An Onboard Executable Multitask Network Model for Bioradar-Based ECG Signal Reconstruction Using High-Fidelity DHD Signals
- 6 October 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-20
Abstract
Bioradar-based Electrocardiogram (ECG) reconstruction shows great promise in replacing traditional contact-based ECG collection methods for non-contact, long-term healthcare applications, such as continuous cardiorespiratory disease monitoring and early warning systems. In this work, we first designed a practical bioradar system for high Signal-to-Noise Ratio (SNR) I/Q baseband signal acquisition, achieving excellent performance with background noise not exceeding 3.18 μVpp and SNRs ranging from 26 to 119 dB. Next, we developed a high-linearity arctangent demodulation method to extract high-fidelity Doppler Heartbeat Diagram (DHD) signals. Finally, we introduced a lightweight UNet-based multitask network model for ECG signal reconstruction, which demonstrated performance achieving Root Mean Squared Error (RMSE) values of 0.160 and 0.330, Root Mean Absolute Error (RMAE) values of 0.261 and 0.400, and Pearson Correlation Coefficient (PCC) values of 95.17% and 85.26% for two different datasets, respectively. This model is characterized by low computational complexity, with 7.04M parameters, Floating-Point Operations (FLOPs) of 889.16 M, real-time processing speed of 1.05 s per execution, and low power consumption of 379.5mW. Moreover, it requires just 29.13MB of Random Access Memory (RAM) and 10.49MB of Read-Only Memory (ROM), making it highly suitable for deployment in embedded systems. Experimental results from both a public dataset and our own dataset show that the proposed lightweight ECG reconstruction model, when combined with the designed high-fidelity DHD signal acquisition bioradar system, holds significant potential for non-contact healthcare and medical applications.Keywords
Funding Information
- National Natural Science Foundation of China (62402041, 62272044, 62227807)
- National Key Research and Development Program of China (2023YFC2506804, 2022YFC3500503)
- STI2030-Major Projects (2021ZD0200408, 2021ZD0201900)
- Beijing Natural Science Foundation (L243034)
- Japan Society for the Promotion of Science (S24116)
- Teli Young Fellow Program from Beijing Institute of Technology, China.
This publication has 59 references indexed in Scilit:
- Monitoring long-term cardiac activity with contactless radio frequency signalsNature Communications, 2024
- Accurate ECG-Free Heartbeats Localization in Long-Lasting SCG Recordings2024
- EarSteth: Cardiac Auscultation Audio Reconstruction Using EarbudsAnnual International Conference of the IEEE Engineering in Medicine and Biology Society, 2024
- ECG waveform generation from radar signals: A deep learning perspectiveComputers in Biology and Medicine, 2024
- Radar-Beat: Contactless beat-by-beat heart rate monitoring for life scenesBiomedical Signal Processing and Control, 2023
- Photonic radar for contactless vital sign detectionNature Photonics, 2023
- Artificial intelligence-enhanced electrocardiography in cardiovascular disease managementNature Reviews Cardiology, 2021
- A dataset of clinically recorded radar vital signs with synchronised reference sensor signalsScientific Data, 2020
- Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensorNature Electronics, 2019
- The non-contact measure of the heart rate variability by laser Doppler vibrometry: comparison with electrocardiographyMeasurement Science and Technology, 2016