Clinical Assessment of Potential Difference in Motion-Tracking Irradiation for Liver Tumors Using Radixact Synchrony®
Authors:
Open Access
- 2 April 2025
- journal article
- Published by Springer Nature in Cureus
- Vol. 17 (4) , e81598
Abstract
This study aimed to advance the precision of motion-managed radiotherapy and provide robust information for clinical practice in terms of necessary margins using Radixact Synchrony® (Accuray, Sunnyvale, USA). A retrospective analysis was conducted on 88 irradiation sessions in nine cases of motion-tracking irradiation for liver tumors. Two gold markers were placed near the tumor, and a planning target volume (PTV) margin of 5 mm was set. The interruption threshold for potential difference (PD) (the statistical prediction value of the three-dimensional (3D) distance error from the predictive model) was set at 3.0 mm during treatment. PD values obtained before and during treatment, as well as the number of interruptions, were analyzed. A multiple regression analysis was performed to evaluate the influence of various planning parameters, which were obtained during four-dimensional (4D) treatment planning, on the 95th percentile value of PD (PD95). The mean PD95 was 2.9 ± 0.6 mm. In the four cases where interruptions occurred, the average ± SD number of interruptions per fraction was 7.5 ± 4.6, 3.6 ± 2.5, 2.5 ± 1.5, and 1.0 ± 1.1, respectively. The coefficient of determination (adjusted R2) between PD95 and planning parameters was 0.802 (p < 0.01), showing a positive correlation with respiratory motion amplitude (p = 0.017) and a negative correlation with inter-marker distance (p = 0.049). No treatment interruptions were experienced in 83.0% of a total of 88 fractions. To conclude, setting a PD interruption threshold of 3.0 mm for motion-tracking irradiation using Radixact Synchrony® under metallic marker guidance for liver tumors was appropriate for minimizing treatment interruptions with sufficient dosimetric precision. In addition, inter-marker distance and respiratory motion amplitude were associated with PD95.Keywords
This publication has 14 references indexed in Scilit:
- Optimal threshold of a control parameter for tomotherapy respiratory tracking: A phantom studyJournal of Applied Clinical Medical Physics, 2023
- Technical note: Tracking target/chest relationship changes during motion‐synchronized tomotherapy treatmentsMedical Physics, 2022
- Evaluation of radixact motion synchrony for 3D respiratory motion: Modeling accuracy and dosimetric fidelityJournal of Applied Clinical Medical Physics, 2020
- Technical Note: Comprehensive performance tests of the first clinical real‐time motion tracking and compensation system using MLC and jawsMedical Physics, 2020
- Geometrical tracking accuracy and appropriate PTV margins for robotic radiosurgery of liver lesions by SBRTActa Oncologica, 2019
- Validation of the liver mean dose in terms of the biological effective dose for the prevention of radiation-induced liver damageReports of Practical Oncology and Radiotherapy, 2017
- Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver MetastasesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2017
- Dosimetric impact of Lipiodol in stereotactic body radiation therapy on liver after trans‐arterial chemoembolizationMedical Physics, 2016
- Accuracy of Robotic Radiosurgical Liver Treatment Throughout the Respiratory CycleInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- Hypofractionated three‐dimensional conformal radiation therapy for primary liver carcinomaCancer, 2005