    RF Power, B1+rms, and SAR Variation with RF Coils, Conductive Metallic Implants, and Ionic Solutions at 1.5T and 3T

    by David H. Gultekin

    Currently, the time-averaged root-mean-square RF field (B1+rms) and specific absorption rate (SAR) are being evaluated to monitor and control RF-induced heating near conductive metallic implants, such as deep brain stimulation (DBS) leads, during MRI. However, experimental methods to assess the relationship between RF power, B1+rms, and SAR are lacking for RF coils, RF pulse sequences, metallic implants, and ionic solutions. A method is developed to evaluate the variation in RF power, B1+rms, and SAR with RF coils, metallic implants, and ionic solutions using phantoms consisting of water (H2O) and sodium chloride (NaCl) with four ionic concentrations (0, 1, 2, 3%), four metallic wavelengths (0, λ/2, λ, 2λ), two RF coils (body, head), transmit/receive (Tx/Rx) combinations, and five RF pulse flip angles (30, 45, 60, 75, 90 degrees) in two B0 fields (1.5T and 3T). The scanner-reported RF power and SAR varied with RF pulse sequences, RF coils, Tx/Rx, metallic implants, and ionic solutions, whereas B1+rms varied only with RF pulse sequences. The RF power, B1+rms, and SAR relationship depends on RF pulse sequences, RF coils, Tx/Rx, metallic implant wavelengths, and ionic concentrations. SAR (whole-body, head) scaled with RF power by absorption ratios (α) variable with experimental conditions.

  • Open Access

    Reply to “Comments on ‘Experimental Evaluation of Relationship Between Radiofrequency Heating Near Implanted Conductive Devices, Scanner-Reported B 1+rms , and Transmit Power’”

    by David H. Gultekin, J. Thomas Vaughan, Devashish Shrivastava

    We describe the relationship between the RF-induced temperature change in a conductive metallic implant during the MRI, B1+rms, and RF power for RF pulse sequences, RF coils, and Tx/Rx combinations. We show that both temperature and RF power change with RF pulse sequences, RF coils, and Tx/Rx combinations, whereas B1+rms changes only with RF pulse sequences but not RF coils and Tx/Rx combinations. As a result, induced heating is associated with RF power propagation and loss corresponding to the B1+rms.


  • Open Access

    RF power, B 1+rms , and SAR variation with RF coils, conductive metallic implants, and ionic solutions at 1.5T and 3T

    by David H. Gultekin

    Background and Purpose: The magnetic resonance imaging (MRI) access for patients with active and passive implants is limited by radiofrequency (RF) safety. The time-averaged root-mean-square RF field (B 1+rms ) and specific absorption rate (SAR) are being evaluated to monitor and control RF-induced heating near conductive metallic implants, such as deep brain stimulation (DBS) leads, during MRI. However, experimental methods to assess the relationship between RF power, B 1+rms, and SAR are lacking for RF coils, metallic implants, and ionic solutions. Materials and Methods: A method is developed to evaluate the variation of RF power, B 1+rms, and SAR with RF coils, metallic implants, and ionic solutions using phantoms consisting of water (H 2 O) and sodium chloride (NaCl) with four ionic concentrations (0, 1, 2, 3 %), four metallic wavelengths (0, λ /2, λ , 2 λ ), two RF coils (body, head) transmit/receive (Tx/Rx) combinations, and five RF pulse flip angles (30°, 45°, 60°, 75°, 90°) in two B 0 fields (1.5T and 3T). Results: The scanner-reported RF power and SAR varied with RF pulse sequences, RF coils, Tx/Rx, metallic implants, and ionic solutions, whereas B 1+rms varied only with RF pulse sequences. The RF power, B 1+rms , and SAR relationship depends on RF pulse sequences, RF coils, Tx/Rx, implant wavelengths, and ionic concentrations. SAR (whole-body, head) scaled with RF power by absorption ratios (α) variable with experimental conditions. Conclusions: B 1+rms is insensitive to the presence and absence of conductive metallic implants and ionic solutions, implant wavelengths, ionic concentrations, RF coils, and Tx/Rx combinations. RF power must be monitored because scanner-reported SAR may vary unpredictably with experiments.

  • Open Access

    Experimental Evaluation of Relationship Between Radiofrequency Heating Near Implanted Conductive Devices, Scanner-Reported B1+rms, and Transmit Power

    by David H. Gultekin, John T. Vaughan, Devashish Shrivastava

    Time-varying radiofrequency (RF) fields necessary to perform magnetic resonance imaging (MRI) may induce excessive heating near implanted conductive medical devices during MRI. The time and space-averaged root-mean-square effective magnetic field (B1+rms) and specific absorption rate (SAR) have been proposed as metrics to control the RF-induced heating and avoid unintended thermal injury. We experimentally evaluate the relationship between the RF-induced heating near an implanted conductive medical device, scanner-reported B1+rms, and RF power. RF heating was measured near the electrodes of a commercial deep brain stimulation (DBS) lead placed in a tissue-equivalent gel phantom using fluoroptic temperature probes in a commercial 3T scanner during MRI. Four RF transmit/receive coil combinations were used: a circularly polarized head transmit/receive coil, a 20-channel head/neck, a 32-channel head, or a 64-channel head/neck receive-only coil with a whole-body transmit coil. RF heating was induced by a 2D GRE sequence using two RF pulse types (fast and normal), three flip angles (30°, 60°, and 90°), and turning the receive-only coils off/on. The scanner-reported B1+rms and RF power were recorded. Measurements show that temperature change correlates linearly with both RF power and square of B1+rms for each coil and combination. However, the variation in heating for various RF coils and combinations was much larger for B1+rms compared to RF power. Additional studies across other MR scanners are needed to better understand the extent of variation in RF-induced heating near implanted conductive devices as a function of scanner-reported B1+rms and RF power to develop conservative and reliable patient labeling.


  • Open Access

    An experimental evaluation of the relationship between the induced radiofrequency heating near an implanted conductive medical device during MRI, scanner reported B1+rms, and scanner reported average transmit power

    by David H. Gultekin, J. Thomas Vaughan, Devashish Shrivastava

    Background Time-varying radiofrequency (RF) fields necessary to perform magnetic resonance imaging (MRI) may induce excessive heating near implanted conductive medical devices during MRI. Both time and space-averaged root mean square of the effective magnetic field (B1+rms) and whole-body average specific absorption rate (SAR) (average RF power per unit body weight) have been proposed as metrics to control the induced heating and avoid unintended thermal injury. Purpose To evaluate the relationship between the induced RF heating near an implanted conductive medical device, scanner-reported B1+rms, and scanner-reported RF power. Methods RF heating was measured near the electrodes of deep brain stimulation (DBS) lead placed in a gel phantom using fluoroptic temperature probes in a commercial 3T scanner during MRI. Four transmit and receive RF coil combinations were used, a circularly polarized head transmit and receive coil, a 20-channel head and neck, a 32-channel head, or a 64-channel head and neck receive-only coil with a whole-body transmit coil. RF heating was induced by running a 2D GRE sequence with two RF pulse types (fast and normal) with varying flip angles of 30°, 60°, and 90° and by turning the receive-only coils off and on. The scanner-reported B1+rms and RF power were recorded. Results Measurements show that the induced temperature change correlated linearly with both the scanner-reported B1+rms and RF power for each coil combination. However, the variation in the induced heating for various RF coil combinations appeared to be much larger for the scanner-reported B1+rms compared to the scanner-reported RF power. Conclusion Additional studies across other MR scanners are needed to better understand the full extent of the variation in the induced heating near implanted conductive devices as a function of the scanner-reported B1+rms and RF power to develop conservative and reliable patient labeling.


  • Open Access

    Absorption of 5G Radiation in Brain Tissue as a Function of Frequency, Power and Time

    by David H. Gultekin, Peter H. Siegel

    The rapid release of 5G wireless communications networks has spurred renewed concerns regarding the interactions of higher radiofrequency (RF) radiation with living species. We examine RF exposure and absorption in ex vivo bovine brain tissue and a brain simulating gel at three frequencies: 1.9 GHz, 4 GHz and 39 GHz that are relevant to current (4G), and upcoming (5G) spectra. We introduce a highly sensitive thermal method for the assessment of radiation exposure, and derive experimentally, accurate relations between the temperature rise ( $\Delta T$ ), specific absorption rate (SAR) and the incident power density ( $F$ ), and tabulate the coefficients, $\Delta T/\Delta F$ and $\Delta $ (SAR)/ $\Delta F$ , as a function of frequency, depth and time. This new method provides both $\Delta T$ and SAR applicable to the frequency range below and above 6 GHz as shown at 1.9, 4 and 39 GHz, and demonstrates the most sensitive experimental assessment of brain tissue exposure to millimeter-wave radiation to date, with a detection limit of 1 mW. We examine the beam penetration, absorption and thermal diffusion at representative 4G and 5G frequencies and show that the RF heating increases rapidly with frequency due to decreasing RF source wavelength and increasing power density with the same incident power and exposure time. We also show the temperature effects of continuous wave, rapid pulse sequences and single pulses with varying pulse duration, and we employ electromagnetic modeling to map the field distributions in the tissue. Finally, using this new methodology, we measure the thermal diffusivity of ex vivo bovine brain tissue experimentally.


  • Regional Chemotherapy for Unresectable Intrahepatic Cholangiocarcinoma: A Potential Role for Dynamic Magnetic Resonance Imaging as an Imaging Biomarker and a Survival Update from Two Prospective Clinical Trials

    by Ioannis T. Konstantinidis, Richard K. G. Do, David H. Gultekin, Mithat Gönen, Lawrence H. Schwartz, Yuman Fong, Peter J. Allen, Michael I. D’aNgelica, Ronald P. DeMatteo, David S. Klimstra, et al.

    Background For patients with unresectable intrahepatic cholangiocarcinoma (ICC), treatment options are limited and survival is poor. This study summarizes the long-term outcome of two previously...


  • Prognostic Aspects of DCE-MRI in Recurrent Rectal Cancer

    by M. J. Gollub, K. Cao, D. H. Gultekin, D. Kuk, M. Gonen, M. Sohn, L. H. Schwartz, M. R. Weiser, L. K. Temple, G. M. Nash, et al.

    To explore whether pre-reoperative dynamic contrast-enhanced (DCE)-MRI findings correlate with clinical outcome in patients who undergo surgical treatment for recurrent rectal carcinoma.


  • Multiparametric Prostate MR Imaging with T2-weighted, Diffusion-weighted, and Dynamic Contrast-enhanced Sequences: Are All Pulse Sequences Necessary to Detect Locally Recurrent Prostate Cancer after Radiation Therapy?

    by Olivio F. Donati, Sung Il Jung, Hebert Alberto Vargas, David H. Gultekin, Junting Zheng, Chaya S. Moskowitz, Hedvig Hricak, Michael J. Zelefsky, Oguz Akin

    We found that the best overall diagnostic accuracy and the highest interreader agreement for the detection of recurrent prostate cancer after radiation therapy were achieved with a combination of T... PurposeTo compare diagnostic accuracy of T2-weighted magnetic resonance (MR) imaging with that of multiparametric (MP) MR imaging combining T2-weighted imaging with diffusion-weighted (DW) MR imagi...


  • Open Access

    NMR imaging of cell phone radiation absorption in brain tissue

    by David H. Gultekin, Lothar Moeller

    A method is described for measuring absorbed electromagnetic energy radiated from cell phone antennae into ex vivo brain tissue. NMR images the 3D thermal dynamics inside ex vivo bovine brain tissue and equivalent gel under exposure to power and irradiation time-varying radio frequency (RF) fields. The absorbed RF energy in brain tissue converts into Joule heat and affects the nuclear magnetic shielding and the Larmor precession. The resultant temperature increase is measured by the resonance frequency shift of hydrogen protons in brain tissue. This proposed application of NMR thermometry offers sufficient spatial and temporal resolution to characterize the hot spots from absorbed cell phone radiation in aqueous media and biological tissues. Specific absorption rate measurements averaged over 1 mg and 10 s in the brain tissue cover the total absorption volume. Reference measurements with fiber optic temperature sensors confirm the accuracy of the NMR thermometry.