Jie Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Liu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Bin Hu
Beijing Institute of Technology
2 shared publications - Björn Schuller
Technische Universität München, Munich, Germany
2 shared publications - Fuze Tian
School of Information Science and Engineering, Lanzhou University, Lanzhou, China
2 shared publications - Haojie Zhang
School of Medical Technology, Beijing Institute of Technology, Beijing, China
2 shared publications - Jingyu Liu
School of Medical Technology, Beijing Institute of Technology, Beijing, China
2 shared publications - Kun Qian
Beijing Institute of Technology
2 shared publications
Latest Publications
- 6 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-20
An Onboard Executable Multitask Network Model for Bioradar-Based ECG Signal Reconstruction Using High-Fidelity DHD Signals
Bioradar-based Electrocardiogram (ECG) reconstruction shows great promise in replacing traditional contact-based ECG collection methods for non-contact, long-term healthcare applications, such as continuous cardiorespiratory disease monitoring and early warning systems. In this work, we first designed a practical bioradar system for high Signal-to-Noise Ratio (SNR) I/Q baseband signal acquisition, achieving excellent performance with background noise not exceeding 3.18 μVpp and SNRs ranging from 26 to 119 dB. Next, we developed a high-linearity arctangent demodulation method to extract high-fidelity Doppler Heartbeat Diagram (DHD) signals. Finally, we introduced a lightweight UNet-based multitask network model for ECG signal reconstruction, which demonstrated performance achieving Root Mean Squared Error (RMSE) values of 0.160 and 0.330, Root Mean Absolute Error (RMAE) values of 0.261 and 0.400, and Pearson Correlation Coefficient (PCC) values of 95.17% and 85.26% for two different datasets, respectively. This model is characterized by low computational complexity, with 7.04M parameters, Floating-Point Operations (FLOPs) of 889.16 M, real-time processing speed of 1.05 s per execution, and low power consumption of 379.5mW. Moreover, it requires just 29.13MB of Random Access Memory (RAM) and 10.49MB of Read-Only Memory (ROM), making it highly suitable for deployment in embedded systems. Experimental results from both a public dataset and our own dataset show that the proposed lightweight ECG reconstruction model, when combined with the designed high-fidelity DHD signal acquisition bioradar system, holds significant potential for non-contact healthcare and medical applications.
- 6 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-20
An Onboard Executable Multitask Network Model for Bioradar-Based ECG Signal Reconstruction Using High-Fidelity DHD Signals
Bioradar-based Electrocardiogram (ECG) reconstruction shows great promise in replacing traditional contact-based ECG collection methods for non-contact, long-term healthcare applications, such as continuous cardiorespiratory disease monitoring and early warning systems. In this work, we first designed a practical bioradar system for high Signal-to-Noise Ratio (SNR) I/Q baseband signal acquisition, achieving excellent performance with background noise not exceeding 3.18 μVpp and SNRs ranging from 26 to 119 dB. Next, we developed a high-linearity arctangent demodulation method to extract high-fidelity Doppler Heartbeat Diagram (DHD) signals. Finally, we introduced a lightweight UNet-based multitask network model for ECG signal reconstruction, which demonstrated performance achieving Root Mean Squared Error (RMSE) values of 0.160 and 0.330, Root Mean Absolute Error (RMAE) values of 0.261 and 0.400, and Pearson Correlation Coefficient (PCC) values of 95.17% and 85.26% for two different datasets, respectively. This model is characterized by low computational complexity, with 7.04M parameters, Floating-Point Operations (FLOPs) of 889.16 M, real-time processing speed of 1.05 s per execution, and low power consumption of 379.5mW. Moreover, it requires just 29.13MB of Random Access Memory (RAM) and 10.49MB of Read-Only Memory (ROM), making it highly suitable for deployment in embedded systems. Experimental results from both a public dataset and our own dataset show that the proposed lightweight ECG reconstruction model, when combined with the designed high-fidelity DHD signal acquisition bioradar system, holds significant potential for non-contact healthcare and medical applications.
- Open Access
- 30 July 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (7) , 33419
Atrial Fibrillation Termination Success During Ablation: Insights From Pooled Clinical Studies
Background: The optimal endpoint for ablation in persistent atrial fibrillation (pers-AF) remains unclear. This study aimed to systematically evaluate the prognostic value of acute AF termination in predicting the recurrence of arrhythmias. Methods: A systematic search of the PubMed, Cochrane Library, Web of Science, and Embase databases was conducted from inception to July 2023. Only studies with reports of acute termination for pers-AF and its predictive role in arrhythmia recurrence were included. Subgroup analysis was performed to identify potential confounders for the effect of AF termination. Results: A total of 22 studies were included in the meta-analysis. The pooled analysis indicated that acute termination of AF is significantly associated with an increased long-term success rate (relative risk (RR), 1.53; 95% CI, 1.41–1.66; p < 0.001; I2 = 35.4%). Moreover, subgroup analysis revealed that patients with an AF duration >12 months (RR, 1.92; 95% CI, 1.57–2.35; p < 0.001), aged >60 years (RR, 1.92; 95% CI, 1.60–2.31; p < 0.001) may derive benefits from AF termination during ablation. Interestingly, a significant interaction was observed in the study design subgroup, where multi-center studies showed a success rate of RR, 1.31 (95% CI, 1.14–1.50; p < 0.001), while single-center studies exhibited a higher success rate of RR, 1.65 (95% CI, 1.49–1.82; p < 0.001), with an interaction p-value of 0.008. Importantly, acute termination of AF did not significantly increase procedural complications (RR, 1.19; 95% CI, 0.59–2.39; p = 0.627; I2 = 0.0%). Conclusions: Our study suggests that AF acute termination during ablation for pers-AF provides a better long-term clinical outcome. The PROSPERO Registration: CRD42023431015, https://www.crd.york.ac.uk/PROSPERO/view/CRD42023431015.
- 30 July 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (7) , 33419
Open AccessAtrial Fibrillation Termination Success During Ablation: Insights From Pooled Clinical Studies
Background: The optimal endpoint for ablation in persistent atrial fibrillation (pers-AF) remains unclear. This study aimed to systematically evaluate the prognostic value of acute AF termination in predicting the recurrence of arrhythmias. Methods: A systematic search of the PubMed, Cochrane Library, Web of Science, and Embase databases was conducted from inception to July 2023. Only studies with reports of acute termination for pers-AF and its predictive role in arrhythmia recurrence were included. Subgroup analysis was performed to identify potential confounders for the effect of AF termination. Results: A total of 22 studies were included in the meta-analysis. The pooled analysis indicated that acute termination of AF is significantly associated with an increased long-term success rate (relative risk (RR), 1.53; 95% CI, 1.41–1.66; p < 0.001; I2 = 35.4%). Moreover, subgroup analysis revealed that patients with an AF duration >12 months (RR, 1.92; 95% CI, 1.57–2.35; p < 0.001), aged >60 years (RR, 1.92; 95% CI, 1.60–2.31; p < 0.001) may derive benefits from AF termination during ablation. Interestingly, a significant interaction was observed in the study design subgroup, where multi-center studies showed a success rate of RR, 1.31 (95% CI, 1.14–1.50; p < 0.001), while single-center studies exhibited a higher success rate of RR, 1.65 (95% CI, 1.49–1.82; p < 0.001), with an interaction p-value of 0.008. Importantly, acute termination of AF did not significantly increase procedural complications (RR, 1.19; 95% CI, 0.59–2.39; p = 0.627; I2 = 0.0%). Conclusions: Our study suggests that AF acute termination during ablation for pers-AF provides a better long-term clinical outcome. The PROSPERO Registration: CRD42023431015, https://www.crd.york.ac.uk/PROSPERO/view/CRD42023431015.
- Top Cited Papers
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 24 (8) , 7252-7266
An AI-Assisted All-in-One Integrated Coronary Artery Disease Diagnosis System Using a Portable Heart Sound Sensor With an On-Board Executable Lightweight Model
Heart sounds play a crucial role in assessing Coronary Artery Disease (CAD). The advancement of Artificial Intelligence (AI) technologies has given rise to Computer Audition (CA)-based methods for CAD detection. However, previous research has focused primarily on analyzing and modeling heart sound data, overlooking practical application scenarios. In this work, we design a pervasive heart sound collection device used for high-quality heart sound data acquisition. Moreover, we introduce an on-board executable lightweight network tailored for the designed portable device, referred to as TYKDModel. Further, heart sound data from 41 CAD patients and 22 non-CAD healthy controls are collected using the developed device. Experimental results show that the TYKDModel exhibits low-computational complexity, with 52.16 K parameters and 5.03 M Floating-Point Operations (FLOPs). When deployed on the board, it requires only 1.10 MB of Random Access Memory (RAM) and 236.27 KB of Read-Only Memory (ROM), and takes around 1.72 seconds to perform a classification. Despite the low computational and spatial complexity, the TYKDModel achieves a notable classification accuracy of 85.2%, specificity of 88.6%, and sensitivity of 82.8% on the board. These results indicate the promising potential of AI-assisted all-in-one integrated system for the diagnosis of heart sound-assisted CAD.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 24 (8) , 7252-7266
Top Cited PapersAn AI-Assisted All-in-One Integrated Coronary Artery Disease Diagnosis System Using a Portable Heart Sound Sensor With an On-Board Executable Lightweight Model
Heart sounds play a crucial role in assessing Coronary Artery Disease (CAD). The advancement of Artificial Intelligence (AI) technologies has given rise to Computer Audition (CA)-based methods for CAD detection. However, previous research has focused primarily on analyzing and modeling heart sound data, overlooking practical application scenarios. In this work, we design a pervasive heart sound collection device used for high-quality heart sound data acquisition. Moreover, we introduce an on-board executable lightweight network tailored for the designed portable device, referred to as TYKDModel. Further, heart sound data from 41 CAD patients and 22 non-CAD healthy controls are collected using the developed device. Experimental results show that the TYKDModel exhibits low-computational complexity, with 52.16 K parameters and 5.03 M Floating-Point Operations (FLOPs). When deployed on the board, it requires only 1.10 MB of Random Access Memory (RAM) and 236.27 KB of Read-Only Memory (ROM), and takes around 1.72 seconds to perform a classification. Despite the low computational and spatial complexity, the TYKDModel achieves a notable classification accuracy of 85.2%, specificity of 88.6%, and sensitivity of 82.8% on the board. These results indicate the promising potential of AI-assisted all-in-one integrated system for the diagnosis of heart sound-assisted CAD.