Gas Chromatography/Femtosecond Multiphoton Ionization/Time-of-Flight Mass Spectrometry of Dioxins
- 1 July 2010
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (15) , 6519-6525
Abstract
Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry (GC/MPI/TOF-MS) was developed for trace analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). The use of an ultraviolet femtosecond laser (266 nm) allowed the sensitive, as well as selective, determination of PCDD/Fs with short singlet-excited-state lifetimes; the detection limit was 19 fg for 1,3,6,8-tetraCDF. Performance of the analytical instrument was examined and was ascertained to be satisfactory for all the criteria (K0311) prescribed by the Japanese Industrial Standards (JIS). The relative ionization efficiencies of (12)C-native PCDD/Fs against (13)C-labeled PCDD/Fs were 1.002 +/- 0.012. This suggests that (13)C-labeled isotopes can be used as internal standards with no intensity calibration and that the concentrations of PCDD/Fs can be determined to within an error of ca. 1%. In addition, multiphoton ionization provides negligible levels of background interference for the real soil samples even with curtailed pretreatment. The toxicity equivalence (TEQ) of the real sample was determined using GC/MPI/TOF-MS for performance evaluation against high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). The results suggest equivalent or even superior performance for GC/MPI/TOF-MS, due to low background interference and to the ability to check the reliability of the assignment from the intensity distribution of the isotope peaks.Keywords
This publication has 23 references indexed in Scilit:
- The 2005 World Health Organization Reevaluation of Human and Mammalian Toxic Equivalency Factors for Dioxins and Dioxin-Like CompoundsToxicological Sciences, 2006
- Development of a Compact Supersonic Jet/Multiphoton Ionization/Time-of-Flight Mass Spectrometer for the On-site Analysis of Dioxin, Part I: Evaluation of Basic PerformanceAnalytical Sciences, 2003
- Development of a Compact Supersonic Jet/Multiphoton Ionization/Time-of-Flight Mass Spectrometer for the On-site Analysis of Dioxin, Part II: Application to Chlorobenzene and DibenzofuranAnalytical Sciences, 2003
- Identification of surrogate compounds for the emission of PCDD/F (I-TEQ value) and evaluation of their on-line real-time detectability in flue gases of waste incineration plants by REMPI–TOFMS mass spectrometryChemosphere, 2001
- On-Line Emission Analysis of Polycyclic Aromatic Hydrocarbons down to pptv Concentration Levels in the Flue Gas of an Incineration Pilot Plant with a Mobile Resonance-Enhanced Multiphoton Ionization Time-of-Flight Mass SpectrometerAnalytical Chemistry, 1998
- Continuous monitoring of ultratrace products of incomplete combustion during incineration with a novel mobile Jet-REMPI deviceChemosphere, 1998
- A Mobile Resonance-enhanced Multiphoton Ionization Time-of-flight Mass Spectrometry Device for On-line Analysis of Aromatic Pollutants in Waste Incinerator Flue Gases: First ResultsRapid Communications in Mass Spectrometry, 1997
- Laser ion sources for time-of-flight mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1994
- Optically selective molecular mass spectrometryAnalytical Chemistry, 1987
- Analysis of polyaromatic hydrocarbon mixtures with laser ionization gas chromatography/mass spectrometryAnalytical Chemistry, 1983