The utility of high-frequency jet ventilation in pulsed field ablation for atrial fibrillation
Authors:
- 12 May 2026
- journal article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 69 (8) , 2451-2457
Abstract
Using high-frequency jet ventilation (HFJV) to improve catheter stability with conventional energy sources during atrial fibrillation (AF) ablation is associated with higher ablation success and improved arrhythmic outcomes. The utility of HFJV with pulsed field ablation (PFA) for AF is unclear. We investigated the utility of HFJV vs. standard ventilation in PFA for AF. We studied consecutive cases of patients with AF undergoing PFA between 5/6/24 to 10/10/24. Procedural data collected included total procedure time and major periprocedural complications. Clinical data collected included atrial tachyarrhythmia (ATA) recurrence, stroke, and major bleeding at one-year follow-up. Outcomes were compared in cases where HFJV was used vs. standard ventilation. A total of 512 patients were included in this study (307 standard ventilation, 205 HFJV). There was no difference in ATA recurrence by Kaplan-Meier survival analysis between standard ventilation and HFJV groups (log rank test p = 0.59). When comparing standard ventilation vs. HFJV groups, there was no difference in ATA recurrence at one year (23% vs. 26%; p = 0.43), AF burden on continuous monitoring (9 ± 5% vs. 8 ± 24%; p = 0.85), total procedure time (114 ± 38 vs. 115 ± 33 min; p = 0.78), or major periprocedural complications (3% vs. 2%; p = 0.64). There was no difference in arrhythmic outcomes when patients were stratified by AF type and whether patients presented for first-time or redo ablation. Using HFJV in PFA for AF produces similar sinus rhythm maintenance overall and when stratified by AF type without affecting procedure times or complication rate.Keywords
This publication has 12 references indexed in Scilit:
- Ensuring catheter-tissue contact with intracardiac echocardiography during pulsed-field ablation improves procedure outcome in patients with atrial fibrillationHeart Rhythm, 2025
- In vivo assessment of catheter-tissue contact using tissue proximity indication and its impact on cardiac lesion formation in pulsed field ablationHeart Rhythm, 2024
- Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial FibrillationNew England Journal of Medicine, 2023
- High-Frequency Low-Tidal Volume Ventilation Improves Long-Term Outcomes in AF AblationJACC: Clinical Electrophysiology, 2023
- Rapid pacing and high‐frequency jet ventilation additively improve catheter stability during atrial fibrillation ablationJournal of Cardiovascular Electrophysiology, 2020
- Initiation of a High-Frequency Jet Ventilation Strategy for Catheter Ablation for Atrial FibrillationJACC: Clinical Electrophysiology, 2018
- Evaluation of a Strategy Aiming to Enclose the Pulmonary Veins With Contiguous and Optimized Radiofrequency Lesions in Paroxysmal Atrial FibrillationJACC: Clinical Electrophysiology, 2018
- High frequency jet ventilation for motion management during ablation procedures, a narrative reviewActa Anaesthesiologica Scandinavica, 2017
- Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmiasHeart Rhythm, 2012
- Definition of major bleeding in clinical investigations of antihemostatic medicinal products in non‐surgical patientsJournal of Thrombosis and Haemostasis, 2005