Kun-Soo Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kun-Soo Kim has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Sang-Hyo Kim
4 shared publicationsOneil Han
2 shared publicationsRobin Eunju Kim
2 shared publications- Se-Jun Park
Flash Product Technology, Samsung Electronics Co.,Pyeongtaek,Korea,17786
2 shared publications - Tabish Ali
Department of Civil & Environmental Engineering, Hanyang University, Seoul 04763, Republic of Korea
2 shared publications - Byung-Keun Oh
Department of Chemical and Biomolecular Engineering, Sogang University, 35, Baekbeom-ro, Mapo-gu, Seoul 04107, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 October 2023
- Published by Elsevier in Developments in the Built Environment
- Vol. 16
Nonlinear finite element modeling and parametric analysis for the design implication of expanded rib steel bars in RC beams
- 1 October 2023
- Published by Elsevier in Developments in the Built Environment
- Vol. 16
Open AccessNonlinear finite element modeling and parametric analysis for the design implication of expanded rib steel bars in RC beams
- Open Access
- 8 September 2023
- Published by Elsevier in Engineering Structures
- Vol. 295
Development of a novel connection method using expanded rib and spiral bars for reinforced concrete beams with cold joints
- 8 September 2023
- Published by Elsevier in Engineering Structures
- Vol. 295
Open AccessDevelopment of a novel connection method using expanded rib and spiral bars for reinforced concrete beams with cold joints
- 1 March 2019
- Published by Elsevier in Construction and Building Materials
- Vol. 200, 64-79
Hysteretic performance of stubby Y-type perfobond rib shear connectors depending on transverse rebar
- 1 March 2019
- Published by Elsevier in Construction and Building Materials
- Vol. 200, 64-79
Hysteretic performance of stubby Y-type perfobond rib shear connectors depending on transverse rebar
- 1 August 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 180, 254-264
Influence of transverse rebar on shear behavior of Y-type perfobond rib shear connection
- 1 August 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 180, 254-264
Influence of transverse rebar on shear behavior of Y-type perfobond rib shear connection
- Open Access
Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
Shear connectors are used in steel beam–concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1% higher than that of the shear connectors with D13.
Open AccessAnalysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
Shear connectors are used in steel beam–concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1% higher than that of the shear connectors with D13.
- 1 September 2017
- Published by Elsevier in Engineering Structures
- Vol. 147, 114-124
Comparison of hysteretic performance of stubby Y-type perfobond rib and stud shear connectors
- 1 September 2017
- Published by Elsevier in Engineering Structures
- Vol. 147, 114-124
Comparison of hysteretic performance of stubby Y-type perfobond rib and stud shear connectors
- 1 July 2016
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 122, 445-454
Y-type perfobond rib shear connectors subjected to fatigue loading on highway bridges
- 1 July 2016
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 122, 445-454
Y-type perfobond rib shear connectors subjected to fatigue loading on highway bridges
- Open Access
- 1 July 2016
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 291 (27) , 14213-14230
Iron- and Quorum-sensing Signals Converge on Small Quorum-regulatory RNAs for Coordinated Regulation of Virulence Factors in Vibrio vulnificus
- 1 July 2016
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 291 (27) , 14213-14230
Open AccessIron- and Quorum-sensing Signals Converge on Small Quorum-regulatory RNAs for Coordinated Regulation of Virulence Factors in Vibrio vulnificus
- 1 February 2008
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 313-314, 439-443
Electrochemical characterization of molecular orientation effect on self-assembled recombinant ferredoxin
- 1 February 2008
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 313-314, 439-443
Electrochemical characterization of molecular orientation effect on self-assembled recombinant ferredoxin