Mechatronics, 1996