Fatal air embolism in an extremely low birth weight infant: can it be caused by intravenous injections during resuscitation?

Authors:

Abstract
A preterm infant with a birth weight of 384 g who succumbed to vigorous resuscitation for sudden respiratory failure on the third day of life is presented. Postmortem examination revealed, apart from extensive pulmonary hemorrhage, a fatal amount of air mainly in the right ventricle. We believe that this air had been introduced via peripheral venous cannulas due to inadvertent and unavoidable air admixture to each injection volume administered with a syringe, and we develop an experimental model to confirm that fatal amounts of air can indeed accumulate with frequent change over of syringes within a short period of time.

This publication has 13 references indexed in Scilit: