Estimation of the wear volume after total hip replacement: A simple access to geometrical concepts
Authors:
- 13 June 2007
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 30 (3) , 373-379
Abstract
Various formulas have been proposed to calculate the volume of prosthetic wear from the penetration depth of the head as assessed on plain radiographs, based on idealized, three-dimensional geometrical models of a prosthetic hip. However, for most published formulas no (or no simple) derivation is available and not all of them are correct. We describe a simple geometrical model that allows for transparent derivation of equations for various components of prosthetic wear volume and compare the calculated volumes with those obtained from published equations. These components are: (1) a right generalized cylinder resulting from a linear shift of a half spherical part of the prosthetic head into the hemispherical cup, (2) an additional wedge that is "cut" from the cup and (3) the wear from an optional additional cylindrical portion of the cup. We emphasize that calculation of a three-dimensional wear volume from linear penetration depth should be based on a geometrical concept that is transparent and simple enough for clinical research, such as the one presented. The incorrect formula of Kabo et al. should be completely abandoned.Keywords
This publication has 26 references indexed in Scilit:
- Precision and Limitation of Measuring Two-dimensional Wear on Clinical RadiographsClinical Orthopaedics and Related Research, 2006
- Comparison of Femoral Head Penetration Using RSA and the Martell MethodClinical Orthopaedics and Related Research, 2006
- Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysisJournal of Orthopaedic Science, 2003
- Wear and Periprosthetic OsteolysisClinical Orthopaedics and Related Research, 2001
- Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: A survey of 8 reports in the literatureActa Orthopaedica, 2001
- The effect of joint loading on acetabular wear measurement in total hip arthroplastyThe Journal of Arthroplasty, 2000
- Observations on the direction of wear in Charnley sockets retrieved at revisionThe Journal of Bone and Joint Surgery. British volume, 1998
- EBRA: A method to measure migration of acetabular componentsJournal of Biomechanics, 1995
- Measurement accuracy in acetabular cup wearThe Journal of Arthroplasty, 1995
- Radiographic calculation of anteversion in acetabular prosthesesThe Journal of Arthroplasty, 1995