Effect of simulated masticatory loading on the retention of stud attachments for implant overdentures
- 6 September 2010
- journal article
- research article
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 38 (3) , 157-164
Abstract
This study assessed the effect of simulated mastication on the retention of two stud attachment systems for 2-implants overdentures. Sixteen specimens, each simulating an edentulous ridge with implants and an overdenture were divided into two groups, according to the attachment system: Group I (Nobel Biocare ball-socket attachments) and Group II (Locator attachments). Retention forces were measured before and after 400,000 simulated masticatory loads in a customised device. Data were compared by two-way anova followed by Bonferroni test (α = 0·05). Group I presented significantly lower retention forces (Newtons) than Group II at baseline (10·6 ± 3·6 and 66·4 ± 16·0, respectively). However, differences were not significant after 400,000 loads (7·9 ± 4·3 and 21·6 ± 17·0). The number of cycles did not influence the measurements in Group I, whereas a non-linear descending curve was found for Group II. It was concluded that simulated mastication resulted in minor changes for the ball attachment tested. Nevertheless, it reduced the retention of Locator attachments to 40% of the baseline values, what suggests that mastication is a major factor associated with maintenance needs for this system.Keywords
This publication has 24 references indexed in Scilit:
- The Change in Retentive Values of Locator Attachments and Hader Clips over TimeJournal of Prosthodontics, 2009
- Mandibular overdentures supported by two or four endosseous implants: a 10‐year clinical trialClinical Oral Implants Research, 2009
- Implant overdentures for edentulous elders: study of patient preferenceGerodontology, 2009
- Is there a certain number of implants needed to retain an overdenture?Journal of Oral Rehabilitation, 2007
- An Eight-year Follow-up to a Randomized Clinical Trial of Aftercare and Cost-analysis with Three Types of Mandibular Implant-retained OverdenturesJournal of Dental Research, 2007
- Retention Characteristics of Attachment Systems for Implant OverdenturesJournal of Prosthodontics, 2004
- The McGill Consensus Statement on Overdentures Mandibular two‐implant overdentures as first choice standard of care for edentulous patientsGerodontology, 2002
- Effectiveness of three treatment modalities for the edentulous mandibleClinical Oral Implants Research, 2000
- Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: An in vitro studyThe Journal of Prosthetic Dentistry, 1998
- Comparative study of two precision overdenture attachment designsThe Journal of Prosthetic Dentistry, 1996