Giorgos A. Skarmoutsos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Giorgos A. Skarmoutsos has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Konstantinos N. Gyftakis
School of Electrical and Computer Engineering, Technical University of Crete, 731 00 Chania, Greece
7 shared publications - Markus Mueller
Institute for Energy Systems, School of Engineering, The University of Edinburgh, Edinburgh, U.K.
7 shared publications - Daniel Morinigo-Sotelo
Research Group HSPdigital-ADIRE, Institute of Advanced Production Technologies (ITAP), University of Valladolid, 47011 Valladolid, Spain
2 shared publications - Rene de Jesus Romero-Troncoso
HSPdigital—C.A. Mecatronica, Autonomous University of Queretaro, San Juan del Rio 76806, Mexico
2 shared publications - Tomas Alberto Garcia-Calva
Department of Electrical Engineering, University of Valladolid, 47002 Valladolid, Spain
2 shared publications A. C. Barmpatza
University of Patras,Department of Electrical and Computer EngineeringPatraGreece,26504
1 shared publication
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8205915
The Exact 2-D Composite-Subdomain Analytical Solution for Magnetic Field Computation in Surface-Mounted Permanent-Magnet Machines Accounting Finitely Permeable Teeth
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8205915
The Exact 2-D Composite-Subdomain Analytical Solution for Magnetic Field Computation in Surface-Mounted Permanent-Magnet Machines Accounting Finitely Permeable Teeth
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-11
General Diagnostics in Direct-Drive Permanent-Magnet Synchronous Generators Using Two Magnetically-Coupled Search-Coils
This paper aims to present a novel magnetic flux condition monitoring method based on two search coils. The proposed method can detect all the common faults occurring in Permanent-Magnet machines. The idea is based on two search coils, one placed in the rotor and one in the stator, which couple magnetically under faulty conditions due to their relative motion. The induced voltage distribution on the stationary search-coil is associated with the type of fault, and the amplitude with the fault severity. The studied faults are the local demagnetization, inter-turn, static and dynamic eccentricity. The induced voltage on the stator search-coil was derived under inter-turn fault and partial demagnetization to provide more insight into the mechanism of the proposed method. 2-Dimensional Finite-Element Analysis simulation and experimental results by two radial-flux permanent-magnet machines with different power output classes support that the method can be used effectively for condition monitoring of all the faults under stationary and non-stationary speeds and loads.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-11
General Diagnostics in Direct-Drive Permanent-Magnet Synchronous Generators Using Two Magnetically-Coupled Search-Coils
This paper aims to present a novel magnetic flux condition monitoring method based on two search coils. The proposed method can detect all the common faults occurring in Permanent-Magnet machines. The idea is based on two search coils, one placed in the rotor and one in the stator, which couple magnetically under faulty conditions due to their relative motion. The induced voltage distribution on the stationary search-coil is associated with the type of fault, and the amplitude with the fault severity. The studied faults are the local demagnetization, inter-turn, static and dynamic eccentricity. The induced voltage on the stator search-coil was derived under inter-turn fault and partial demagnetization to provide more insight into the mechanism of the proposed method. 2-Dimensional Finite-Element Analysis simulation and experimental results by two radial-flux permanent-magnet machines with different power output classes support that the method can be used effectively for condition monitoring of all the faults under stationary and non-stationary speeds and loads.
- 6 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Advanced Signal Processing Techniques for Demagnetization Detection in PM Generators at Variable Speed
In this paper, demagnetization detection in permanent magnet generators is analyzed using advanced signal processing techniques. The t-f decomposition of the current signal is calculated using the min-norm method. Three signal processing techniques are investigated which are the adaptive demodulation, the time-varying resampling and the envelope analysis. The merits of these methods are thoroughly compared against the commonly adopted short-time Fourier transform analysis. Moreover, traditional signal processing techniques may not be suitable for fault detection when the machine operates at variable speed. Under such condition, interference between the fundamental frequency of the machine and the fault harmonic can lead to false alarms. Simulation test and experimental results demonstrate effective performance and feasibility of the proposed methods for demagnetization detection of permanent generators operating under non-stationary conditions.
- 6 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Advanced Signal Processing Techniques for Demagnetization Detection in PM Generators at Variable Speed
In this paper, demagnetization detection in permanent magnet generators is analyzed using advanced signal processing techniques. The t-f decomposition of the current signal is calculated using the min-norm method. Three signal processing techniques are investigated which are the adaptive demodulation, the time-varying resampling and the envelope analysis. The merits of these methods are thoroughly compared against the commonly adopted short-time Fourier transform analysis. Moreover, traditional signal processing techniques may not be suitable for fault detection when the machine operates at variable speed. Under such condition, interference between the fundamental frequency of the machine and the fault harmonic can lead to false alarms. Simulation test and experimental results demonstrate effective performance and feasibility of the proposed methods for demagnetization detection of permanent generators operating under non-stationary conditions.
- 31 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 6655-6663
Critical Aspects of Demagnetization Faults in Multi-Stage Direct Drive Permanent Magnet Generators for Renewables
Demagnetization of permanent magnet machines is a fault that evolves over time leading to an eventual catastrophic failure. This condition is of particular interest in renewables, with emphasis on remote applications such as offshore wind, tidal and wave energy harvesting. Moreover, the demagnetization fault can be either uniform or non-uniform. The strong majority of research papers are focusing on non-uniform demagnetization and typically study the case of a single faulty magnet. This is because, the uniform demagnetization does not create harmonics that can be detected with spectral methods. Despite the above, the study of single magnet demagnetization studies have been criticized due to being unrealistic to describe most practical cases where permanent magnet machines are subjected to demagnetization due to overloading and/or overheating conditions and leading to uniform demagnetization. This paper sheds some light into such theories, while studying a, realistically induced in the lab, demagnetization case of a direct-drive C-GEN permanent magnet generator. The goals of this research are to examine the generated harmonic index due to the fault, the distribution of the demagnetization in space and the impact of the fault on the multiple generator stages due to the circulating currents.
- 31 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 6655-6663
Critical Aspects of Demagnetization Faults in Multi-Stage Direct Drive Permanent Magnet Generators for Renewables
Demagnetization of permanent magnet machines is a fault that evolves over time leading to an eventual catastrophic failure. This condition is of particular interest in renewables, with emphasis on remote applications such as offshore wind, tidal and wave energy harvesting. Moreover, the demagnetization fault can be either uniform or non-uniform. The strong majority of research papers are focusing on non-uniform demagnetization and typically study the case of a single faulty magnet. This is because, the uniform demagnetization does not create harmonics that can be detected with spectral methods. Despite the above, the study of single magnet demagnetization studies have been criticized due to being unrealistic to describe most practical cases where permanent magnet machines are subjected to demagnetization due to overloading and/or overheating conditions and leading to uniform demagnetization. This paper sheds some light into such theories, while studying a, realistically induced in the lab, demagnetization case of a direct-drive C-GEN permanent magnet generator. The goals of this research are to examine the generated harmonic index due to the fault, the distribution of the demagnetization in space and the impact of the fault on the multiple generator stages due to the circulating currents.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 1510-1518
Demagnetization Monitoring and Identification in PM Generators With Concentrated Windings During Transient Conditions
Direct drive permanent magnet machines used in renewables typically have high numbers of poles leading to low speeds. This poses a challenge for detection of faults during transients, while few periods of the operating waveforms can be captured. Moreover, it has been recently shown that the numbers of poles and stator coils determine the demagnetization harmonic generation mechanism and consequently the location of the fault signatures. This leads to different signatures in every permanent magnet machine. Additionally, the traditional signatures may not be clear in the spectrograms due to the low rotor speed. Under such conditions, the monitoring of specific higher harmonics can lead to reliable detection and identification of the demagnetization fault. The authors prove that the fault can be reliably distinguished from other rotor-related faulty conditions with the use of specific higher signatures in the stator current. Finally, the computed harmonics are experimentally verified in the lab, while the detection of demagnetization under transient conditions is achieved in this paper, that studies a double rotor axial flux PM generator as a case subject.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 1510-1518
Demagnetization Monitoring and Identification in PM Generators With Concentrated Windings During Transient Conditions
Direct drive permanent magnet machines used in renewables typically have high numbers of poles leading to low speeds. This poses a challenge for detection of faults during transients, while few periods of the operating waveforms can be captured. Moreover, it has been recently shown that the numbers of poles and stator coils determine the demagnetization harmonic generation mechanism and consequently the location of the fault signatures. This leads to different signatures in every permanent magnet machine. Additionally, the traditional signatures may not be clear in the spectrograms due to the low rotor speed. Under such conditions, the monitoring of specific higher harmonics can lead to reliable detection and identification of the demagnetization fault. The authors prove that the fault can be reliably distinguished from other rotor-related faulty conditions with the use of specific higher signatures in the stator current. Finally, the computed harmonics are experimentally verified in the lab, while the detection of demagnetization under transient conditions is achieved in this paper, that studies a double rotor axial flux PM generator as a case subject.
- 29 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (2) , 1011-1019
Analytical Prediction of the MCSA Signatures Under Dynamic Eccentricity in PM Machines With Concentrated Non-Overlapping Windings
This paper proposes a novel algorithm which made it feasible to predict the harmonic fault signatures under dynamic eccentricity in Permanent-Magnet synchronous machines with concentrated non-overlapping winding for any slot-pole combination. In the literature, only the appearance of the fractional harmonic components related with the pole number has been proposed but there are no studies to predict which exact components will rise in each topology. Initially, a mathematical equation is derived for the machine EMF under dynamic eccentricity based on the air gap permeance model. Later on, the terms of this equation are inserted in a Fault Signature Block Binary Array in which the position of each cell expresses a specific harmonic frequency component. After substitution of the machines parameters, the array results with zero and nonzero terms. The positions of the nonzero terms express the frequency components excited by this particular fault. 3-D FEA and experimental results of a Permanent-Magnet Axial-Flux Machine are used to validate the proposed algorithm.
- 29 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (2) , 1011-1019
Analytical Prediction of the MCSA Signatures Under Dynamic Eccentricity in PM Machines With Concentrated Non-Overlapping Windings
This paper proposes a novel algorithm which made it feasible to predict the harmonic fault signatures under dynamic eccentricity in Permanent-Magnet synchronous machines with concentrated non-overlapping winding for any slot-pole combination. In the literature, only the appearance of the fractional harmonic components related with the pole number has been proposed but there are no studies to predict which exact components will rise in each topology. Initially, a mathematical equation is derived for the machine EMF under dynamic eccentricity based on the air gap permeance model. Later on, the terms of this equation are inserted in a Fault Signature Block Binary Array in which the position of each cell expresses a specific harmonic frequency component. After substitution of the machines parameters, the array results with zero and nonzero terms. The positions of the nonzero terms express the frequency components excited by this particular fault. 3-D FEA and experimental results of a Permanent-Magnet Axial-Flux Machine are used to validate the proposed algorithm.
- Open Access
- 7 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2934-2944
The Demagnetization Harmonics Generation Mechanism in Permanent Magnet Machines With Concentrated Windings
Partial demagnetization is a condition that may occur in Permanent Magnet machines due to overloading or thermal stress. When this happens, the magnetic field locally weakens leading to an asymmetry of the air-gap field. This asymmetry will cause harmonics, which will be expressed as extra losses and mechanical oscillations. Moreover, since the field becomes weaker, more current is required to serve the load leading to less efficiency, increased losses and consequently increase of the temperature, which will cause further progression of the demagnetization severity until a total machine breakdown. Several methods have been proposed in the literature for the online detection of the demagnetization, however they have not related the fault to the manufacturing characteristics of the machine, which play an important role on the expected harmonic index and the associated fault signatures. This paper presents for the first time a detailed analytical investigation of the expected harmonics in the stator current spectrum in case of demagnetization, as a function of the stator winding and number of poles. The analytical results are verified by extensive simulations via the finite element method and experimental testing.
- 7 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2934-2944
Open AccessThe Demagnetization Harmonics Generation Mechanism in Permanent Magnet Machines With Concentrated Windings
Partial demagnetization is a condition that may occur in Permanent Magnet machines due to overloading or thermal stress. When this happens, the magnetic field locally weakens leading to an asymmetry of the air-gap field. This asymmetry will cause harmonics, which will be expressed as extra losses and mechanical oscillations. Moreover, since the field becomes weaker, more current is required to serve the load leading to less efficiency, increased losses and consequently increase of the temperature, which will cause further progression of the demagnetization severity until a total machine breakdown. Several methods have been proposed in the literature for the online detection of the demagnetization, however they have not related the fault to the manufacturing characteristics of the machine, which play an important role on the expected harmonic index and the associated fault signatures. This paper presents for the first time a detailed analytical investigation of the expected harmonics in the stator current spectrum in case of demagnetization, as a function of the stator winding and number of poles. The analytical results are verified by extensive simulations via the finite element method and experimental testing.
- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (5) , 3295-3305
Detecting Partial Demagnetization in AFPM Generators by Monitoring Speed and EMF Induced in a Supplemental Winding
In this article, a novel method to detect the partial demagnetization in air-cored permanent-magnet axial-flux generators is proposed. Its principle is to monitor a speed-normalized fault detection signal. This signal depends only on the demagnetization severity, as it was extracted using a flux-sensor with a span that negates the induced voltage under balanced conditions. The generator has been designed for marine renewable applications working under variable speed conditions rending PM health monitoring under nonstationary conditions imperative. Initially, a mathematical equation for the electromotive force is derived under partial demagnetization conditions with the aim to extract the frequency components related to the fault. To estimate the demagnetization severity, an approach was developed based on the magnetic flux monitoring, which penetrates throughout the sensor. A 3-D finiteelement model of the installed winding in the generator is employed to verify the proposed method under steady and variable speed conditions.
- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (5) , 3295-3305
Detecting Partial Demagnetization in AFPM Generators by Monitoring Speed and EMF Induced in a Supplemental Winding
In this article, a novel method to detect the partial demagnetization in air-cored permanent-magnet axial-flux generators is proposed. Its principle is to monitor a speed-normalized fault detection signal. This signal depends only on the demagnetization severity, as it was extracted using a flux-sensor with a span that negates the induced voltage under balanced conditions. The generator has been designed for marine renewable applications working under variable speed conditions rending PM health monitoring under nonstationary conditions imperative. Initially, a mathematical equation for the electromotive force is derived under partial demagnetization conditions with the aim to extract the frequency components related to the fault. To estimate the demagnetization severity, an approach was developed based on the magnetic flux monitoring, which penetrates throughout the sensor. A 3-D finiteelement model of the installed winding in the generator is employed to verify the proposed method under steady and variable speed conditions.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 163-168
Investigation of Static Angular and Axis Misalignment in an AFPM Generator
This study investigates the effect of the static angular and the static axis misalignment on an axial flux permanent magnet (AFPM) machine using 3D finite element method (FEM). The AFPM machine is a single-stator-single-rotor generator with a coreless, star-connected stator. The EMF waveforms of the machine coils, the corresponding spectra, as well as the spectra of the phase EMF sum (V S ) are used for the identification of the faults. The main novelty is that the EMF coil waveforms and spectra have not been used previously for diagnostic purposes in the static axis misalignment. In addition, there are not papers in the international literature that use the voltage V S spectrum for eccentricity diagnosis in AFPM machines.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 163-168
Investigation of Static Angular and Axis Misalignment in an AFPM Generator
This study investigates the effect of the static angular and the static axis misalignment on an axial flux permanent magnet (AFPM) machine using 3D finite element method (FEM). The AFPM machine is a single-stator-single-rotor generator with a coreless, star-connected stator. The EMF waveforms of the machine coils, the corresponding spectra, as well as the spectra of the phase EMF sum (V S ) are used for the identification of the faults. The main novelty is that the EMF coil waveforms and spectra have not been used previously for diagnostic purposes in the static axis misalignment. In addition, there are not papers in the international literature that use the voltage V S spectrum for eccentricity diagnosis in AFPM machines.