YWYuka Watanabe-Ezoe

Yuka Watanabe-Ezoe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuka Watanabe-Ezoe has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Tomohiro Uchimura

    Department of Materials Science and Engineering, Graduate School of Engineering, University of Fukui, Fukui, Japan

    6 shared publications
  • Totaro Imasaka

    Faculty of Design, Kyushu University, 4-9-1, Shiobaru, Minami-ku, Fukuoka 815-8540: 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan

    4 shared publications
  • Totaro Imasaka

    Department of Applied Chemistry, Graduate School of Engineering, Kyushu University

    3 shared publications
  • Kiyomi Ito

    Department of Clinical Pharmacokinetics, Hoshi University, 2-4-41 Ebara, Shinagawa-ku, Tokyo 142-8501, Japan

    2 shared publications
  • Kiyoshi Sugiyama

    Department of Functional Molecule Kinetics School of Pharmacy and Pharmaceutical Sciences, Hoshi University Tokyo Japan

    2 shared publications
  • Nami Nakamura

    Department of Applied Chemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi, Fukuoka 819-0395, Japan

    2 shared publications

Latest Publications

  • Differences in Opinions on Nuclear Power Generation between Japanese and Korean University Students

    by Yuka Watanabe, Kazuhiko Kudo, Kazuya Idemitsu

    After the Fukushima Daiichi nuclear power plant accident, public opinion of nuclear power generation changed. In this study, the differences in opinions of nuclear power generation between Japanese and Korean university students were examined. The surveys were conducted at three universities using paper questionnaires. It was found that students studying nuclear engineering in both countries had more favorable opinions of nuclear power than those studying other majors. In comparison, trust in the government’s management of nuclear power plants and the perceived danger of nuclear power plants also affected opinions of nuclear power plants in both countries. These results cannot be generalized because the number of respondents was limited.

  • Open Access

    Inhibitory Effects of Daiokanzoto (Da-Huang-Gan-Cao-Tang) on P-Glycoprotein

    by Yuka Watanabe, Nobutomo Ikarashi, Toshiyuki Satoh, Kiyomi Ito, Wataru Ochiai, Kiyoshi Sugiyama

    We have studied the effects of various Kampo medicines on P-glycoprotein (P-gp), a drug transporter,in vitro. The present study focused on Daiokanzoto (Da-Huang-Gan-Cao-Tang), which shows the most potent inhibitory effects on P-gp among the 50 Kampo medicines studied, and investigated the P-gp inhibitory effects of Daiokanzoto herbal ingredients (rhubarb and licorice root) and their components by an ATPase assay using human P-gp membrane. Both rhubarb and licorice root significantly inhibited ATPase activity, and the effects of rhubarb were more potent than those of licorice root. The content of rhubarb in Daiokanzoto is double that in licorice root, and the inhibition patterns of Daiokanzoto and rhubarb involve both competitive and noncompetitive inhibition, suggesting that the inhibitory effects of Daiokanzoto are mainly due to rhubarb. Concerning the components of rhubarb, concentration-dependent inhibitory effects were observed for (−)-catechin gallate, (−)-epicatechin gallate, and (−)-epigallocatechin gallate. In conclusion, rhubarb may cause changes in the drug dispositions of P-gp substrates through the inhibition of P-gp. It appears that attention should be given to the interactions between these drugs and Kampo medicines containing rhubarb as an herbal ingredient.


  • Open Access

    Polychlorinated Aromatic Hydrocarbons in a Soil Sample Measured Using Gas Chromatography/Multiphoton Ionization/Time-of-Flight Mass Spectrometry

    by Nami Nakamura, Tomohiro Uchimura, Yuka Watanabe-Ezoe, Totaro Imasaka

    Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry (GC/MPI/TOF-MS) was applied to a soil sample to survey several groups of polychlorinated aromatic hydrocarbons (polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs), polychlorinated diphenylethers (PCDEs), and polychlorinated terphenyls (PCTs)). The signal peaks in the two-dimensional display of GC/MS could be easily and accurately assigned from the intensity distribution of the isotope peaks, even in the presence of numerous interfering species. Using this technology, mutual interferences between organochlorine compounds can be readily recognized from the data of the two-dimensional display after a measurement, although the separation of these compounds is sometimes difficult using high-resolution magnetic-sector-type mass spectrometry. This approach, based on MPI, results in less fragmentation, and is useful for the identification of analytes. Thus, GC/MPI/TOF-MS allows for the simultaneous determination of PCDD/Fs and related compounds in real samples containing numerous interfering species.


  • Analysis of Dioxins by Gas Chromatography/Resonance-Enhanced Multiphoton Ionization/Mass Spectrometry Using Nanosecond and Picosecond Lasers

    by Adan Li, Tomohiro Uchimura, Yuka Watanabe-Ezoe, Totaro Imasaka

    Dioxins in a soil sample were measured using gas chromatography/resonance-enhanced multiphoton ionization/time-of-flight mass spectrometry coupled with different types of laser sources. The fourth-harmonic emission (266 nm) of a nanosecond Nd:YAG laser (1 ns) provided low ionization efficiency, especially for highly chlorinated dioxins/dibenzofurans (CDDs/CDFs). The ionization efficiency was improved using the fourth-harmonic emission (266 nm) of a picosecond Nd:YAG laser (4 ps), due to shorter singlet excited-state lifetimes. It was, however, difficult to efficiently ionize hepta-CDD and octa-CDD/CDF, because of their shorter lifetimes, which were induced by stronger spin−orbit coupling that led to efficient relaxation of the excited molecule to triplet levels. The ionization efficiency was substantially improved using the fifth-harmonic emission (213 nm) of the picosecond Nd:YAG laser (4 ps), in which the analyte molecule that was relaxed to triplet levels was efficiently ionized using a photon with sufficient energy for ionization, although the pulse energy obtained at 213 nm was only one-third of the pulse energy obtained at 266 nm. The limits of detection achieved for 17 toxic polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) were 0.41−45 pg. The analytical instrument developed in the present study performed sufficiently well for the practical trace analysis of dioxins in soil samples.


  • Gas Chromatography/Femtosecond Multiphoton Ionization/Time-of-Flight Mass Spectrometry of Dioxins

    by Yuka Watanabe-Ezoe, Xing Li, Tomohiro Uchimura, Totaro Imasaka

    Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry (GC/MPI/TOF-MS) was developed for trace analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). The use of an ultraviolet femtosecond laser (266 nm) allowed the sensitive, as well as selective, determination of PCDD/Fs with short singlet-excited-state lifetimes; the detection limit was 19 fg for 1,3,6,8-tetraCDF. Performance of the analytical instrument was examined and was ascertained to be satisfactory for all the criteria (K0311) prescribed by the Japanese Industrial Standards (JIS). The relative ionization efficiencies of (12)C-native PCDD/Fs against (13)C-labeled PCDD/Fs were 1.002 +/- 0.012. This suggests that (13)C-labeled isotopes can be used as internal standards with no intensity calibration and that the concentrations of PCDD/Fs can be determined to within an error of ca. 1%. In addition, multiphoton ionization provides negligible levels of background interference for the real soil samples even with curtailed pretreatment. The toxicity equivalence (TEQ) of the real sample was determined using GC/MPI/TOF-MS for performance evaluation against high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). The results suggest equivalent or even superior performance for GC/MPI/TOF-MS, due to low background interference and to the ability to check the reliability of the assignment from the intensity distribution of the isotope peaks.


  • Enhancement of Molecular Ions in Mass Spectrometry Using an Ultrashort Optical Pulse in Multiphoton Ionization

    by Takashi Shimizu, Yuka Watanabe-Ezoe, Satoshi Yamaguchi, Hiroko Tsukatani, Tomoko Imasaka, Shin-Ichi Zaitsu, Tomohiro Uchimura, Totaro Imasaka

    The spectral domain of an ultraviolet femtosecond laser was expanded by stimulated Raman scattering/four-wave Raman mixing, and the resulting laser pulse was compressed using a pair of gratings. The pulse width was then measured using an autocorrelator comprised of a Michelson interferometer equipped with a multiphoton ionization/mass spectrometer which was used as a two-photon detector. A gas chromatograph/mass spectrometer was employed to analyze triacetone triperoxide (TATP), and the molecular ion induced by multiphoton ionization was substantially enhanced by decreasing the laser pulse width.


  • Data processing technique in gas chromatography/time-of-flight mass spectrometry

    by Nami Nakamura, Yuji Sakoda, Satoshi Yamaguchi, Yuka Watanabe-Ezoe, Tomohiro Uchimura, Totaro Imasaka

    A complete mass spectrum was measured at an acquisition rate of 1 kHz using a femtosecond-multiphoton-ionization time-of-flight mass spectrometer for analyte eluting from a gas chromatograph. A contour-map display, i.e. a two-dimensional plot, of the data was first constructed for a simultaneous overview of the mass spectra and the mass chromatograms. The noise component in the signal was then reduced by digital filtering and reduced further by smoothing the data. The detection limit (S/N = 3) was improved from 240 to 76 fg for 2,3,4,6,7-pentachlorodibenzofuran, with no appreciable loss of resolution in the chromatogram. The achieved value was lower than the value (<100 fg) required by Japanese Industrial Standards for dioxin analysis. A new parameter, referred to as a ‘reliability factor’, was defined in this study to calculate the similarity between the intensity distribution of the isotope peaks observed in the mass spectrum and that calculated from the natural abundance ratio of the isotopes. This parameter was useful for evaluation of the purity of the chromatographic peak.


  • Near-ultraviolet femtosecond laser ionization of dioxins in gas chromatography/time-of-flight mass spectrometry

    by Satoshi Yamaguchi, Fumiaki Kira, Yuki Miyoshi, Tomohiro Uchimura, Yuka Watanabe-Ezoe, Shin-Ichi Zaitsu, Totaro Imasaka