Demagnetization Monitoring and Identification in PM Generators With Concentrated Windings During Transient Conditions
- 14 November 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 1510-1518
Abstract
Direct drive permanent magnet machines used in renewables typically have high numbers of poles leading to low speeds. This poses a challenge for detection of faults during transients, while few periods of the operating waveforms can be captured. Moreover, it has been recently shown that the numbers of poles and stator coils determine the demagnetization harmonic generation mechanism and consequently the location of the fault signatures. This leads to different signatures in every permanent magnet machine. Additionally, the traditional signatures may not be clear in the spectrograms due to the low rotor speed. Under such conditions, the monitoring of specific higher harmonics can lead to reliable detection and identification of the demagnetization fault. The authors prove that the fault can be reliably distinguished from other rotor-related faulty conditions with the use of specific higher signatures in the stator current. Finally, the computed harmonics are experimentally verified in the lab, while the detection of demagnetization under transient conditions is achieved in this paper, that studies a double rotor axial flux PM generator as a case subject.Keywords
This publication has 31 references indexed in Scilit:
- Comprehensive review on inter‐turn fault indexes in permanent magnet motorsIET Electric Power Applications, 2017
- Comprehensive Analysis of Magnet Defect Fault Monitoring Through Leakage FluxIEEE Transactions on Magnetics, 2016
- On the Accuracy of Fault Detection and Separation in Permanent Magnet Synchronous Machines Using MCSA/MVSA and LDAIEEE Transactions on Energy Conversion, 2016
- Computationally Efficient Method for Identifying Manufacturing Induced Rotor and Stator Misalignment in Permanent Magnet Brushless MachinesIEEE Transactions on Industry Applications, 2016
- Trends in Wind Turbine Generator SystemsIEEE Journal of Emerging and Selected Topics in Power Electronics, 2013
- Circulating current in parallel connected stator windings due to rotor eccentricity in permanent magnet motors2013
- Nonstationary Motor Fault Detection Using Recent Quadratic Time–Frequency RepresentationsIEEE Transactions on Industry Applications, 2008
- Detecting Rotor Faults in Low Power Permanent Magnet Synchronous MachinesIEEE Transactions on Power Electronics, 2007
- Detection of stator short circuits in VSI-fed brushless DC motors using wavelet transformIEEE Transactions on Energy Conversion, 2006
- Grain growth effects on the corrosion behavior of nanocrystalline NdFeB magnetsCorrosion Science, 2002