Preliminary tribological evaluation of nanostructured diamond coatings against ultra‐high molecular weight polyethylene
- 12 September 2007
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 85B (1) , 140-148
Abstract
Background: Some loss of joint prostheses has been attributed to osteolytic loosening associated with debris from wear of polyethylene articulating against metal alloys. Reduced polyethylene wear has been reported with ceramics serving as an alternative counterface. Methods: Nanostructured Diamond (NSD) coatings were deposited onto Ti6Al4V by microwave plasma‐assisted chemical vapor deposition, with both hydrogen‐rich (H‐NSD) and helium‐rich (He‐NSD) feedgas mixtures. Pin‐on‐disk wear tests of polyethylene against NSD and CoCr were performed in serum lubrication at body temperature. Scanning electron microscopy was used to examine surface morphology, and nanoindentation was used to determine hardness and modulus of the polyethylene wear surfaces. Raman spectroscopy, surface roughness, and wettability analyses of the NSD coatings were performed. Results: Raman spectroscopy confirmed sp2 and sp3 bonded carbon in the NSD coatings. No significant differences in wear factors were found between polyethylene on H‐NSD, He‐NSD, and CoCr, despite higher roughness and friction coefficients for the He‐NSD and H‐NSD coatings, compared with CoCr. Contact angles for the diamond coatings were reduced following the wear tests, indicating that these surfaces became more hydrophilic. Numerous small protuberances were observed on pins articulated against CoCr, and a single, large protuberance was observed in polyethylene‐on‐NSD. These features were conjectured to be reconsolidated polyethylene particles. Nanoindentation modulus and hardness of the worn polyethylene surfaces were lower for polyethylene‐on‐diamond than for polyethylene‐on‐CoCr. Conclusions: As a counterface to polyethylene, NSD‐coated Ti6Al4V produced wear factors comparable to CoCr in the present pin‐on‐disk tests, a promising step towards its use in joint replacement bearing applications. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008Keywords
This publication has 47 references indexed in Scilit:
- A Facile Method for Construction of Antifouling Surfaces by Self-Assembled Polymeric Monolayers of PEG-Silane Copolymers Formed in Aqueous MediumJournal of Nanoscience and Nanotechnology, 2006
- Effect of low protein concentration lubricants in hip simulatorsJournal of Orthopaedic Science, 2006
- Nanostructured diamond film deposition on curved surfaces of metallic temporomandibular joint implantJournal of Physics D: Applied Physics, 2002
- Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: Effects of counterface material, contact area, and lubricantJournal of Biomedical Materials Research, 1999
- Potential thermal artifacts in hip joint wear simulatorsJournal of Biomedical Materials Research, 1999
- In vivo wear of ceramics-polyethylene in comparison with metal-polyethyleneDer Orthopäde, 1997
- Role of cyclic plastic deformation in the wear of UHMWPE acetabular cupsJournal of Biomedical Materials Research, 1995
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsJournal of Materials Research, 1992
- The Mechanism of Loosening of Cemented Acetabular Components in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1992
- Raman scattering characterization of carbon bonding in diamond and diamondlike thin filmsJournal of Vacuum Science & Technology A, 1988