Impact of the Detected Scintillation Light Intensity on Neutron-Gamma Discrimination
Open Access
- 5 September 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (10) , 2197-2203
Abstract
This paper reports the method and the results of a study on the impact of the detected light intensity on gamma-neutron discrimination. In particular, the minimum number of photons required to achieve a statistically significant separation was measured and shown to be stable against a variation of the Photon Detection Efficiency (PDE) of the system under study. The method, developed using an EJ-276 scintillator bar coupled to a Silicon Photomultiplier (SiPM), is of general interest. For this specific system, the minimum statistics was measured to be 317 ± 16 photons, corresponding to different values of the deposited energy, as the PDE was changed.Keywords
This publication has 15 references indexed in Scilit:
- Pulse shape discrimination of CLYC scintillator coupled with a large SiPM arrayNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Investigation into the potential of GAGG:Ce as a neutron detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- EditorialNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Overview on the main parameters and technology of modern Silicon PhotomultipliersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Comparison of the pulse shape discrimination performance of plastic scintillators coupled to a SiPMNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- Tests of a dual-readout fiber calorimeter with SiPM light sensorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Reconstruction of the statistics of photons by a pulsed LED using a Silicon Photomultiplier based set-upJournal of Instrumentation, 2015
- Pulse shape discrimination using EJ-299-33 plastic scintillator coupled with a Silicon Photomultiplier arrayNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Neutron-Gamma Pulse Shape Discrimination Using Organic Scintillators With Silicon Photomultiplier ReadoutIEEE Transactions on Nuclear Science, 2014