Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
Open Access
- 22 November 2017
- Vol. 10 (11) , 1340
Abstract
Shear connectors are used in steel beam–concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1% higher than that of the shear connectors with D13.Keywords
All Related Versions
This publication has 32 references indexed in Scilit:
- Ultimate strength of a steel–concrete composite bridge deck slab with profiled sheetingEngineering Structures, 2010
- Experimental assessment of Perfobond and T-Perfobond shear connectors’ structural responseJournal of Constructional Steel Research, 2009
- Structural behaviour of T-Perfobond shear connectors in composite girders: An experimental approachEngineering Structures, 2008
- Experimental analysis of Perfobond shear connection between steel and lightweight concreteJournal of Constructional Steel Research, 2004
- Behaviour of composite substructures with full and partial shear connection under quasi-static cyclic and pseudo-dynamic displacementsMaterials and Structures, 2000
- Numerical analysis of push-out specimens with perfobond rib connectorsComputers & Structures, 1997
- Push-out tests on studs in high strength and normal strength concreteJournal of Constructional Steel Research, 1996
- A parametric study of perfobond rib shear connectorsCanadian Journal of Civil Engineering, 1994
- Behaviour of perfobond rib shear connectors in composite beams: full-size testsCanadian Journal of Civil Engineering, 1992
- Neues, vorteilhaftes Verbundmittel für Stahlverbund‐Tragwerke mit hoher Dauerfestigkeit.Beton- und Stahlbetonbau, 1987