Alan W. Eberhardt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alan W. Eberhardt has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Jack E Lemons
Department of Prosthodontics and Dental Biomaterials, University of Alabama at Birmingham, SDB 616, 1919 7th Avenue South, Birmingham, AL 35294, USA
2 shared publicationsJohn M Cuckler
Alabama Spine and Joint Center, 1709 Somerset Circle, Mountain Brook, AL 35213, USA
2 shared publicationsPreston R Beck
Department of Prosthodontics and Dental Biomaterials, University of Alabama at Birmingham, SDB 616, 1919 7th Avenue South, Birmingham, AL 35294, USA
2 shared publicationsAndrei Stanishevsky
Department of Physics, University of Alabama at Birmingham, Birmingham, Alabama
1 shared publicationAndrew S. Curry
Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, USA
1 shared publication- Brandon A. Sherrod
Department of Neurosurgery, Division of Pediatric Neurosurgery, The University of Alabama at Birmingham and Children's Hospital of Alabama, Birmingham, AL
1 shared publication
Latest Publications
- Open Access
- 29 November 2019
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 23 (1) , 1-7
3D printed mesh reinforcements enhance the mechanical properties of electrospun scaffolds
Background: There is substantial interest in electrospun scaffolds as substrates for tissue regeneration and repair due to their fibrous, extracellular matrix-like composition with interconnected porosity, cost-effective production, and scalability. However, a common limitation of these scaffolds is their inherently low mechanical strength and stiffness, restricting their use in some clinical applications. In this study we developed a novel technique for 3D printing a mesh reinforcement on electrospun scaffolds to improve their mechanical properties. Methods: A poly (lactic acid) (PLA) mesh was 3D-printed directly onto electrospun scaffolds composed of a 40:60 ratio of poly(ε-caprolactone) (PCL) to gelatin, respectively. PLA grids were printed onto the electrospun scaffolds with either a 6 mm or 8 mm distance between the struts. Scanning electron microscopy was utilized to determine if the 3D printing process affected the archtitecture of the electrospun scaffold. Tensile testing was used to ascertain mechanical properties (strength, modulus, failure stress, ductility) of both unmodified and reinforced electrospun scaffolds. An in vivo bone graft model was used to assess biocompatibility. Specifically, reinforced scaffolds were used as a membrane cover for bone graft particles implanted into rat calvarial defects, and implant sites were examined histologically. Results: We determined that the tensile strength and elastic modulus were markedly increased, and ductility reduced, by the addition of the PLA meshes to the electrospun scaffolds. Furthermore, the scaffolds maintained their matrix-like structure after being reinforced with the 3D printed PLA. There was no indication at the graft/tissue interface that the reinforced electrospun scaffolds elicited an immune or foreign body response upon implantation into rat cranial defects. Conclusion: 3D-printed mesh reinforcements offer a new tool for enhancing the mechanical strength of electrospun scaffolds while preserving the advantageous extracellular matrix-like architecture. The modification of electrospun scaffolds with 3D-printed reinforcements is expected to expand the range of clinical applications for which electrospun materials may be suitable.
- 29 November 2019
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 23 (1) , 1-7
Open Access3D printed mesh reinforcements enhance the mechanical properties of electrospun scaffolds
Background: There is substantial interest in electrospun scaffolds as substrates for tissue regeneration and repair due to their fibrous, extracellular matrix-like composition with interconnected porosity, cost-effective production, and scalability. However, a common limitation of these scaffolds is their inherently low mechanical strength and stiffness, restricting their use in some clinical applications. In this study we developed a novel technique for 3D printing a mesh reinforcement on electrospun scaffolds to improve their mechanical properties. Methods: A poly (lactic acid) (PLA) mesh was 3D-printed directly onto electrospun scaffolds composed of a 40:60 ratio of poly(ε-caprolactone) (PCL) to gelatin, respectively. PLA grids were printed onto the electrospun scaffolds with either a 6 mm or 8 mm distance between the struts. Scanning electron microscopy was utilized to determine if the 3D printing process affected the archtitecture of the electrospun scaffold. Tensile testing was used to ascertain mechanical properties (strength, modulus, failure stress, ductility) of both unmodified and reinforced electrospun scaffolds. An in vivo bone graft model was used to assess biocompatibility. Specifically, reinforced scaffolds were used as a membrane cover for bone graft particles implanted into rat calvarial defects, and implant sites were examined histologically. Results: We determined that the tensile strength and elastic modulus were markedly increased, and ductility reduced, by the addition of the PLA meshes to the electrospun scaffolds. Furthermore, the scaffolds maintained their matrix-like structure after being reinforced with the 3D printed PLA. There was no indication at the graft/tissue interface that the reinforced electrospun scaffolds elicited an immune or foreign body response upon implantation into rat cranial defects. Conclusion: 3D-printed mesh reinforcements offer a new tool for enhancing the mechanical strength of electrospun scaffolds while preserving the advantageous extracellular matrix-like architecture. The modification of electrospun scaffolds with 3D-printed reinforcements is expected to expand the range of clinical applications for which electrospun materials may be suitable.
- 20 September 2016
- Published by Taylor & Francis in Assistive Technology
- Vol. 29 (2) , 61-67
Design and validation of a low cost, high-capacity weighing device for wheelchair users and bariatrics
Accessible high-capacity weighing scales are scarce in healthcare facilities, in part due to high device cost and weight. This shortage impairs weight monitoring and health maintenance for people with disabilities and/or morbid obesity. We conducted this study to design and validate a lighter, lower cost, high-capacity accessible weighing device. A prototype featuring 360 kg (800 lbs) of weight capacity, a wheelchair-accessible ramp, and wireless data transmission was fabricated. Forty-five participants (20 standing, 20 manual wheelchair users, and five power wheelchair users) were weighed using the prototype and a calibrated scale. Participants were surveyed to assess perception of each weighing device and the weighing procedure. Weight measurements between devices demonstrated a strong linear correlation (R2 = 0.997) with absolute differences of 1.4 ± 2.0% (mean±SD). Participant preference ratings showed no difference between devices. The prototype weighed 11 kg (38%) less than the next lightest high-capacity commercial device found by author survey. The prototype’s estimated commercial price range, $500–$600, is approximately half the price of the least expensive commercial device found by author survey. Such low cost weighing devices may improve access to weighing instrumentation, which may in turn help eliminate current health disparities. Future work is needed to determine the feasibility of market transition.
- 20 September 2016
- Published by Taylor & Francis in Assistive Technology
- Vol. 29 (2) , 61-67
Design and validation of a low cost, high-capacity weighing device for wheelchair users and bariatrics
Accessible high-capacity weighing scales are scarce in healthcare facilities, in part due to high device cost and weight. This shortage impairs weight monitoring and health maintenance for people with disabilities and/or morbid obesity. We conducted this study to design and validate a lighter, lower cost, high-capacity accessible weighing device. A prototype featuring 360 kg (800 lbs) of weight capacity, a wheelchair-accessible ramp, and wireless data transmission was fabricated. Forty-five participants (20 standing, 20 manual wheelchair users, and five power wheelchair users) were weighed using the prototype and a calibrated scale. Participants were surveyed to assess perception of each weighing device and the weighing procedure. Weight measurements between devices demonstrated a strong linear correlation (R2 = 0.997) with absolute differences of 1.4 ± 2.0% (mean±SD). Participant preference ratings showed no difference between devices. The prototype weighed 11 kg (38%) less than the next lightest high-capacity commercial device found by author survey. The prototype’s estimated commercial price range, $500–$600, is approximately half the price of the least expensive commercial device found by author survey. Such low cost weighing devices may improve access to weighing instrumentation, which may in turn help eliminate current health disparities. Future work is needed to determine the feasibility of market transition.
- 7 June 2016
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 138 (7) , 070803-0708035
Team-Based Development of Medical Devices: An Engineering–Business Collaborative
There is a global shift in the teaching methodology of science and engineering toward multidisciplinary, team-based processes. To meet the demands of an evolving technical industry and lead the way in engineering education, innovative curricula are essential. This paper describes the development of multidisciplinary, team-based learning environments in undergraduate and graduate engineering curricula focused on medical device design. In these programs, students actively collaborate with clinicians, professional engineers, business professionals, and their peers to develop innovative solutions to real-world problems. In the undergraduate senior capstone courses, teams of biomedical engineering (BME) and business students have produced and delivered numerous functional prototypes to satisfied clients. Pursuit of commercialization of devices has led to intellectual property (IP) disclosures and patents. Assessments have indicated high levels of success in attainment of student learning outcomes and student satisfaction with their undergraduate design experience. To advance these projects toward commercialization and further promote innovative team-based learning, a Master of Engineering (MEng) in Design and Commercialization was recently launched. The MEng facilitates teams of graduate students in engineering, life sciences, and business who engage in innovation-commercialization (IC) projects and coursework that take innovative ideas through research and development (R&D) to create marketable devices. The activities are structured with students working together as a “virtual company,” with targeted outcomes of commercialization (license agreements and new start-ups), competitive job placement, and/or career advancement.
- 7 June 2016
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 138 (7) , 070803-0708035
Team-Based Development of Medical Devices: An Engineering–Business Collaborative
There is a global shift in the teaching methodology of science and engineering toward multidisciplinary, team-based processes. To meet the demands of an evolving technical industry and lead the way in engineering education, innovative curricula are essential. This paper describes the development of multidisciplinary, team-based learning environments in undergraduate and graduate engineering curricula focused on medical device design. In these programs, students actively collaborate with clinicians, professional engineers, business professionals, and their peers to develop innovative solutions to real-world problems. In the undergraduate senior capstone courses, teams of biomedical engineering (BME) and business students have produced and delivered numerous functional prototypes to satisfied clients. Pursuit of commercialization of devices has led to intellectual property (IP) disclosures and patents. Assessments have indicated high levels of success in attainment of student learning outcomes and student satisfaction with their undergraduate design experience. To advance these projects toward commercialization and further promote innovative team-based learning, a Master of Engineering (MEng) in Design and Commercialization was recently launched. The MEng facilitates teams of graduate students in engineering, life sciences, and business who engage in innovation-commercialization (IC) projects and coursework that take innovative ideas through research and development (R&D) to create marketable devices. The activities are structured with students working together as a “virtual company,” with targeted outcomes of commercialization (license agreements and new start-ups), competitive job placement, and/or career advancement.
- Open Access
- 8 April 2016
- Published by Taylor & Francis in Assistive Technology
- Vol. 28 (4) , 225-232
Navigation of a virtual exercise environment with Microsoft Kinect by people post-stroke or with cerebral palsy
One approach to encourage and facilitate exercise is through interaction with virtual environments. The present study assessed the utility of Microsoft Kinect as an interface for choosing between multiple routes within a virtual environment through body gestures and voice commands. The approach was successfully tested on 12 individuals post-stroke and 15 individuals with cerebral palsy (CP). Participants rated their perception of difficulty in completing each gesture using a 5-point Likert scale questionnaire. The “most viable” gestures were defined as those with average success rates of 90% or higher and perception of difficulty ranging between easy and very easy. For those with CP, hand raises, hand extensions, and head nod gestures were found most viable. For those post-stroke, the most viable gestures were torso twists, head nods, as well as hand raises and hand extensions using the less impaired hand. Voice commands containing two syllables were viable (>85% successful) for those post-stroke; however, participants with CP were unable to complete any voice commands with a high success rate. This study demonstrated that Kinect may be useful for persons with mobility impairments to interface with virtual exercise environments, but the effectiveness of the various gestures depends upon the disability of the user.
- 8 April 2016
- Published by Taylor & Francis in Assistive Technology
- Vol. 28 (4) , 225-232
Open AccessNavigation of a virtual exercise environment with Microsoft Kinect by people post-stroke or with cerebral palsy
One approach to encourage and facilitate exercise is through interaction with virtual environments. The present study assessed the utility of Microsoft Kinect as an interface for choosing between multiple routes within a virtual environment through body gestures and voice commands. The approach was successfully tested on 12 individuals post-stroke and 15 individuals with cerebral palsy (CP). Participants rated their perception of difficulty in completing each gesture using a 5-point Likert scale questionnaire. The “most viable” gestures were defined as those with average success rates of 90% or higher and perception of difficulty ranging between easy and very easy. For those with CP, hand raises, hand extensions, and head nod gestures were found most viable. For those post-stroke, the most viable gestures were torso twists, head nods, as well as hand raises and hand extensions using the less impaired hand. Voice commands containing two syllables were viable (>85% successful) for those post-stroke; however, participants with CP were unable to complete any voice commands with a high success rate. This study demonstrated that Kinect may be useful for persons with mobility impairments to interface with virtual exercise environments, but the effectiveness of the various gestures depends upon the disability of the user.
- 1 October 2012
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 134 (10) , 104503
A Novel Device to Quantify the Mechanical Properties of Electrospun Nanofibers
Mechanical deformation of cell-seeded electrospun matrices plays an important role in cell signaling. However, electrospun biomaterials have inherently complex geometries due to the random deposition of fibers during the electrospinning process. This confounds attempts at quantifying strains exerted on adherent cells during electrospun matrix deformation. We have developed a novel mechanical test platform that allows deposition and tensile testing of electrospun fibers in a highly parallel arrangement to simplify mechanical analysis of the fibers alone and with adherent cells. The device is capable of optically recording fiber strain in a cell culture environment. Here we report on the mechanical and viscoelastic properties of highly parallel electrospun poly(ε-caprolactone) fibers. Force-strain data derived from this device will drive the development of cellular mechanotransduction studies as well as the customization of electrospun matrices for specific engineered tissue applications.
- 1 October 2012
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 134 (10) , 104503
A Novel Device to Quantify the Mechanical Properties of Electrospun Nanofibers
Mechanical deformation of cell-seeded electrospun matrices plays an important role in cell signaling. However, electrospun biomaterials have inherently complex geometries due to the random deposition of fibers during the electrospinning process. This confounds attempts at quantifying strains exerted on adherent cells during electrospun matrix deformation. We have developed a novel mechanical test platform that allows deposition and tensile testing of electrospun fibers in a highly parallel arrangement to simplify mechanical analysis of the fibers alone and with adherent cells. The device is capable of optically recording fiber strain in a cell culture environment. Here we report on the mechanical and viscoelastic properties of highly parallel electrospun poly(ε-caprolactone) fibers. Force-strain data derived from this device will drive the development of cellular mechanotransduction studies as well as the customization of electrospun matrices for specific engineered tissue applications.
- Open Access
- 6 March 2012
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 14 (2) , R49
Altered responsiveness to TGF-β results in reduced Papss2 expression and alterations in the biomechanical properties of mouse articular cartilage
Introduction: Previous studies have indicated that transforming growth factor β (TGF-β) signaling has a critical role in cartilage homeostasis and repair, yet the mechanisms of TGF-β's chondroprotective effects are not known. Our objective in this study was to identify downstream targets of TGF-β that could act to maintain biochemical and biomechanical properties of cartilage. Methods: Tibial joints from 20-week-old mice that express a dominant-negative mutation of the TGF-β type II receptor (DNIIR) were graded histologically for osteoarthritic changes and tested by indentation to evaluate their mechanical properties. To identify gene targets of TGF-β, microarray analysis was performed using bovine articular chondrocytes grown in micromass culture that were either treated with TGF-β or left untreated. Phosphoadenosine phosphosynthetase 2 (PAPSS2) was identified as a TGF-β-responsive gene. Papss2 expression is crucial for proper sulfation of cartilage matrix, and its deficiency causes skeletal defects in mice and humans that overlap with those seen in mice with mutations in TGF-β-signaling genes. Regulation of Papss2 was verified by real time RT-PCR and Western blot analyses. Alterations in sulfation of glycosaminoglycans were analyzed by critical electrolyte concentration and Alcian blue staining and immunofluorescence for chondroitin-4-sulfate, unsulfated chondroitin and the aggrecan core protein. Results: DNIIR mutants showed reduced mechanical properties and osteoarthritis-like changes when compared to wild-type control mice. Microarray analysis identified a group of genes encoding matrix-modifying enzymes that were regulated by TGF-β. Papss2 was upregulated in bovine articular chondrocytes after treatment with TGF-β and downregulated in cartilage from DNIIR mice. Articular cartilage in DNIIR mice demonstrated reduced Alcian blue staining at critical electrolyte concentrations and reduced chondroitin-4-sulfate staining. Staining for unsulfated chondroitin sulfate was increased, whereas staining for the aggrecan core protein was comparable in DNIIR and wild-type mice. Conclusion: TGF-β maintains biomechanical properties and regulates expression of Papss2 and sulfation of glycosaminoglycans in mouse articular cartilage.
- 6 March 2012
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 14 (2) , R49
Open AccessAltered responsiveness to TGF-β results in reduced Papss2 expression and alterations in the biomechanical properties of mouse articular cartilage
Introduction: Previous studies have indicated that transforming growth factor β (TGF-β) signaling has a critical role in cartilage homeostasis and repair, yet the mechanisms of TGF-β's chondroprotective effects are not known. Our objective in this study was to identify downstream targets of TGF-β that could act to maintain biochemical and biomechanical properties of cartilage. Methods: Tibial joints from 20-week-old mice that express a dominant-negative mutation of the TGF-β type II receptor (DNIIR) were graded histologically for osteoarthritic changes and tested by indentation to evaluate their mechanical properties. To identify gene targets of TGF-β, microarray analysis was performed using bovine articular chondrocytes grown in micromass culture that were either treated with TGF-β or left untreated. Phosphoadenosine phosphosynthetase 2 (PAPSS2) was identified as a TGF-β-responsive gene. Papss2 expression is crucial for proper sulfation of cartilage matrix, and its deficiency causes skeletal defects in mice and humans that overlap with those seen in mice with mutations in TGF-β-signaling genes. Regulation of Papss2 was verified by real time RT-PCR and Western blot analyses. Alterations in sulfation of glycosaminoglycans were analyzed by critical electrolyte concentration and Alcian blue staining and immunofluorescence for chondroitin-4-sulfate, unsulfated chondroitin and the aggrecan core protein. Results: DNIIR mutants showed reduced mechanical properties and osteoarthritis-like changes when compared to wild-type control mice. Microarray analysis identified a group of genes encoding matrix-modifying enzymes that were regulated by TGF-β. Papss2 was upregulated in bovine articular chondrocytes after treatment with TGF-β and downregulated in cartilage from DNIIR mice. Articular cartilage in DNIIR mice demonstrated reduced Alcian blue staining at critical electrolyte concentrations and reduced chondroitin-4-sulfate staining. Staining for unsulfated chondroitin sulfate was increased, whereas staining for the aggrecan core protein was comparable in DNIIR and wild-type mice. Conclusion: TGF-β maintains biomechanical properties and regulates expression of Papss2 and sulfation of glycosaminoglycans in mouse articular cartilage.
- Open Access
- 1 January 2009
- Published by Wiley in International Journal of Biomaterials
- Vol. 2009 (1) , 185456
Surface Roughness of CoCr and ZrO2 Femoral Heads with Metal Transfer: A Retrieval and Wear Simulator Study
Metal transfer to femoral heads may result from impingement against the metallic acetabular shell following subluxation/dislocation, or when metallic debris enters the articulation zone. Such transfers roughen the head surface, increasing polyethylene wear in total hip replacements. Presently, we examined the surface roughness of retrieved femoral heads with metallic transfer. Profilometry revealed roughness averages in regions of metal transfer averaging 0.380 μm for CoCr and 0.294 μm for ZrO2 which were one order of magnitude higher than those from non‐implanted controls. Scanning electron microscopy (SEM) revealed adherent transfers on these retrievals, with titanium presence confirmed by electron dispersive spectroscopy. Due to the concern for increased wear, metal transfer was induced on non‐implanted heads, which were then articulated against flat polyethylene discs in multidirectional sliding wear tests. Increased polyethylene wear was associated with these specimens as compared to unaltered controls. SEM imaging provided visual evidence that the transfers remained adherent following the wear tests. Pre‐ and post‐test roughness averages exceeded 1 μm for both the CoCr and ZrO2 heads. Overall, these results suggest that metal transfer increases the surface roughness of CoCr and ZrO2 femoral heads and that the transfers may remain adherent following articulation against polyethylene, leading to increased polyethylene wear.
- 1 January 2009
- Published by Wiley in International Journal of Biomaterials
- Vol. 2009 (1) , 185456
Open AccessSurface Roughness of CoCr and ZrO2 Femoral Heads with Metal Transfer: A Retrieval and Wear Simulator Study
Metal transfer to femoral heads may result from impingement against the metallic acetabular shell following subluxation/dislocation, or when metallic debris enters the articulation zone. Such transfers roughen the head surface, increasing polyethylene wear in total hip replacements. Presently, we examined the surface roughness of retrieved femoral heads with metallic transfer. Profilometry revealed roughness averages in regions of metal transfer averaging 0.380 μm for CoCr and 0.294 μm for ZrO2 which were one order of magnitude higher than those from non‐implanted controls. Scanning electron microscopy (SEM) revealed adherent transfers on these retrievals, with titanium presence confirmed by electron dispersive spectroscopy. Due to the concern for increased wear, metal transfer was induced on non‐implanted heads, which were then articulated against flat polyethylene discs in multidirectional sliding wear tests. Increased polyethylene wear was associated with these specimens as compared to unaltered controls. SEM imaging provided visual evidence that the transfers remained adherent following the wear tests. Pre‐ and post‐test roughness averages exceeded 1 μm for both the CoCr and ZrO2 heads. Overall, these results suggest that metal transfer increases the surface roughness of CoCr and ZrO2 femoral heads and that the transfers may remain adherent following articulation against polyethylene, leading to increased polyethylene wear.
- 1 November 2008
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (11) , 2499-2504
Early Failure of a Cross-Linked Polyethylene Acetabular Liner
The use of highly cross-linked ultra-high molecular weight polyethylene in total hip arthroplasty has become a popular alternative to the use of conventional polyethylene. Evaluations with use of hip simulator tests1-4 and clinical evaluations of total hip replacements5-10 have independently shown t
- 1 November 2008
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (11) , 2499-2504
Early Failure of a Cross-Linked Polyethylene Acetabular Liner
The use of highly cross-linked ultra-high molecular weight polyethylene in total hip arthroplasty has become a popular alternative to the use of conventional polyethylene. Evaluations with use of hip simulator tests1-4 and clinical evaluations of total hip replacements5-10 have independently shown t
- 12 September 2007
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 85B (1) , 140-148
Preliminary tribological evaluation of nanostructured diamond coatings against ultra‐high molecular weight polyethylene
Background: Some loss of joint prostheses has been attributed to osteolytic loosening associated with debris from wear of polyethylene articulating against metal alloys. Reduced polyethylene wear has been reported with ceramics serving as an alternative counterface. Methods: Nanostructured Diamond (NSD) coatings were deposited onto Ti6Al4V by microwave plasma‐assisted chemical vapor deposition, with both hydrogen‐rich (H‐NSD) and helium‐rich (He‐NSD) feedgas mixtures. Pin‐on‐disk wear tests of polyethylene against NSD and CoCr were performed in serum lubrication at body temperature. Scanning electron microscopy was used to examine surface morphology, and nanoindentation was used to determine hardness and modulus of the polyethylene wear surfaces. Raman spectroscopy, surface roughness, and wettability analyses of the NSD coatings were performed. Results: Raman spectroscopy confirmed sp2 and sp3 bonded carbon in the NSD coatings. No significant differences in wear factors were found between polyethylene on H‐NSD, He‐NSD, and CoCr, despite higher roughness and friction coefficients for the He‐NSD and H‐NSD coatings, compared with CoCr. Contact angles for the diamond coatings were reduced following the wear tests, indicating that these surfaces became more hydrophilic. Numerous small protuberances were observed on pins articulated against CoCr, and a single, large protuberance was observed in polyethylene‐on‐NSD. These features were conjectured to be reconsolidated polyethylene particles. Nanoindentation modulus and hardness of the worn polyethylene surfaces were lower for polyethylene‐on‐diamond than for polyethylene‐on‐CoCr. Conclusions: As a counterface to polyethylene, NSD‐coated Ti6Al4V produced wear factors comparable to CoCr in the present pin‐on‐disk tests, a promising step towards its use in joint replacement bearing applications. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008
- 12 September 2007
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 85B (1) , 140-148
Preliminary tribological evaluation of nanostructured diamond coatings against ultra‐high molecular weight polyethylene
Background: Some loss of joint prostheses has been attributed to osteolytic loosening associated with debris from wear of polyethylene articulating against metal alloys. Reduced polyethylene wear has been reported with ceramics serving as an alternative counterface. Methods: Nanostructured Diamond (NSD) coatings were deposited onto Ti6Al4V by microwave plasma‐assisted chemical vapor deposition, with both hydrogen‐rich (H‐NSD) and helium‐rich (He‐NSD) feedgas mixtures. Pin‐on‐disk wear tests of polyethylene against NSD and CoCr were performed in serum lubrication at body temperature. Scanning electron microscopy was used to examine surface morphology, and nanoindentation was used to determine hardness and modulus of the polyethylene wear surfaces. Raman spectroscopy, surface roughness, and wettability analyses of the NSD coatings were performed. Results: Raman spectroscopy confirmed sp2 and sp3 bonded carbon in the NSD coatings. No significant differences in wear factors were found between polyethylene on H‐NSD, He‐NSD, and CoCr, despite higher roughness and friction coefficients for the He‐NSD and H‐NSD coatings, compared with CoCr. Contact angles for the diamond coatings were reduced following the wear tests, indicating that these surfaces became more hydrophilic. Numerous small protuberances were observed on pins articulated against CoCr, and a single, large protuberance was observed in polyethylene‐on‐NSD. These features were conjectured to be reconsolidated polyethylene particles. Nanoindentation modulus and hardness of the worn polyethylene surfaces were lower for polyethylene‐on‐diamond than for polyethylene‐on‐CoCr. Conclusions: As a counterface to polyethylene, NSD‐coated Ti6Al4V produced wear factors comparable to CoCr in the present pin‐on‐disk tests, a promising step towards its use in joint replacement bearing applications. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008