Augmented Reality Image Guidance during Off-Pump Mitral Valve Replacement through the Guiraudon Universal Cardiac Introducer
Open Access
- 1 November 2010
- journal article
- research article
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 5 (6) , 430-438
Abstract
Objective: We report our experience with ultrasound augmented reality (US-AR) guidance for mitral valve prosthesis (MVP) implantation in the pig using off-pump, closed, beating intracardiac access through the Guiraudon Universal Cardiac Introducer attached to the left atrial appendage. Methods: Before testing US-AR guidance, a feasibility pilot study on nine pigs was performed using US alone. US-AR guidance, tested on a heart phantom, was subsequently used in three pigs (~65 kg) using a tracked transesophageal echocardiography probe, augmented with registration of a 3D computed tomography scan, and virtual representation of the MVP and clip-delivering tool (Clipper); three pigs were used to test feature-based registration. Results: Navigation of the MVP was facilitated by the 3D anatomic display. AR displayed the MVP and the Clipper within the Atamai Viewer, with excellent accuracy for tool placement. Positioning the Clipper was hampered by the design of the MVP holder and Clipper. These limitations were well displayed by AR, which provided guidance for improved design of tools. Conclusions: US-AR provided informative image guidance. It documented the flaws of the current implantation technology. This information could not be obtained by any other method of evaluation. These evaluations provided guidance for designing an integrated tool: combining an unobtrusive valve holder that allows the MVP to function properly as soon as positioned, and an anchoring system, with clips that can be released one at a time, and retracted if necessary, for optimal results. The portability of Real-time US-AR may prove to be the ideal practical image guidance system for all closed intracardiac interventions.Keywords
This publication has 17 references indexed in Scilit:
- Mitral valve implantation using off-pump closed beating intracardiac surgery: a feasibility studyInteractive CardioVascular and Thoracic Surgery, 2007
- En Bloc Exclusion of the Pulmonary Vein Region in the Pig Using Off Pump, Beating, Intra-Cardiac Surgery: A Pilot Study of Minimally Invasive Surgery for Atrial FibrillationThe Annals of Thoracic Surgery, 2005
- Three-dimensional echocardiography–guided beating-heart surgery without cardiopulmonary bypass: A feasibility studyThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Beating-heart mitral valve surgery: Preliminary model and methodologyThe Journal of Thoracic and Cardiovascular Surgery, 2002
- Closed-chest coronary artery bypass grafting on the beating heart with the use of a computer-enhanced surgical robotic systemThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Surgery Without Interventions?Pacing and Clinical Electrophysiology, 1998
- Surgical treatment of Wolff-Parkinson-White syndrome: A “retrospectroscopic” viewThe Annals of Thoracic Surgery, 1994
- Surgery for Wolff-Parkinson-White syndrome: further experience with an epicardial approach.Circulation, 1986
- Demonstration of macroreentry and feasibility of operative therapy in the common type of atrial flutterThe American Journal of Cardiology, 1986
- Surgical correction of the wolff-parkinson-white syndrome in the closed heart using cryosurgery: A simplified approachJACC, 1984