William R. Ledoux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
William R. Ledoux has a total of 252 co-authors. Here are the top co-authors by number of shared publications:
Bruce J. Sangeorzan
RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound, Seattle, WA, USA
35 shared publications- Bruce J. Sangeorzan
VA Puget Sound Health Care System, Seattle, Washington
10 shared publications Jane B. Shofer
VA RR& D Center for Limb Loss and MoBility, Seattle, WA 98108, USA
9 shared publicationsShruti Pai
VA RR&D Center for Limb Loss and MoBility, Seattle, WA 98108
9 shared publicationsEric C. Whittaker
RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound, Seattle, WA, USA
8 shared publicationsJoseph M. Iaquinto
RR &D Ctr Limb Loss & MoBil CLiMB, Dept Vet Affairs, Seattle, WA USA
7 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 11 (3)
Advancing Prevention and Treatment of Ankle Osteoarthritis: A Translational Clinical Roadmap from the 2026 AOFAS/Arthritis Foundation Ankle Arthritis Think Tank
Ankle osteoarthritis (OA) is predominantly post-traumatic in origin. It differs in important ways biologically, mechanically, and clinically from hip and knee OA. Despite recognition of its long-term burden, treatment strategies for ankle OA remain largely reactive and centered on end-stage reconstruction. The Arthritis Foundation and the American Orthopaedic Foot & Ankle Society (AOFAS) co-sponsored an Ankle Arthritis Think Tank to address this deficiency in Napa, CA, on January 22, 2026. The focus was to solve patient frustration of limited treatment options and relatively poor outcomes when comparing to hip and knee osteoarthritis. The 2026 meeting brought together a multidisciplinary group of scientists and clinicians to present our current related state of knowledge and to define translational research priorities capable of advancing prevention and treatment of ankle OA within the next decade. Four structured sessions addressed topics relating to ankle OA: (1) Biologic and Biomechanical Pathogenesis, (2) Diagnostic and Management Challenges, (3) Therapeutic Strategies, and (4) Research Methodology. A moderated closing discussion focused on identifying actionable and fundable research pathways. Session presentations and discussion are synthesized here into a unified review.
- 1 July 2026
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 11 (3)
Open AccessAdvancing Prevention and Treatment of Ankle Osteoarthritis: A Translational Clinical Roadmap from the 2026 AOFAS/Arthritis Foundation Ankle Arthritis Think Tank
Ankle osteoarthritis (OA) is predominantly post-traumatic in origin. It differs in important ways biologically, mechanically, and clinically from hip and knee OA. Despite recognition of its long-term burden, treatment strategies for ankle OA remain largely reactive and centered on end-stage reconstruction. The Arthritis Foundation and the American Orthopaedic Foot & Ankle Society (AOFAS) co-sponsored an Ankle Arthritis Think Tank to address this deficiency in Napa, CA, on January 22, 2026. The focus was to solve patient frustration of limited treatment options and relatively poor outcomes when comparing to hip and knee osteoarthritis. The 2026 meeting brought together a multidisciplinary group of scientists and clinicians to present our current related state of knowledge and to define translational research priorities capable of advancing prevention and treatment of ankle OA within the next decade. Four structured sessions addressed topics relating to ankle OA: (1) Biologic and Biomechanical Pathogenesis, (2) Diagnostic and Management Challenges, (3) Therapeutic Strategies, and (4) Research Methodology. A moderated closing discussion focused on identifying actionable and fundable research pathways. Session presentations and discussion are synthesized here into a unified review.
- Open Access
- 24 May 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (6) , e70229
In Vivo Assessment of Distal Femur Fracture Motion via Weightbearing CT
Distal femur fractures have a significant risk of healing complications, with potentially suboptimal fracture motion. We developed an in vivo method of quantifying fracture motion to support translational research. Five men and one woman (age 48.3 ± 24.9 years; weight 79.8 ± 12.9 kg, mean ± SD) underwent non‐weightbearing and weightbearing CT following plate (4) or nail (2) fixation of distal femur fractures (AO/OTA 33) while recording static ground reaction forces. Subject‐specific models were generated, coordinate systems were established, and fragment poses were reconstructed to assess motion. Fracture motion was measurable and greater at the medial than the lateral aspects of fractures, with notable axial plane motion. Three‐dimensional (3D) displacement (mean ± standard deviation [SD]) was greater at the medial than lateral fracture (4.4 ± 2.6 vs. 3.5 ± 2.6 mm, p = 0.047), including mean proximal‐distal displacement at the medial fracture (2.0 ± 3.0 mm) versus lateral fracture (0.8 ± 3.2 mm, p = 0.030), and mean axial plane displacement at the medial (3.5 ± 1.6 mm) versus lateral (2.6 ± 1.6 mm, p = 0.009) fracture. Axial plane displacement was similar to proximal‐distal displacement at the medial ( p = 0.318) and lateral ( p = 0.488) fracture. 3D and axial plane displacement were moderately associated with load, while proximal‐distal displacement was minimally associated with load. Weightbearing magnitude only modestly explained intersubject differences in motion. This method allows exploration of relationships between fracture motion, fracture pattern, fixation, loading, and healing.
- 24 May 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (6) , e70229
Open AccessIn Vivo Assessment of Distal Femur Fracture Motion via Weightbearing CT
Distal femur fractures have a significant risk of healing complications, with potentially suboptimal fracture motion. We developed an in vivo method of quantifying fracture motion to support translational research. Five men and one woman (age 48.3 ± 24.9 years; weight 79.8 ± 12.9 kg, mean ± SD) underwent non‐weightbearing and weightbearing CT following plate (4) or nail (2) fixation of distal femur fractures (AO/OTA 33) while recording static ground reaction forces. Subject‐specific models were generated, coordinate systems were established, and fragment poses were reconstructed to assess motion. Fracture motion was measurable and greater at the medial than the lateral aspects of fractures, with notable axial plane motion. Three‐dimensional (3D) displacement (mean ± standard deviation [SD]) was greater at the medial than lateral fracture (4.4 ± 2.6 vs. 3.5 ± 2.6 mm, p = 0.047), including mean proximal‐distal displacement at the medial fracture (2.0 ± 3.0 mm) versus lateral fracture (0.8 ± 3.2 mm, p = 0.030), and mean axial plane displacement at the medial (3.5 ± 1.6 mm) versus lateral (2.6 ± 1.6 mm, p = 0.009) fracture. Axial plane displacement was similar to proximal‐distal displacement at the medial ( p = 0.318) and lateral ( p = 0.488) fracture. 3D and axial plane displacement were moderately associated with load, while proximal‐distal displacement was minimally associated with load. Weightbearing magnitude only modestly explained intersubject differences in motion. This method allows exploration of relationships between fracture motion, fracture pattern, fixation, loading, and healing.
- Open Access
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Durability and Offloading Performance of 3D-Printed Multilayer Lattice for Accommodative Insoles
Custom accommodative insoles fabricated from multilayer foams are the standard of care (SoC) for offloading elevated plantar pressures in individuals with diabetes at risk of foot ulceration. While SoC insoles have demonstrated short-term effectiveness, they are prone to permanent material deformation over time, reducing their offloading efficacy. Recent work has shown that 3D-printed multilayer lattice structures using elastomeric polyurethane (EPU) can match the mechanical properties of SoC foams and is effective in reducing plantar pressures. However, their long-term pressure offloading performance and durability have not been investigated. In this study, 3D-printed EPU multilayer lattice pucks and SoC multilayer foam pucks, with and without designed offloading regions, underwent one million cycles of sinusoidal compressive loading under both uniform and uneven loading conditions. Peak pressure (PP), pressure time integral (PTI), residual thickness, and elastic modulus were assessed at multiple timepoints throughout testing. Under uniform loading, both materials maintained stable PPs below the 200 kPa clinical threshold across one million cycles. Under uneven loading, SoC pucks exhibited progressive pressure increases and residual thickness reductions of up to 36%, while 3D-printed pucks maintained structural integrity with thickness reductions of 3% or less and demonstrated beneficial mechanical settling that reduced PP over time. Both materials with designed offloading regions effectively maintained PPs below 150 kPa throughout testing. These findings support 3D-printed multilayer lattice insole materials as a durable and effective long-term strategy for plantar pressure management in high-risk diabetic populations.
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDurability and Offloading Performance of 3D-Printed Multilayer Lattice for Accommodative Insoles
Custom accommodative insoles fabricated from multilayer foams are the standard of care (SoC) for offloading elevated plantar pressures in individuals with diabetes at risk of foot ulceration. While SoC insoles have demonstrated short-term effectiveness, they are prone to permanent material deformation over time, reducing their offloading efficacy. Recent work has shown that 3D-printed multilayer lattice structures using elastomeric polyurethane (EPU) can match the mechanical properties of SoC foams and is effective in reducing plantar pressures. However, their long-term pressure offloading performance and durability have not been investigated. In this study, 3D-printed EPU multilayer lattice pucks and SoC multilayer foam pucks, with and without designed offloading regions, underwent one million cycles of sinusoidal compressive loading under both uniform and uneven loading conditions. Peak pressure (PP), pressure time integral (PTI), residual thickness, and elastic modulus were assessed at multiple timepoints throughout testing. Under uniform loading, both materials maintained stable PPs below the 200 kPa clinical threshold across one million cycles. Under uneven loading, SoC pucks exhibited progressive pressure increases and residual thickness reductions of up to 36%, while 3D-printed pucks maintained structural integrity with thickness reductions of 3% or less and demonstrated beneficial mechanical settling that reduced PP over time. Both materials with designed offloading regions effectively maintained PPs below 150 kPa throughout testing. These findings support 3D-printed multilayer lattice insole materials as a durable and effective long-term strategy for plantar pressure management in high-risk diabetic populations.
- Open Access
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Predictive Performance of Static Plantar Pressure Measurements for Identifying High-Pressure Regions During Shod Walking
Foot ulceration is a serious complication of diabetes and associated with elevated plantar pressures during walking. Custom accommodative insoles are most effective when informed by dynamic pressure data; however, static pressure collection offers a faster and more clinically feasible alternative. The ability of static pressure measurements to predict dynamic high-pressure regions remains unclear and needs investigation.This study compared peak plantar pressure, sensor-level correlations, and predictive performance of static pressure thresholds from static in-shoe and static barefoot data relative to dynamic in-shoe data. Plantar pressures were collected from 31 feet in 18 participants with elevated dynamic in-shoe forefoot pressures. Dynamic high-pressure regions were defined as regions exceeding 200 kPa. Sensor-level correlations were calculated, and receiver operating characteristic curves were used to determine static thresholds. Agreement metrics, including Dice coefficient, sensitivity, and positive predictive value, were evaluated.Sensor-level Pearson and Spearman correlations were higher for static versus dynamic in-shoe data than for static barefoot comparisons (p<0.001). Static thresholds were 40.4 and 55.8 kPa for in-shoe and barefoot data respectively. Despite moderate to strong correlations, Dice coefficients were low, indicating minimal spatial overlap between static and dynamic high-pressure regions. High sensitivity with low positive predictive value demonstrated that static thresholds overestimated the location and extent of dynamic high-pressure regions.These findings indicate that static pressure measurements, despite improved clinical feasibility, cannot reliably identify dynamic in-shoe high-pressure regions. Insole design based on static pressures may lead to overly conservative offloading and reduced specificity, reinforcing the need for dynamic pressure data in clinical practice.
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPredictive Performance of Static Plantar Pressure Measurements for Identifying High-Pressure Regions During Shod Walking
Foot ulceration is a serious complication of diabetes and associated with elevated plantar pressures during walking. Custom accommodative insoles are most effective when informed by dynamic pressure data; however, static pressure collection offers a faster and more clinically feasible alternative. The ability of static pressure measurements to predict dynamic high-pressure regions remains unclear and needs investigation.This study compared peak plantar pressure, sensor-level correlations, and predictive performance of static pressure thresholds from static in-shoe and static barefoot data relative to dynamic in-shoe data. Plantar pressures were collected from 31 feet in 18 participants with elevated dynamic in-shoe forefoot pressures. Dynamic high-pressure regions were defined as regions exceeding 200 kPa. Sensor-level correlations were calculated, and receiver operating characteristic curves were used to determine static thresholds. Agreement metrics, including Dice coefficient, sensitivity, and positive predictive value, were evaluated.Sensor-level Pearson and Spearman correlations were higher for static versus dynamic in-shoe data than for static barefoot comparisons (p<0.001). Static thresholds were 40.4 and 55.8 kPa for in-shoe and barefoot data respectively. Despite moderate to strong correlations, Dice coefficients were low, indicating minimal spatial overlap between static and dynamic high-pressure regions. High sensitivity with low positive predictive value demonstrated that static thresholds overestimated the location and extent of dynamic high-pressure regions.These findings indicate that static pressure measurements, despite improved clinical feasibility, cannot reliably identify dynamic in-shoe high-pressure regions. Insole design based on static pressures may lead to overly conservative offloading and reduced specificity, reinforcing the need for dynamic pressure data in clinical practice.
- Open Access
- 19 March 2026
- Published by Wiley in Journal of Foot and Ankle Research
- Vol. 19 (1) , e70146
Effects of First Metatarsophalangeal Osteoarthritis on Plantar Pressures Across Multiple Activities
Background: The first metatarsophalangeal joint (MTPJ1) is one of the sites most often affected by osteoarthritis (OA). The condition contributes to activity restrictions and reduced quality of life along with biomechanical changes that affect the joint and beyond. Despite this, previous studies have presented limited evidence of alterations in plantar pressures during level walking. In this case‐control study, we hypothesized that activities that may stress the joint to a greater extent than standard gait may reveal greater differences in plantar pressures between those with MTPJ1 OA and healthy feet. Methods: Participants with MTPJ1 OA ( n = 22) and matched controls ( n = 21) were recruited for this study. All were asked to perform four activities while plantar pressures were measured: standing, walking, stair ascent, and heel raise. Analysis of discrete pressure variables at anatomical regions and statistical parametric mapping was used to determine if there were significant differences in pressures between MTPJ1 OA and control groups. Results: No differences were found for discrete variables across the activities, however, statistical parametric mapping revealed differences for the MTPJ1 OA group, including reduced loading under the distal first metatarsal head (60%–80% of stance), increased midfoot pressures at 70%–80% of stair ascent, and decreased lateral forefoot pressure during heel raise. Conclusion: MTPJ1 OA is associated with limited changes in plantar pressures across different activities. These regions of difference may be targeted by interventions such as foot orthotics as part of a personalized treatment program. Level of Evidence: Level IV, case control study.
- 19 March 2026
- Published by Wiley in Journal of Foot and Ankle Research
- Vol. 19 (1) , e70146
Open AccessEffects of First Metatarsophalangeal Osteoarthritis on Plantar Pressures Across Multiple Activities
Background: The first metatarsophalangeal joint (MTPJ1) is one of the sites most often affected by osteoarthritis (OA). The condition contributes to activity restrictions and reduced quality of life along with biomechanical changes that affect the joint and beyond. Despite this, previous studies have presented limited evidence of alterations in plantar pressures during level walking. In this case‐control study, we hypothesized that activities that may stress the joint to a greater extent than standard gait may reveal greater differences in plantar pressures between those with MTPJ1 OA and healthy feet. Methods: Participants with MTPJ1 OA ( n = 22) and matched controls ( n = 21) were recruited for this study. All were asked to perform four activities while plantar pressures were measured: standing, walking, stair ascent, and heel raise. Analysis of discrete pressure variables at anatomical regions and statistical parametric mapping was used to determine if there were significant differences in pressures between MTPJ1 OA and control groups. Results: No differences were found for discrete variables across the activities, however, statistical parametric mapping revealed differences for the MTPJ1 OA group, including reduced loading under the distal first metatarsal head (60%–80% of stance), increased midfoot pressures at 70%–80% of stair ascent, and decreased lateral forefoot pressure during heel raise. Conclusion: MTPJ1 OA is associated with limited changes in plantar pressures across different activities. These regions of difference may be targeted by interventions such as foot orthotics as part of a personalized treatment program. Level of Evidence: Level IV, case control study.
- 17 March 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (10) , 3415-3422
Characterization of the Ideal Speed of Sound for Plantar Soft Tissue Using Quasi-Simultaneous Ultrasound and Computed Tomography in Cadaveric Feet
Clinical ultrasound systems typically assume a speed of sound of 1540 m/s for reconstructing images. However, the speed of sound varies between tissues, and this assumption creates distortions and errors in representing the thickness of tissue structures. Quasi-simultaneous (i.e., taken subsequently without movement of the specimen) computed tomography (CT) and ultrasound scans at various speeds of sound (1480, 1540, 1600, and 1660 m/s) were taken at the calcaneus and the second metatarsal head for seven cadaveric feet. A speed of sound of 1600 m/s demonstrated the lowest bias with a mean signed error of - 0.06 mm for the calcaneus and - 0.19 mm for the second metatarsal head, while for 1540 m/s, the calcaneus had a bias of - 0.44 mm, and the second metatarsal head had a bias of - 0.67 mm. The CT-derived distance was used to estimate the ideal speed of sound by calculating the slope of the change in distance with the change in speed of sound and was found to be 1616.6 ± 76.5 m/s for the calcaneus and 1623.9 ± 63.6 m/s for the second metatarsal head. However, limitations in the use of cadavers, CT as the reference standard, and methodological assumptions in analysis limit the extent to which these findings can be generalized to in vivo conditions. This work suggests that using an assumed speed of sound greater than 1540 m/s may be more appropriate for imaging plantar soft tissue; however, additional in vivo studies are needed to corroborate this finding.
- 17 March 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (10) , 3415-3422
Characterization of the Ideal Speed of Sound for Plantar Soft Tissue Using Quasi-Simultaneous Ultrasound and Computed Tomography in Cadaveric Feet
Clinical ultrasound systems typically assume a speed of sound of 1540 m/s for reconstructing images. However, the speed of sound varies between tissues, and this assumption creates distortions and errors in representing the thickness of tissue structures. Quasi-simultaneous (i.e., taken subsequently without movement of the specimen) computed tomography (CT) and ultrasound scans at various speeds of sound (1480, 1540, 1600, and 1660 m/s) were taken at the calcaneus and the second metatarsal head for seven cadaveric feet. A speed of sound of 1600 m/s demonstrated the lowest bias with a mean signed error of - 0.06 mm for the calcaneus and - 0.19 mm for the second metatarsal head, while for 1540 m/s, the calcaneus had a bias of - 0.44 mm, and the second metatarsal head had a bias of - 0.67 mm. The CT-derived distance was used to estimate the ideal speed of sound by calculating the slope of the change in distance with the change in speed of sound and was found to be 1616.6 ± 76.5 m/s for the calcaneus and 1623.9 ± 63.6 m/s for the second metatarsal head. However, limitations in the use of cadavers, CT as the reference standard, and methodological assumptions in analysis limit the extent to which these findings can be generalized to in vivo conditions. This work suggests that using an assumed speed of sound greater than 1540 m/s may be more appropriate for imaging plantar soft tissue; however, additional in vivo studies are needed to corroborate this finding.
- 8 February 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 199, 113201
Quantifying differences in high-pressure region mapping between dynamic in-shoe and barefoot plantar pressure in diabetic subjects
- 8 February 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 199, 113201
Quantifying differences in high-pressure region mapping between dynamic in-shoe and barefoot plantar pressure in diabetic subjects
- 1 June 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 140 (1) , 104349
Verifying the accuracy and precision of foot bone segmentation from fan beam and cone beam computed tomography scans
Accurate segmentation of foot and ankle bones from computed tomography scans is an essential precursor to morphological comparison studies and model-based biplanar fluoroscopic tracking. Errors in modeling the bones may propagate into coordinate system definitions or affect arthrokinematic calculations. Cone beam computed tomography scanners with sensitive detectors offer a lower dose alternative to fan beam scanners, although with signal-to-noise ratio and tissue contrast tradeoffs. The primary aims of this study were to validate the accuracy of foot bone models (distal tibia, talus, calcaneus, navicular, first metatarsal, and proximal phalanx) generated using established semi-automatic segmentation techniques relative to ground truth laser scans of the dissected bone specimens and to compare the errors in models segmented from a fan beam scanner to those from a cone beam scanner. We found excellent between and within-operator intra-class correlation scores for segmentations (all > 0.90). Voxel-based metrics revealed small but significant differences between scanner types when comparing the Dice score and precision of segmentations, with cone beam having higher scores for nearly every metric type. Surface-based error data also revealed cone beam scans to be more accurate to the actual bone morphology despite having noisier images. The small isotropic voxels of the cone beam scanner produced bone models with errors averaging 0.43 ± 0.11 mm compared to the fan beam average of 0.74 ± 0.15 mm error across all bones. The findings suggest that voxel resolution is more critical than scanner type for modeling foot bones and that these segmentation techniques may overcome the limitations in cone beam scanners. These outcomes support the growing movement towards more widespread adoption of low-dose cone beam weight-bearing computed tomography imaging for 3D modeling of foot and ankle bones for clinical and research purposes.
- 1 June 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 140 (1) , 104349
Verifying the accuracy and precision of foot bone segmentation from fan beam and cone beam computed tomography scans
Accurate segmentation of foot and ankle bones from computed tomography scans is an essential precursor to morphological comparison studies and model-based biplanar fluoroscopic tracking. Errors in modeling the bones may propagate into coordinate system definitions or affect arthrokinematic calculations. Cone beam computed tomography scanners with sensitive detectors offer a lower dose alternative to fan beam scanners, although with signal-to-noise ratio and tissue contrast tradeoffs. The primary aims of this study were to validate the accuracy of foot bone models (distal tibia, talus, calcaneus, navicular, first metatarsal, and proximal phalanx) generated using established semi-automatic segmentation techniques relative to ground truth laser scans of the dissected bone specimens and to compare the errors in models segmented from a fan beam scanner to those from a cone beam scanner. We found excellent between and within-operator intra-class correlation scores for segmentations (all > 0.90). Voxel-based metrics revealed small but significant differences between scanner types when comparing the Dice score and precision of segmentations, with cone beam having higher scores for nearly every metric type. Surface-based error data also revealed cone beam scans to be more accurate to the actual bone morphology despite having noisier images. The small isotropic voxels of the cone beam scanner produced bone models with errors averaging 0.43 ± 0.11 mm compared to the fan beam average of 0.74 ± 0.15 mm error across all bones. The findings suggest that voxel resolution is more critical than scanner type for modeling foot bones and that these segmentation techniques may overcome the limitations in cone beam scanners. These outcomes support the growing movement towards more widespread adoption of low-dose cone beam weight-bearing computed tomography imaging for 3D modeling of foot and ankle bones for clinical and research purposes.
- 22 April 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 46 (5) , 484-494
Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans Osteotomy vs the Z-Osteotomy
Background: Progressive collapsing flatfoot deformity (PCFD) describes the pathologic form of a flatfoot (pes planus). Pes planus is often treated with lateral column–lengthening (LCL) procedures such as the Evans LCL. The Z-osteotomy has been explored as an alternative to the Evans LCL. We aim to compare bone position using radiographs and dynamic movement using a robotic gait simulator (RGS). Methods: Flatfoot was produced in cadaveric specimens by attenuating medial arch supporting ligaments and cyclically loading through the tibia. Clinical diagnostic measures from radiographs were used to assess foot shape. Each flatfoot underwent testing on the RGS with ground reaction forces scaled to 25% of the donor’s body weight and the stance phase simulated 6 times slower than physiologic gait (4.09 seconds). After flatfoot data collection, one foot in each pair received either the Evans LCL or Z-osteotomy. Postoperative radiographs were taken, and the feet were again tested on the RGS. Kinematic and kinetic data were collected and compared for both flatfoot and postsurgical trials. Results: All radiographic parameters were significantly ( P < .05) different after the flattening procedure, indicating arch collapse, forefoot abduction, and hindfoot eversion. The calcaneal pitch angle decreased, although not to the level seen in physiologic flatfoot. Changes toward arch restoration were seen in the radiographic parameters after surgeries, but there were no radiographic differences between surgery type for the number of specimens we tested (7 pairs). Peak pressure under the lateral forefoot significantly ( P < .05) increased after both surgeries but did not differ between procedures. Kinematic data only showed a few differences between the Evans and the Z-osteotomy. Conclusion: Radiographic evidence demonstrated that our model produced a mild flatfoot from neutrally aligned cadaveric specimens, and postsurgical feet showed significant improvement ( P < .05). Few differences between the surgical techniques were seen in the kinematic and kinetic data. Clinical Relevance: This cadaveric simulation study found that the Evans and Z-osteotomies are similar in their ability to biomechanically address mild flatfoot.
- 22 April 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 46 (5) , 484-494
Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans Osteotomy vs the Z-Osteotomy
Background: Progressive collapsing flatfoot deformity (PCFD) describes the pathologic form of a flatfoot (pes planus). Pes planus is often treated with lateral column–lengthening (LCL) procedures such as the Evans LCL. The Z-osteotomy has been explored as an alternative to the Evans LCL. We aim to compare bone position using radiographs and dynamic movement using a robotic gait simulator (RGS). Methods: Flatfoot was produced in cadaveric specimens by attenuating medial arch supporting ligaments and cyclically loading through the tibia. Clinical diagnostic measures from radiographs were used to assess foot shape. Each flatfoot underwent testing on the RGS with ground reaction forces scaled to 25% of the donor’s body weight and the stance phase simulated 6 times slower than physiologic gait (4.09 seconds). After flatfoot data collection, one foot in each pair received either the Evans LCL or Z-osteotomy. Postoperative radiographs were taken, and the feet were again tested on the RGS. Kinematic and kinetic data were collected and compared for both flatfoot and postsurgical trials. Results: All radiographic parameters were significantly ( P < .05) different after the flattening procedure, indicating arch collapse, forefoot abduction, and hindfoot eversion. The calcaneal pitch angle decreased, although not to the level seen in physiologic flatfoot. Changes toward arch restoration were seen in the radiographic parameters after surgeries, but there were no radiographic differences between surgery type for the number of specimens we tested (7 pairs). Peak pressure under the lateral forefoot significantly ( P < .05) increased after both surgeries but did not differ between procedures. Kinematic data only showed a few differences between the Evans and the Z-osteotomy. Conclusion: Radiographic evidence demonstrated that our model produced a mild flatfoot from neutrally aligned cadaveric specimens, and postsurgical feet showed significant improvement ( P < .05). Few differences between the surgical techniques were seen in the kinematic and kinetic data. Clinical Relevance: This cadaveric simulation study found that the Evans and Z-osteotomies are similar in their ability to biomechanically address mild flatfoot.
- 1 April 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (2)
Age, Mental Health, and Preoperative Radiographic Measurements Do Not Significantly Affect Clinically Meaningful Improvement After Surgery for End-Stage Ankle Arthritis
Background: Both total ankle arthroplasty and ankle arthrodesis are effective treatments for end-stage ankle arthritis. While studies have explored risk factors associated with complications, our aim was to guide management based on characteristics which may be associated with substantial patient-reported improvements without additional surgery and independent of surgery type. Methods: Data from a prospective multicenter cohort study conducted between May 2012 and May 2015 were analyzed. Preoperative and treatment factors including demographics, surgical history, radiographic parameters (coronal tilt, sagittal subluxation, and Kellgren-Lawrence grade), type of surgery, and comorbidities were collected. Patient-reported measures preoperative and postoperative: the Foot and Ankle Ability Measure subscale for activities of daily living (FAAM ADL) and pain were collected. Clinically meaningful improvement was defined as (1) an increase in the FAAM ADL score by the minimum clinically important difference and (2) absence of postoperative revisions during the follow-up period. A multivariable logistic regression model was performed adjusted for age, sex, body mass index, and surgery type to identify factors associated with clinically meaningful improvement. Results: Of the 517 patients who consented, 448 patients (86.7%) had a minimum of 4-year follow-up. Of the 448 patients, 331 (73.9%) met our criteria for clinically meaningful improvement. Female sex (odds ratio [OR] 2.1, confidence interval [CI, 1.3-3.4], p = 0.002) and no previous surgery (vs. surgery history, OR 1.7, CI [1.05-2.9], p = 0.030) were the strongest correlates adjusted for surgery type, although the association attenuated to below significance (p > 0.05) after multiple imputation of missing data. Mental health factors and preoperative radiographic measurements were not significantly associated with clinically meaningful improvement. Conclusions: Despite prior research to the contrary, age, mental health, and preoperative radiographic measurements such as coronal plane misalignment were not found to significantly affect outcomes after surgery while sex and no history of surgery were. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 1 April 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (2)
Age, Mental Health, and Preoperative Radiographic Measurements Do Not Significantly Affect Clinically Meaningful Improvement After Surgery for End-Stage Ankle Arthritis
Background: Both total ankle arthroplasty and ankle arthrodesis are effective treatments for end-stage ankle arthritis. While studies have explored risk factors associated with complications, our aim was to guide management based on characteristics which may be associated with substantial patient-reported improvements without additional surgery and independent of surgery type. Methods: Data from a prospective multicenter cohort study conducted between May 2012 and May 2015 were analyzed. Preoperative and treatment factors including demographics, surgical history, radiographic parameters (coronal tilt, sagittal subluxation, and Kellgren-Lawrence grade), type of surgery, and comorbidities were collected. Patient-reported measures preoperative and postoperative: the Foot and Ankle Ability Measure subscale for activities of daily living (FAAM ADL) and pain were collected. Clinically meaningful improvement was defined as (1) an increase in the FAAM ADL score by the minimum clinically important difference and (2) absence of postoperative revisions during the follow-up period. A multivariable logistic regression model was performed adjusted for age, sex, body mass index, and surgery type to identify factors associated with clinically meaningful improvement. Results: Of the 517 patients who consented, 448 patients (86.7%) had a minimum of 4-year follow-up. Of the 448 patients, 331 (73.9%) met our criteria for clinically meaningful improvement. Female sex (odds ratio [OR] 2.1, confidence interval [CI, 1.3-3.4], p = 0.002) and no previous surgery (vs. surgery history, OR 1.7, CI [1.05-2.9], p = 0.030) were the strongest correlates adjusted for surgery type, although the association attenuated to below significance (p > 0.05) after multiple imputation of missing data. Mental health factors and preoperative radiographic measurements were not significantly associated with clinically meaningful improvement. Conclusions: Despite prior research to the contrary, age, mental health, and preoperative radiographic measurements such as coronal plane misalignment were not found to significantly affect outcomes after surgery while sex and no history of surgery were. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.