Stereoscopic X-ray image and thermo-optical surface guidance for breast cancer radiotherapy in deep inspiration breath-hold
Authors:
Open Access
- 5 October 2023
- journal article
- research article
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 200 (4) , 306-313
Abstract
Purpose: To investigate the feasibility of a thermo-optical surface imaging (SGRT) system combined with room-based stereoscopic X‑ray image guidance (IGRT) in a dedicated breast deep inspiration breath-hold (DIBH) irradiation workflow. In this context, benchmarking of portal imaging (EPID) and cone-beam CT (CBCT) against stereoscopic X‑rays was performed. Methods: SGRT + IGRT data of 30 left-sided DIBH breast patients (1 patient with bilateral cancer) treated in 351 fractions using thermo-optical surface imaging and X-ray IGRT were retrospectively analysed. Patients were prepositioned based on a free-breathing surface reference derived from a CT scan. Once the DIBH was reached using visual feedback, two stereoscopic X‑ray images were acquired and registered to the digitally reconstructed radiographs derived from the DIBH CT. Based on this registration, a couch correction was performed. Positioning and monitoring by surface and X-ray imaging were verified by protocol-based EPID or CBCT imaging at selected fractions and the calculation of residual geometric deviations. Results: The median X‑ray-derived couch correction vector was 4.9 (interquartile range [IQR] 3.3–7.1) mm long. Verification imaging was performed for 134 fractions (216 RT field verifications) with EPID and for 37 fractions with CBCT, respectively. The median 2D/3D deviation vector length over all verification images was 2.5 (IQR 1.6–3.9) mm/3.4 (IQR 2.2–4.8) mm for EPID/CBCT, both being well within the planning target volume (PTV) margins (7 mm). A moderate correlation (0.49–0.65) was observed between the surface signal and X-ray position in DIBH. Conclusion: DIBH treatments using thermo-optical SGRT and X-ray IGRT were feasible for breast cancer patients. Stereoscopic X‑ray positioning was successfully verified by standard IGRT techniques.Keywords
Funding Information
- Medical University of Vienna
This publication has 27 references indexed in Scilit:
- Dosimetric effects of intrafractional isocenter variation during deep inspiration breath‐hold for breast cancer patients using surface‐guided radiotherapyJournal of Applied Clinical Medical Physics, 2017
- Left-sided breast cancer and risks of secondary lung cancer and ischemic heart diseaseStrahlentherapie und Onkologie, 2017
- Cardiac dose reduction with deep inspiration breath hold for left-sided breast cancer radiotherapy patients with and without regional nodal irradiationRadiation Oncology, 2015
- Risk of Ischemic Heart Disease in Women after Radiotherapy for Breast CancerNew England Journal of Medicine, 2013
- Radiation-related mortality from heart disease and lung cancer more than 20 years after radiotherapy for breast cancerBritish Journal of Cancer, 2012
- Study of ExacTrac X‐ray 6D IGRT setup uncertainty for marker‐based prostate IMRT treatmentJournal of Applied Clinical Medical Physics, 2012
- IGRT induced dose burden for a variety of imaging protocols at two different anatomical sitesRadiotherapy and Oncology, 2012
- Clinical Results of Image-Guided Deep Inspiration Breath Hold Breast IrradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Use of the BrainLAB ExacTrac X-Ray 6D System in Image-Guided RadiotherapyMedical Dosimetry, 2008
- Deep inspiration breath hold to reduce irradiated heart volume in breast cancer patientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001