Experimental Evaluation of a Thermopile Detector With SU-8 Membrane in a Carbon Dioxide Meter Setup
Authors:
- Claes G. MattssonCMClaes G. Mattsson
- Göran ThungstromGTGöran Thungstrom
- Henrik RodjegardHRHenrik Rodjegard
- Kent BertilssonKent Bertilsson
- Hans-Erik NilssonHNHans-Erik Nilsson
- Hans MartinHMHans Martin
- 20 October 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 9 (12) , 1633-1638
Abstract
Continuous control of the carbon dioxide levels in the ventilation systems in office buildings and public schools has been shown to increase productivity and save money. However, these measurement systems require further developments in order to be more cost effective. This paper presents an evaluation of an Al/Bi thermopile detector with a 4 mum thin SiO2/SU-8 membrane in a CO2 meter application using the nondispersive infrared technology (NDIR). The system consists of an 11 cm aluminum tube, used as the sample chamber and in which a light source and a thermopile detector with a 4.26 mum optical bandpass filter are positioned on its opposite sides. The light source is pulsed with a frequency of 0.5 Hz. The voltage response of the Al/Bi thermopile is measured for different CO2 concentrations, and, as expected according to the Lambert-Beer law, there is an exponential decrease in the measured intensity. The absolute response is about 50% lower than for a commercial HMS J21 thermopile from Heimann Sensor GmbH. In relative terms, on the other hand, the Al/Bi thermopile is more sensitive for changes in the CO2 concentration. At 7500 ppm, the voltage response has decreased to 40% of the reference response measured in the nitrogen atmosphere.Keywords
This publication has 17 references indexed in Scilit:
- Design of a Micromachined Thermopile Infrared Sensor With a Self-Supported ${\rm SiO}_{2}/{\rm SU}{-}8$ MembraneIEEE Sensors Journal, 2008
- Fabrication and evaluation of a thermal sensor formed on a thin photosensitive epoxy membrane with low thermal conductivityJournal of Physics: Conference Series, 2008
- A High-Precision NDIR $\hbox{CO}_{2}$ Gas Sensor for Automotive ApplicationsIEEE Sensors Journal, 2006
- A high-temperature thermopile fabrication process for thermal flow sensorsSensors and Actuators A: Physical, 2006
- The NDIR$hboxCO_2$Monitor With Smart Interface for Global NetworkingIEEE Transactions on Instrumentation and Measurement, 2005
- A numerical simulation tool for infrared thermopile detectors2005
- An electronic nose based on solid state sensor arrays for low-cost indoor air quality monitoring applicationsSensors and Actuators B: Chemical, 2004
- The study of silicon thermopile2002
- A Novel C02 Sensor Based On Changes In Conductivity Of Metal Oxides1995
- Heat transport from a chipIEEE Transactions on Electron Devices, 1990