Corrected position estimation in PET detector modules with multi-anode PMTs using neural networks
- 26 June 2006
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (3) , 776-783
Abstract
This paper studies the use of Neural Networks (NNs) for estimating the position of impinging photons in gamma ray detector modules for PET cameras based on continuous scintillators and Multi-Anode Photomultiplier Tubes (MA-PMTs). The detector under study is composed of a 49/spl times/49/spl times/10 mm/sup 3/ continuous slab of LSO coupled to a flat panel H8500 MA-PMT. Four digitized signals from a charge division circuit, which collects currents from the 8/spl times/8 anode matrix of the photomultiplier, are used as inputs to the NN, thus reducing drastically the number of electronic channels required. We have simulated the computation of the position for 511 keV gamma photons impacting perpendicularly to the detector surface. Thus, we have performed a thorough analysis of the NN architecture and training procedures in order to achieve the best results in terms of spatial resolution and bias correction. Results obtained using GEANT4 simulation toolkit show a resolution of 1.3 mm/1.9 mm FWHM at the center/edge of the detector and less than 1 mm of systematic error in the position near the edges of the scintillator. The results confirm that NNs can partially model and correct the non-uniform detector response using only the position-weighted signals from a simple 2D DPC circuit. Linearity degradation for oblique incidence is also investigated. Finally, the NN can be implemented in hardware for parallel real time corrected Line-of-Response (LOR) estimation. Results on resources occupancy and throughput in FPGA are presented.Keywords
This publication has 8 references indexed in Scilit:
- Depth of /spl gamma/-ray interaction within continuous crystals from the width of its scintillation light-distributionIEEE Transactions on Nuclear Science, 2005
- Neural network-based position estimators for PET detectors using monolithic LSO blocksIEEE Transactions on Nuclear Science, 2004
- Evaluation of Maximum-Likelihood Position Estimation With Poisson and Gaussian Noise Models in a Small Gamma CameraIEEE Transactions on Nuclear Science, 2004
- Optimal nonlinear line-of-flight estimation in positron emission tomographyIEEE Transactions on Nuclear Science, 2003
- Investigation of bias-free positioning estimators for the scintillation camerasIEEE Transactions on Nuclear Science, 2001
- Simple charge division readouts for imaging scintillator arrays using a multi-channel PMTIEEE Transactions on Nuclear Science, 1996
- Improving the learning speed of 2-layer neural networks by choosing initial values of the adaptive weights1990
- Scintillation CameraReview of Scientific Instruments, 1958