ECG Signal Quality Assessments of a Small Bipolar Single-Lead Wearable Patch Sensor
- 15 March 2022
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 13 (5) , 783-796
Abstract
Purpose There is an increasing clinical interest in the adoption of small single-lead wearable ECG sensors for continuous cardiac monitoring. The purpose of this work is to assess ECG signal quality of such devices compared to gold standard 12-lead ECG. Methods The ECG signal from a 1-lead patch was systematically compared to the 12-lead ECG device in thirty subjects to establish its diagnostic accuracy in terms of clinically relevant signal morphology, wave representation, fiducial markers and interval and wave duration. One minute ECG segments with good signal quality was selected for analysis and the features of ECG were manually annotated for comparative assessment. Results The patch showed closest similarity based on correlation and normalized root-mean-square error to the standard ECG leads I, II, \({\text {V}_3}\) and \({\text {V}_4}\). P-wave and QRS complexes in the patch showed sensitivity (Se) and positive predictive value (PPV) of at least 99.8% compared to lead II. T-wave representation showed Se and PPV of at least 99.9% compared to lead \({\text {V}_3}\) and \({\text {V}_4}\). Mean errors for onset and offset of the ECG waves, wave durations, and ECG intervals were within 2 samples based on 125Hz patch ECG sampling frequency. Conclusion This study demonstrates the diagnostic capability with similar morphological representation and reasonable timing accuracy of ECG signal from a patch sensor compared to 12-lead ECG. The advantages and limitations of small bipolar single-lead wearable patch sensor compared to 12-lead ECG are discussed in the context of relevant differences in ECG signal for clinical applications.
Keywords
This publication has 26 references indexed in Scilit:
- The effect of precordial lead displacement on ECG morphologyMedical & Biological Engineering & Computing, 2013
- Automatic detection of ECG electrode misplacement: a tale of two algorithmsPhysiological Measurement, 2012
- Ambulatory External Electrocardiographic MonitoringJACC, 2011
- Modulators of normal electrocardiographic intervals identified in a large electronic medical recordHeart Rhythm, 2011
- Best Electrode Locations for a Small Bipolar ECG Device: Signal Strength Analysis of Clinical DataAnnals of Biomedical Engineering, 2008
- The V-Quick patch versus the standard 12-lead ECG system: time is the essenceInternational Journal of Emergency Medicine, 2008
- Utility of Mobile Cardiac Outpatient Telemetry for the Diagnosis of Palpitations, Presyncope, Syncope, and the Assessment of Therapy EfficacyJournal of Cardiovascular Electrophysiology, 2007
- Clinical value of 12-lead electrocardiogram after successful reperfusion therapy for acute myocardial infarctionThe Lancet, 1997
- Heart rate variability: Standards of measurement, physiological interpretation, and clinical useEuropean Heart Journal, 1996
- Error measures for generalizing about forecasting methods: Empirical comparisonsInternational Journal of Forecasting, 1992