Fifty-six percent of proximal femoral cortical hypertrophies 6 to 10 years after Total hip arthroplasty with a short Cementless curved hip stem – a cause for concern?
Open Access
- 29 May 2019
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 261
Abstract
Thigh pain and cortical hypertrophies (CH) have been reported in the short term for specific short hip stem designs. The purpose of the study was to investigate 1) the differences in clinical outcome, thigh pain and stem survival for patients with and without CHs and 2) to identify patient and surgery-related factors being associated with the development of CHs. A consecutive series of 233 patients with 246 hips was included in the present retrospective diagnostic cohort study, who had received a total hip arthroplasty (THA) between December 2007 and 2009 with a cementless, curved, short hip stem (Fitmore, Zimmer, Warsaw, IN, USA). Clinical and radiographic follow-up, including the radiographic parameters for hip geometry reconstruction, were prospectively assessed 1, 3, and 6 to 10 years after surgery. Cortical hypertrophies were observed in 56% of the hips after a mean of 7.7 years, compared to 53% after 3.3 years being mostly located in Gruen zone 3 and 5. There was no significant difference for the Harris Hip Score and UCLA score for patients with and without CHs. Only one patient with a mild CH in Gruen zone 5 and extensive heterotopic ossifications around the neck of the stem reported thigh pain. The Kaplan Meier survival rate after 8.6 years was 99.6% (95%-CI; 97.1–99.9%) for stem revision due to aseptic loosening and no association with CHs could be detected. Postoperative increase in hip offset was the only risk factor being associated with the development of CHs in the regression model (ΔHO; OR 1.1 (1.0–1.2); p = 0.001). The percentage of cortical hypertrophies remained almost constant in the mid-term compared to the short-term with the present cementless short hip stem design. The high percentage of cortical hypertrophies seems not be a cause for concern with this specific implant in the mid-term. Diagnostic Level IVKeywords
This publication has 30 references indexed in Scilit:
- Ten year results of the collum femoris preserving total hip replacement: a prospective cohort study of seventy five patientsInternational Orthopaedics, 2013
- Primary stability of the Fitmore® stem: biomechanical comparisonInternational Orthopaedics, 2013
- Long-term (20- to 25-year) Results of an Uncemented Tapered Titanium Femoral Component and Factors Affecting SurvivorshipClinical Orthopaedics and Related Research, 2013
- Eleven-Year Results of the Anatomic Coated CFP Stem in Primary Total Hip ArthroplastyThe Journal of Arthroplasty, 2013
- Short stems for total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2012
- Effect of Restoration of Combined Offset on Stability of Large Head ThaHIP International, 2012
- Hip Offset in Total Hip Arthroplasty: Quantitative Measurement with NavigationClinical Orthopaedics and Related Research, 2011
- Prospective study of a cementless total hip arthroplasty with a collum femoris preserving stem and a trabeculae oriented pressfit cup: minimun 6-year follow-upArchives of orthopaedic and trauma surgery, 2010
- Mid-term results of 155 patients treated with a collum femoris preserving (CFP) short stem prosthesisInternational Orthopaedics, 2010
- Importance of events per independent variable in proportional hazards regression analysis II. Accuracy and precision of regression estimatesJournal of Clinical Epidemiology, 1995