Fabrication of a piezoelectric array for use in a dual frequency hybrid piezoelectric—CMUT probe
Open Access
- 11 June 2025
- journal article
- research article
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (9) , 2641-2656
Abstract
Wideband transducers are highly preferable for medical ultrasound imaging. Dual-frequency transducers have been developed to enlarge the operating bandwidth by separating transmission and reception. A novel dual-frequency transducer design, comprising a hybrid configuration of a partly epoxy-filled kerf piezoelectric array and a capacitive micromachined ultrasound transducer (CMUT) array, has been proposed. This work studied the fabrication feasibility such hybrid transducer, including both fabrication of the partly epoxy-filled piezoelectric array and lamination of inactive CMUTs to this array to mimic the hybrid transducer. The bonding properties of piezoelectric elements on a flexible printed circuit board were characterized through both mechanical and electrical methods. The adhesion strength of elements to the flexible printed circuit board demonstrates robustness, with a peel strength reaching up to 2.7 N/mm. Additionally, the contact resistance of an element to the board is negligibly small, approximately 0.11 Ω. Four prototype arrays, each consisting of 80 elements with air-filled kerfs, were successfully fabricated, achieving a yield ratio up to 100%. The lamination process was successfully performed, resulting in a shear strength above 4.2 MPa and maintaining an epoxy fill less than 30% in the kerfs.Keywords
Funding Information
- The Research Council of Norway, CIUS (4700040-10)
- The Research Council of Norway, CFRON (317769)
- NorFab (295864)
- University of South-Eastern Norway
This publication has 37 references indexed in Scilit:
- Transducers and Arrays for Underwater Sound2016
- Transfer of thin Au films to polydimethylsiloxane (PDMS) with reliable bonding using (3-mercaptopropyl)trimethoxysilane (MPTMS) as a molecular adhesiveJournal of Micromechanics and Microengineering, 2013
- Micromachined Ultrasonic Transducers2008
- High-density flexible interconnect for two-dimensional ultrasound arraysIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2000
- Forty-channel phased array ultrasonic probe using 0.91Pb(Zn/sub 1/3/Nb/sub 2/3/)O/sub 3/-0.09PbTiO/sub 3/ single crystalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999
- Oxidation of tungsten and tungsten carbide in dry and humid atmospheresInternational Journal of Refractory Metals and Hard Materials, 1996
- A 100-MHz ultrasonic transducer array using ZnO thin filmsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- A dual frequency ultrasonic probe for medical applicationsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- Two-dimensional array transducers using thick film connection technologyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1993
- Fabrication and characterization of transducer elements in two-dimensional arrays for medical ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992