Latest Publications

  • Revisiting heart activation-conduction physiology, part I: atria

    by Gerard M. Guiraudon, Douglas L. Jones

    This discussion paper re-examines the conduction-activation of the atria, based on observations, with respect to the complexity of the heart as an organ with a brain, and its evolution from a peristaltic tube. The atria do not require a specialized conduction system because they use the subendocardial layer to produce centripetal transmural activation fronts, regardless of the anatomical and histological organization of the transmural atrial wall. This has been described as “two-layer” physiology which provides robust transmission of activation from the sinus to the AV node via a centripetal transmural activation front. New productive insights can come from re-examining the physiology, not only during sinus rhythm but also during atrial tachycardias, in particular atrial flutter and atrial fibrillation (AF). During common flutter, the areas of slow conduction, in the isthmus and following trabeculations, particularly the subendocardial layer confines conduction through the trabeculations which supports re-entry. During experimental or postoperative flutter, the circular 2D activation around the obstacle follows the physiological transmural activation. Understanding this physiology offers insights into AF. During acute or protracted AF, the presence of stationary or drifting rotors is characteristic and consistent with normal physiological 2D atrial activation, suggesting that suppressing physiological transmural activation of AF will permanently restore normal sinus node atrial activation. In contrast, during permanent AF, normal 2D activation is abolished; the presence of transmural, serpentine, and chaotic atrial activation suggests that the normal physiological activation pattern has been replaced by a new, irreversible variety of atrial conduction that is a new physiology, which is consistent with evolution of complex systems.


  • Revisiting right atrial isolation rationale for atrial fibrillation: functional anatomy of interatrial connections

    by Gerard M. Guiraudon, Douglas L. Jones, Allan Skanes, Edward Tweedie, George J. Klein

    Introduction Direct catheter ablation for atrial fibrillation does not yield reproducible permanent control as for other atrial arrhythmias. Therefore, there is a need for an alternative intervention, i.e., left atrial exclusion, based on elective ablation of the interatrial connecting bundles. Methods and results We describe the “operative anatomy” of the three major interatrial connections: the Bachmann bundle, the coronary sinus bundle, and the left atrial-atrioventricular node connection, based on macroscopic dissections of human and porcine hearts and our previous experience. We identified the three right atrial attachments, with the coronary sinus (CS) and left atrial (LA)–atrioventricular (AV) nodal connection being most problematic for safe ablation. Conclusions To obtain a complete isolation of the left from the right atrium, all three connections must be ablated. The CS connection must be ablated distal to the ostium. If present, the LA–AV nodal connection can be safely ablated from the left atrium.


  • Hybrid Access to Atria via the Guiraudon Universal Cardiac Introducer for Arrhythmia Ablation after Total Cavopulmonary Derivation

    by Gérard M. Guiraudon, Douglas L. Jones, Daniel Bainbridge, Laurence Cohen, Yves Lecompte, Françoise Hidden-Lucet, Robert Frank, Alain Pavie

    We report the first use of a new platform, the Guiraudon Universal Cardiac Introducer (GUCI), in humans for accessing the left atrium for catheter-based ablations in patients with resistant atrial arrhythmias after total cavopulmonary derivation. The GUCI was originally designed for intracardiac access for closed, beating instrumental intracardiac surgery. The patient was a 29-year-old man with problematic atrial arrhythmias resistant to antiarrhythmic drugs because of severe uncontrolled bradycardia and because his pacemaker was explanted for infection. The GUCI was attached to the left atrial appendage via an anterior left thoracotomy. The GUCI was modified to accommodate introduction and manipulation of multiple catheters. This allowed electrophysiologists to perform catheter-based exploration and ablation. A DDD pacemaker was implanted, with an atrial endocardial lead introduced via the GUCI cuff and a ventricular epicardial lead. Postoperative atrial arrhythmias were controlled using amiodarone and atrial pacing. At the 12-month follow-up, the patient was arrhythmia- and drug-free and returned to full employment. This new access offers an additional new alternative atrial access to treat resistant arrhythmia after total cavopulmonary derivation. The current state-of-the-art makes patient selection difficult and uncomfortable for the surgeons because of incomplete preoperative electrophysiological data, such as a return to the beginning of surgery for arrhythmia; however, more cumulative experience with intraoperative electrophysiological data and new mapping technologies should address these limitations.


  • Open Access

    Hybrid Access to Atria via the Guiraudon Universal Cardiac Introducer for Arrhythmia Ablation after Total Cavopulmonary Derivation

    by Gérard M. Guiraudon, Douglas L. Jones, Daniel Bainbridge, Laurence Cohen, Yves Lecompte, Françoise Hidden-Lucet, Robert Frank, Alain Pavie

    We report the first use of a new platform, the Guiraudon Universal Cardiac Introducer (GUCI), in humans for accessing the left atrium for catheter-based ablations in patients with resistant atrial arrhythmias after total cavopulmonary derivation. The GUCI was originally designed for intracardiac access for closed, beating instrumental intracardiac surgery. The patient was a 29-year-old man with problematic atrial arrhythmias resistant to antiarrhythmic drugs because of severe uncontrolled bradycardia and because his pacemaker was explanted for infection. The GUCI was attached to the left atrial appendage via an anterior left thoracotomy. The GUCI was modified to accommodate introduction and manipulation of multiple catheters. This allowed electrophysiologists to perform catheter-based exploration and ablation. A DDD pacemaker was implanted, with an atrial endocardial lead introduced via the GUCI cuff and a ventricular epicardial lead. Postoperative atrial arrhythmias were controlled using amiodarone and atrial pacing. At the 12-month follow-up, the patient was arrhythmia- and drug-free and returned to full employment. This new access offers an additional new alternative atrial access to treat resistant arrhythmia after total cavopulmonary derivation. The current state-of-the-art makes patient selection difficult and uncomfortable for the surgeons because of incomplete preoperative electrophysiological data, such as a return to the beginning of surgery for arrhythmia; however, more cumulative experience with intraoperative electrophysiological data and new mapping technologies should address these limitations.

  • Open Access

    Augmented Reality Image Guidance during Off-Pump Mitral Valve Replacement through the Guiraudon Universal Cardiac Introducer

    by Gerard M. Guiraudon, Douglas L. Jones, Daniel Bainbridge, Cristian Linte, Danielle Pace, John Moore, Christopher Wedlake, Pencilla Lang, Terry M. Peters

    Objective: We report our experience with ultrasound augmented reality (US-AR) guidance for mitral valve prosthesis (MVP) implantation in the pig using off-pump, closed, beating intracardiac access through the Guiraudon Universal Cardiac Introducer attached to the left atrial appendage. Methods: Before testing US-AR guidance, a feasibility pilot study on nine pigs was performed using US alone. US-AR guidance, tested on a heart phantom, was subsequently used in three pigs (~65 kg) using a tracked transesophageal echocardiography probe, augmented with registration of a 3D computed tomography scan, and virtual representation of the MVP and clip-delivering tool (Clipper); three pigs were used to test feature-based registration. Results: Navigation of the MVP was facilitated by the 3D anatomic display. AR displayed the MVP and the Clipper within the Atamai Viewer, with excellent accuracy for tool placement. Positioning the Clipper was hampered by the design of the MVP holder and Clipper. These limitations were well displayed by AR, which provided guidance for improved design of tools. Conclusions: US-AR provided informative image guidance. It documented the flaws of the current implantation technology. This information could not be obtained by any other method of evaluation. These evaluations provided guidance for designing an integrated tool: combining an unobtrusive valve holder that allows the MVP to function properly as soon as positioned, and an anchoring system, with clips that can be released one at a time, and retracted if necessary, for optimal results. The portability of Real-time US-AR may prove to be the ideal practical image guidance system for all closed intracardiac interventions.


  • Open Access

    Off-Pump Positioning of a Conventional Aortic Valve Prosthesis through the Left Ventricular Apex with the Universal Cardiac Introducer under Sole Ultrasound Guidance, in the Pig

    by Gerard M. Guiraudon, Douglas L. Jones, Daniel Bainbridge, Terence M. Peters

    To test an alternative to catheter and open-heart techniques, by documenting the feasibility of implanting an unmodified mechanical aortic valve (AoV) in the off pump, beating heart using the universal cardiac introducer (UCI) attached to the left ventricular (LV) apex. In six pigs, the LV apex was exposed by a median sternotomy. The UCI was attached to the apex. A 12-mm punching tool (punch), introduced through the UCI, was used to create a cylindrical opening through the apex. Then, the AoV, secured to a holder, was introduced into the LV, using transesophageal echocardiographic, guided through the apical LV opening, navigated into the LV outflow tract, and positioned within the aortic annulus. Trans-esophageal echocardiographic guidance was useful for navigation and positioning by superimposing the aortic annulus and prosthetic ring while Doppler imaging verified preserved prosthetic function and absence of perivalvular leaks. The valve function and hemodynamics were observed before termination for macroscopic evaluation. The punch produced a clean opening without fragmentation or myocardial embolization. During advancement of the mechanical AoV, there were no arrhythmias, mitral valve dysfunctions, evidence of myocardial ischemia, or hemodynamic instability. The AoVs were well seated over the annulus, without obstructing the coronaries or contact with the conduction system. The ring of AoVs was well circumscribed by the aortic annulus. This study documented the feasibility of positioning a mechanical AoV on the closed, beating heart. These results should encourage the development of adjunct technologies to deliver current tissue or mechanical AoV with minimal side effects.

  • Open Access

    Off-Pump Atrial Septal Defect Closure Using the Universal Cardiac Introducer®

    by Gerard M. Guiraudon, Douglas L. Jones, Daniel Bainbridge, John T. Moore, Chris Wedlake, Cristian Linte, Andrew Wiles, Terry M. Peters

    Optimal atrial septal defect (ASD) closure should combine off-pump techniques with the effectiveness and versatility of open-heart techniques. We report our experience with off-pump ASD closure using the Universal Cardiac Introducer (UCI) in a porcine model. The goal was to create an ASD over the fossa ovale (FO) and position a patch over the ASD under ultrasound (US) imaging and augmented virtual reality guidance. An US probe (tracked with a magnetic tracking system) was positioned into the esophagus (transesophageal echocardiographic probe) for real-time image-guidance. The right atrium (RA) of six pigs was exposed via a right lateral thoracotomy or medial sternotomy. The UCI was attached to the RA wall. A punching tool was introduced via the UCI, navigated and positioned, under US guidance, to create an ASD into the FO. A patch with its holder and a stapling device were introduced into the RA via the UCI. The patch was positioned on the ASD. Occlusion of the ASD was determined using US and Doppler imaging. The FO membrane was excised successfully in all animals. US image-guidance provided excellent visualization. The patch was positioned in all cases with complete occlusion of the ASD. The stapling device proved too bulky, impeding circumferential positioning. Using the UCI, ASD closure was safe and feasible. US imaging, combined with virtual and augmented reality provided accurate navigating and positioning. This study also provided valuable information on the future design of anchoring devices for intracardiac procedures.


  • Anatomical pitfalls during encircling cryoablation of the left atrium for atrial fibrillation therapy in the pig

    by Douglas L. Jones, Gerard M. Guiraudon, Allan C. Skanes, Colette M. Guiraudon

    We previously published encircling endocardial cryo-isolation of the pulmonary vein (PV) region. This study documented mechanisms of isolation failure using CARTO® mapping. Cryo-isolation used a modified Surgifrost® introduced via a Universal Cardiac Introducer® on the left atrial appendage. Of five pigs, two had incomplete isolation and repeat mapping: Activation was over Bachmann’s bundle (BB) in one and the coronary sinus (CS) in the other. Repeat cryoablation failed to eliminate gaps. Histologically, the BB gap had nonlesioned sub-epicardial fibres and thick fat covering the cryolesioned BB: fat protecting the epicardium from cryoablation. The inferior gap had a large CS, and a thick myocardium bridging the isthmus: myocardial thickness and CS thermal sink preventing transmural cryolesions. CARTO® mapping localized gaps. Although the CS is known to cause failure, its protective mechanism is not well documented. The BB gap is novel. These findings have important clinical implications for isolation of the PV region.


  • Open Access

    Mitral valve implantation using off-pump closed beating intracardiac surgery: a feasibility study

    by Gerard M. Guiraudon, Douglas L. Jones, Daniel Bainbridge, Terry M. Peters

    We have developed the Universal Cardiac Introducer® (UCI) with the aim of modernizing the off-pump, closed, beating, intracardiac approach. This pape


  • En Bloc Exclusion of the Pulmonary Vein Region in the Pig Using Off Pump, Beating, Intra-Cardiac Surgery: A Pilot Study of Minimally Invasive Surgery for Atrial Fibrillation

    by Gerard M. Guiraudon, Douglas L. Jones, Allan C. Skanes, Daniel Bainbridge, Colette M. Guiraudon, Steen M. Jensen, Xiaping Yuan, Maria Drangova, Terry M. Peters