RF Power, B1+rms, and SAR Variation with RF Coils, Conductive Metallic Implants, and Ionic Solutions at 1.5T and 3T
Open Access
Abstract
Currently, the time-averaged root-mean-square RF field (B1+rms) and specific absorption rate (SAR) are being evaluated to monitor and control RF-induced heating near conductive metallic implants, such as deep brain stimulation (DBS) leads, during MRI. However, experimental methods to assess the relationship between RF power, B1+rms, and SAR are lacking for RF coils, RF pulse sequences, metallic implants, and ionic solutions. A method is developed to evaluate the variation in RF power, B1+rms, and SAR with RF coils, metallic implants, and ionic solutions using phantoms consisting of water (H2O) and sodium chloride (NaCl) with four ionic concentrations (0, 1, 2, 3%), four metallic wavelengths (0, λ/2, λ, 2λ), two RF coils (body, head), transmit/receive (Tx/Rx) combinations, and five RF pulse flip angles (30, 45, 60, 75, 90 degrees) in two B0 fields (1.5T and 3T). The scanner-reported RF power and SAR varied with RF pulse sequences, RF coils, Tx/Rx, metallic implants, and ionic solutions, whereas B1+rms varied only with RF pulse sequences. The RF power, B1+rms, and SAR relationship depends on RF pulse sequences, RF coils, Tx/Rx, metallic implant wavelengths, and ionic concentrations. SAR (whole-body, head) scaled with RF power by absorption ratios (α) variable with experimental conditions.Keywords
This publication has 58 references indexed in Scilit:
- MRI‐Related Heating of Implants and Devices: A ReviewJournal of Magnetic Resonance Imaging, 2020
- MRI‐related FDA adverse event reports: A 10‐yr reviewMedical Physics, 2019
- Dielectric materials in magnetic resonanceConcepts in Magnetic Resonance Part A, 2011
- Effect of the extracranial deep brain stimulation lead on radiofrequency heating at 9.4 Tesla (400.2 MHz)Journal of Magnetic Resonance Imaging, 2010
- An efficient method for electrical conductivity measurement in the RF rangeConcepts in Magnetic Resonance Part B, 2010
- Insight into RF power requirements and B1 field homogeneity for human MRI via rigorous FDTD approachJournal of Magnetic Resonance Imaging, 2007
- Deep brain stimulation for Parkinson's disease: Surgical issuesMovement Disorders, 2006
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging–related heating at 1.5 teslaJournal of Magnetic Resonance Imaging, 2002
- Neurostimulators: Potential for excessive heating of deep brain stimulation electrodes during magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2001