  • ECG Signal Quality Assessments of a Small Bipolar Single-Lead Wearable Patch Sensor

    by Paurakh Lal Rajbhandary, Gabriel Nallathambi, Nandakumar Selvaraj, Thang Tran, Olivier Colliou

    Purpose There is an increasing clinical interest in the adoption of small single-lead wearable ECG sensors for continuous cardiac monitoring. The purpose of this work is to assess ECG signal quality of such devices compared to gold standard 12-lead ECG. Methods The ECG signal from a 1-lead patch was systematically compared to the 12-lead ECG device in thirty subjects to establish its diagnostic accuracy in terms of clinically relevant signal morphology, wave representation, fiducial markers and interval and wave duration. One minute ECG segments with good signal quality was selected for analysis and the features of ECG were manually annotated for comparative assessment. Results The patch showed closest similarity based on correlation and normalized root-mean-square error to the standard ECG leads I, II, \({\text {V}_3}\) and \({\text {V}_4}\). P-wave and QRS complexes in the patch showed sensitivity (Se) and positive predictive value (PPV) of at least 99.8% compared to lead II. T-wave representation showed Se and PPV of at least 99.9% compared to lead \({\text {V}_3}\) and \({\text {V}_4}\). Mean errors for onset and offset of the ECG waves, wave durations, and ECG intervals were within 2 samples based on 125Hz patch ECG sampling frequency. Conclusion This study demonstrates the diagnostic capability with similar morphological representation and reasonable timing accuracy of ECG signal from a patch sensor compared to 12-lead ECG. The advantages and limitations of small bipolar single-lead wearable patch sensor compared to 12-lead ECG are discussed in the context of relevant differences in ECG signal for clinical applications.


  • Effect of Spectral Degradation and Spatio-Energy Correlation in X-Ray PCD for Imaging

    by Paurakh L. Rajbhandary, Scott S. Hsieh, Norbert J. Pelc

    Charge sharing, scatter and fluorescence events in a photon counting detector (PCD) can result in counting of a single incident photon in multiple neighboring pixels, each at a fraction of the true energy. This causes energy distortion and correlation of data across energy bins in neighboring pixels (spatio-energy correlation), with the severity depending on the detector pixel size and detector material. If a “macro-pixel” is formed by combining the counts from multiple adjacent small pixels, it will exhibit correlations across its energy bins. Understanding these effects can be crucial for detector design and for model based imaging applications. This study investigates the impact of these effects in basis material and effective monoenergetic estimates using the Cramer-Rao Lower Bound. To do so, we derive a correlation model for the multi-counting events. CdTe detectors with grids of pixels with side length of 250 μm, 500 μm, and 1 mm were compared, with binning of 4×4, 2×2, and 1×1 pixels, respectively, to keep the same net 1 mm2 aperture constant. The same flux was applied to each. The mean and covariance matrix of measured photon counts were derived analytically using spatio-energy response functions (SERF) precomputed from Monte Carlo simulations. Our results show that a 1 mm2 macro-pixel with 250×250 μm2 sub-pixels shows 35% higher standard deviation than a single 1 mm2 pixel for material-specific imaging, while the penalty for effective monoenergetic imaging is <10% compared to a single 1 mm2 pixel. Potential benefits of sub-pixels (higher spatial resolution and lower pulse pile-up effects) are important but were not investigated here.


  • Segmented targeted least squares estimator for material decomposition in multibin photon-counting detectors

    by Paurakh L. Rajbhandary, Scott S. Hsieh, Norbert J. Pelc

    We present a fast, noise-efficient, and accurate estimator for material separation using photon-counting x-ray detectors (PCXDs) with multiple energy bin capability. The proposed targeted least squares estimator (TLSE) is an improvement of a previously described A-table method by incorporating dynamic weighting that allows the variance to be closer to the Cramér–Rao lower bound (CRLB) throughout the operating range. We explore Cartesian and average-energy segmentation of the basis material space for TLSE and show that, compared with Cartesian segmentation, the average-energy method requires fewer segments to achieve similar performance. We compare the average-energy TLSE to other proposed estimators—including the gold standard maximum likelihood estimator (MLE) and the A-table—in terms of variance, bias, and computational efficiency. The variance and bias were simulated in the range of 0 to 6 cm of aluminum and 0 to 50 cm of water with Monte Carlo methods. The Average-energy TLSE achieves an average variance within 2% of the CRLB and mean absolute error of 3.68±0.06×10−6 cm. Using the same protocol, the MLE showed variance within 1.9% of the CRLB ratio and average absolute error of 3.10±0.06×10−6 cm but was 50 times slower in our implementations. Compared with the A-table method, TLSE gives a more homogenously optimal variance-to-CRLB ratio in the operating region. We show that variance in basis material estimates for TLSE is lower than that of the A-table method by as much as ∼36% in the peripheral region of operating range (thin or thick objects). The TLSE is a computationally efficient and fast method for material separation with PCXDs, with accuracy and precision comparable to the MLE.