Romualdo Santoro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Romualdo Santoro has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Vito Manzari
INFN, Sezione di Bari
84 shared publications - Rosario Turrisi
INFN, Sezione di Padova
82 shared publications - Fernando Scarlassara
Dipartimento di Fisica e Astronomia dell’Università and Sezione INFN
81 shared publications - Tiziano Virgili
Dipartimento di Fisica ‘E.R. Caianiello’ dell’Università and Gruppo Collegato INFN
79 shared publications F. Antinori
Sezione INFN
77 shared publications- Francesco Riggi
Università di Catania e INFN
77 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04040
Impact of front-end parameters of the ARCADIA MD3 on charged particle detection
The ARCADIA INFN R&D project developed a Fully Depleted Monolithic Active Pixel Sensor (FD-MAPS) using a customized LFoundry 110 nm CIS process. The first in-beam characterization of the ARCADIA Main Demonstrator 3 (MD3) sensor with 200 µm active thickness has been performed at the Fermilab Test Beam Facility with a 120 GeV proton beam. The Device Under Test (DUT) is tested with a trigger-less telescope composed of two ARCADIA MD3 tracking planes. This early study investigates the effect of the front-end parameters on the tracking performance.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04040
Open AccessImpact of front-end parameters of the ARCADIA MD3 on charged particle detection
The ARCADIA INFN R&D project developed a Fully Depleted Monolithic Active Pixel Sensor (FD-MAPS) using a customized LFoundry 110 nm CIS process. The first in-beam characterization of the ARCADIA Main Demonstrator 3 (MD3) sensor with 200 µm active thickness has been performed at the Fermilab Test Beam Facility with a 120 GeV proton beam. The Device Under Test (DUT) is tested with a trigger-less telescope composed of two ARCADIA MD3 tracking planes. This early study investigates the effect of the front-end parameters on the tracking performance.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04003
Pixel response characterization of the ARCADIA fully depleted MAPS
Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04003
Open AccessPixel response characterization of the ARCADIA fully depleted MAPS
Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.
- Open Access
- 20 March 2026
- Published by MDPI AG in Electronics
- Vol. 15 (6) , 1300
Ultra-Fast Digital Silicon Photomultiplier with Timestamping Capability in a 110 nm CMOS Process
A monolithic digital Silicon Photomultiplier (SiPM) featuring 1024 microcells with a 30-micrometer pitch and a 50% fill factor has been designed in a 110-nanometer CMOS image sensor technology. The device under consideration integrates both SPAD sensors and front-end electronics in the same substrate. It can count up to 1024 photons in less than 22 ns, while assigning timestamps to the first and last detected photons with a time resolution of less than 100 ps. A parallel counter structure combined with a fast adder tree provides photon counting in digital form with low latency, whereas a carefully balanced fast NAND tree ensures a fixed-pattern time uncertainty not exceeding 26 ps. The architecture incorporates in-pixel memory for individual cell disabling and configurable thresholding on the timing signal for noise mitigation. In order to optimize the fill factor, a part of the electronics is placed outside the array, while the most sensitive elements of the timing and counting circuits are laid out close to the sensor, in the SPAD array. A serial readout is employed to provide a single output connection per SiPM, thereby simplifying system integration.
- 20 March 2026
- Published by MDPI AG in Electronics
- Vol. 15 (6) , 1300
Open AccessUltra-Fast Digital Silicon Photomultiplier with Timestamping Capability in a 110 nm CMOS Process
A monolithic digital Silicon Photomultiplier (SiPM) featuring 1024 microcells with a 30-micrometer pitch and a 50% fill factor has been designed in a 110-nanometer CMOS image sensor technology. The device under consideration integrates both SPAD sensors and front-end electronics in the same substrate. It can count up to 1024 photons in less than 22 ns, while assigning timestamps to the first and last detected photons with a time resolution of less than 100 ps. A parallel counter structure combined with a fast adder tree provides photon counting in digital form with low latency, whereas a carefully balanced fast NAND tree ensures a fixed-pattern time uncertainty not exceeding 26 ps. The architecture incorporates in-pixel memory for individual cell disabling and configurable thresholding on the timing signal for noise mitigation. In order to optimize the fill factor, a part of the electronics is placed outside the array, while the most sensitive elements of the timing and counting circuits are laid out close to the sensor, in the SPAD array. A serial readout is employed to provide a single output connection per SiPM, thereby simplifying system integration.
- 21 March 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 255, 116237
Mass-manufacturable scintillation-based optical fiber dosimeters for brachytherapy
- 21 March 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 255, 116237
Mass-manufacturable scintillation-based optical fiber dosimeters for brachytherapy
- Open Access
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03025
Design and commissioning of a Silicon Photomultiplier-based dosimeter for Low Dose Rate (LDR) oncological brachytherapy
Brachytherapy is a radiotherapy procedure performed with radioactive sources implanted into the patient's body, close to the area affected by cancer. This is a reference procedure for the treatment of prostate and gynecologic cancer due to the reduction of the dose released close to organs at risk (e.g., rectum, bladder, colon). For this reason, real-time dose verification and source localisation are essential for an optimal treatment plan. The ORIGIN collaboration aims to achieve this goal through a 16-fibre sensor system, designed to house a small volume of scintillating material in a transparent fibre tip to enable point-like measurements. The selected scintillating materials feature a decay time of about 500 μs and the signal associated with the primary γ-ray interaction results in the emission of a sequence of single photons distributed over time. Therefore, the dosimeter requires a detector with single-photon sensitivity and a system designed to provide dose measurements by photon counting. Uniformity of fibre response, system stability and reproducibility of measurements are key features of the dosimeter. The characterisation of the 16-channel dosimeter system equipped with thermo-electrically cooled Silicon Photomultipliers, carried out in the laboratory using an X-ray cabinet, is discussed and the results are compared with an earlier version equipped with SiPMs operated at room temperature.
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03025
Open AccessDesign and commissioning of a Silicon Photomultiplier-based dosimeter for Low Dose Rate (LDR) oncological brachytherapy
Brachytherapy is a radiotherapy procedure performed with radioactive sources implanted into the patient's body, close to the area affected by cancer. This is a reference procedure for the treatment of prostate and gynecologic cancer due to the reduction of the dose released close to organs at risk (e.g., rectum, bladder, colon). For this reason, real-time dose verification and source localisation are essential for an optimal treatment plan. The ORIGIN collaboration aims to achieve this goal through a 16-fibre sensor system, designed to house a small volume of scintillating material in a transparent fibre tip to enable point-like measurements. The selected scintillating materials feature a decay time of about 500 μs and the signal associated with the primary γ-ray interaction results in the emission of a sequence of single photons distributed over time. Therefore, the dosimeter requires a detector with single-photon sensitivity and a system designed to provide dose measurements by photon counting. Uniformity of fibre response, system stability and reproducibility of measurements are key features of the dosimeter. The characterisation of the 16-channel dosimeter system equipped with thermo-electrically cooled Silicon Photomultipliers, carried out in the laboratory using an X-ray cabinet, is discussed and the results are compared with an earlier version equipped with SiPMs operated at room temperature.
- Open Access
Characterisation of a Silicon Photomultiplier Based Oncological Brachytherapy Fibre Dosimeter
Source localisation and real-time dose verification are at the forefront of medical research in brachytherapy, an oncological radiotherapy procedure based on radioactive sources implanted in the patient body. The ORIGIN project aims to respond to this medical community’s need by targeting the development of a multi-point dose mapping system based on fibre sensors integrating a small volume of scintillating material into the tip and interfaced with silicon photomultipliers operated in counting mode. In this paper, a novel method for the selection of the optimal silicon photomultipliers to be used is presented, as well as a laboratory characterisation based on dosimetric figures of merit. More specifically, a technique exploiting the optical cross-talk to maintain the detector linearity in high-rate conditions is demonstrated. Lastly, it is shown that the ORIGIN system complies with the TG43-U1 protocol in high and low dose rate pre-clinical trials with actual brachytherapy sources, an essential requirement for assessing the proposed system as a dosimeter and comparing the performance of the system prototype against the ORIGIN project specifications.
Open AccessCharacterisation of a Silicon Photomultiplier Based Oncological Brachytherapy Fibre Dosimeter
Source localisation and real-time dose verification are at the forefront of medical research in brachytherapy, an oncological radiotherapy procedure based on radioactive sources implanted in the patient body. The ORIGIN project aims to respond to this medical community’s need by targeting the development of a multi-point dose mapping system based on fibre sensors integrating a small volume of scintillating material into the tip and interfaced with silicon photomultipliers operated in counting mode. In this paper, a novel method for the selection of the optimal silicon photomultipliers to be used is presented, as well as a laboratory characterisation based on dosimetric figures of merit. More specifically, a technique exploiting the optical cross-talk to maintain the detector linearity in high-rate conditions is demonstrated. Lastly, it is shown that the ORIGIN system complies with the TG43-U1 protocol in high and low dose rate pre-clinical trials with actual brachytherapy sources, an essential requirement for assessing the proposed system as a dosimeter and comparing the performance of the system prototype against the ORIGIN project specifications.
- Open Access
- 22 November 2022
- Published by Sissa Medialab Srl
- Vol. 414, 846
A 16-sensor prototype for brachytherapy in vivo dosimetry characterization
The ORIGIN project (Optical Fiber Dose Imaging for Adaptive Brachytherapy) targets the production and qualification of a real-time radiation dose imaging and source localization system for both Low Dose Rate and High Dose Rate brachytherapy treatments. This goal will be achieved through a 16-fibre sensor system. Each fibre tip has been engineered to house a small volume of scintillating material to allow for measurements of the delivered dose. The instrument is based on Silicon Photomultipliers detectors, with a solution fully qualified on a single fibre prototype and currently being scaled up through the use of the CITIROC1A ASIC by WEEROC, embedded in the FERS-DT5202 scalable platform designed by CAEN S.p.A. The key features for a system such as ORIGIN, which aims to perform dose measurements in a clinical environment, are fibre response uniformity, system stability, high sensitivity, and perfect reproducibility. The commissioning of the 16-channel dosimeter system in laboratory conditions, with an X-ray cabinet, demonstrated reproducibility of measurements with deviations below 1% after the equalization procedure of the 16 sensors. Finally, the system performance, evaluated in clinical conditions (High Dose Rate centre, Belfast Hospital), allowed for valuable insight into the possible systematics which are present in the current system while simultaneously corroborating the validity of the equalization procedure.
- 22 November 2022
- Published by Sissa Medialab Srl
- Vol. 414, 846
Open AccessA 16-sensor prototype for brachytherapy in vivo dosimetry characterization
The ORIGIN project (Optical Fiber Dose Imaging for Adaptive Brachytherapy) targets the production and qualification of a real-time radiation dose imaging and source localization system for both Low Dose Rate and High Dose Rate brachytherapy treatments. This goal will be achieved through a 16-fibre sensor system. Each fibre tip has been engineered to house a small volume of scintillating material to allow for measurements of the delivered dose. The instrument is based on Silicon Photomultipliers detectors, with a solution fully qualified on a single fibre prototype and currently being scaled up through the use of the CITIROC1A ASIC by WEEROC, embedded in the FERS-DT5202 scalable platform designed by CAEN S.p.A. The key features for a system such as ORIGIN, which aims to perform dose measurements in a clinical environment, are fibre response uniformity, system stability, high sensitivity, and perfect reproducibility. The commissioning of the 16-channel dosimeter system in laboratory conditions, with an X-ray cabinet, demonstrated reproducibility of measurements with deviations below 1% after the equalization procedure of the 16 sensors. Finally, the system performance, evaluated in clinical conditions (High Dose Rate centre, Belfast Hospital), allowed for valuable insight into the possible systematics which are present in the current system while simultaneously corroborating the validity of the equalization procedure.
- Open Access
- 8 October 2022
- Published by MDPI AG in Instruments
- Vol. 6 (4) , 59
SiPMs for Dual-Readout Calorimetry
A new fibre-sampling dual-readout calorimeter prototype has been qualified on beam at two facilities (DESY and CERN) using electrons from 1 to 100 GeV. The prototype was designed to almost fully contain electromagnetic showers and a central module (highly granular readout) was equipped with 320 Silicon Photomultipliers (SiPMs) spaced by 2 mm and individually read out. The test beams performed in 2021, allowed to qualify the readout boards used to operate the SiPMs, to define the calibration procedure and to measure the light yield for scintillating and Cherenkov signals produced by the shower development. This paper reports the first results obtained with the highly granular readout and discusses the ongoing R&D to address some open questions concerning the mechanical integration and the scalable readout scheme that will allow to build and operate the next prototype designed for hadronic showers containment.
- 8 October 2022
- Published by MDPI AG in Instruments
- Vol. 6 (4) , 59
Open AccessSiPMs for Dual-Readout Calorimetry
A new fibre-sampling dual-readout calorimeter prototype has been qualified on beam at two facilities (DESY and CERN) using electrons from 1 to 100 GeV. The prototype was designed to almost fully contain electromagnetic showers and a central module (highly granular readout) was equipped with 320 Silicon Photomultipliers (SiPMs) spaced by 2 mm and individually read out. The test beams performed in 2021, allowed to qualify the readout boards used to operate the SiPMs, to define the calibration procedure and to measure the light yield for scintillating and Cherenkov signals produced by the shower development. This paper reports the first results obtained with the highly granular readout and discusses the ongoing R&D to address some open questions concerning the mechanical integration and the scalable readout scheme that will allow to build and operate the next prototype designed for hadronic showers containment.
- Open Access
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (10) , 2197-2203
Impact of the Detected Scintillation Light Intensity on Neutron-Gamma Discrimination
This paper reports the method and the results of a study on the impact of the detected light intensity on gamma-neutron discrimination. In particular, the minimum number of photons required to achieve a statistically significant separation was measured and shown to be stable against a variation of the Photon Detection Efficiency (PDE) of the system under study. The method, developed using an EJ-276 scintillator bar coupled to a Silicon Photomultiplier (SiPM), is of general interest. For this specific system, the minimum statistics was measured to be 317 ± 16 photons, corresponding to different values of the deposited energy, as the PDE was changed.
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (10) , 2197-2203
Open AccessImpact of the Detected Scintillation Light Intensity on Neutron-Gamma Discrimination
This paper reports the method and the results of a study on the impact of the detected light intensity on gamma-neutron discrimination. In particular, the minimum number of photons required to achieve a statistically significant separation was measured and shown to be stable against a variation of the Photon Detection Efficiency (PDE) of the system under study. The method, developed using an EJ-276 scintillator bar coupled to a Silicon Photomultiplier (SiPM), is of general interest. For this specific system, the minimum statistics was measured to be 317 ± 16 photons, corresponding to different values of the deposited energy, as the PDE was changed.
- 1 May 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (05) , C05053
Qualification of a compact neutron detector based on SiPM
- 1 May 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (05) , C05053
Qualification of a compact neutron detector based on SiPM