Estimation of the origin of ventricular outflow tract arrhythmia using synthesized right-sided chest leads
Open Access
- 26 November 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (9) , 1373-1378
Abstract
For successful ablation of ventricular outflow tract arrhythmia, estimation of its origin prior to the procedure can be useful. Morphology and lead placement in the right thoracic area may be useful for this purpose. Electrocardiography using synthesized right-sided chest leads (Syn-V3R, Syn-V4R, and Syn-V5R) is performed using standard leads without any additional leads. This study evaluated the usefulness of synthesized right-sided chest leads in estimating the origin of ventricular outflow tract arrhythmia. This retrospective study included 63 patients in whom successful ablation of ventricular outflow tract arrhythmia was performed. Numbers of arrhythmias originating from the left ventricle, the septum of the right ventricle, and the free wall of the right ventricle were 11, 40, and 13, respectively. In one patient, two different left ventricular outflow tract origins were found. Electrocardiographic recordings from right-sided chest leads were divided into three types as follows: those in which an R > S concordance, a transitional zone, or an R < S concordance were detected. In all left arrhythmia cases, R > S concordance was observed. A transitional zone was evident in 34 of 40 cases of right ventricular outflow tract arrhythmia originating in the ventricular septum, and an R < S concordance was observed in 6 of the 40 cases. However, an R < S concordance was found in all cases of right ventricular outflow tract arrhythmia originating in the free wall. Synthesized right-sided chest lead electrocardiography may be useful for estimating the origin of ventricular outflow tract arrhythmia.Keywords
This publication has 15 references indexed in Scilit:
- Recovery from left ventricular dysfunction after ablation of frequent premature ventricular complexesHeart Rhythm, 2013
- Electrocardiographic and electrophysiological characteristics of premature ventricular complexes associated with left ventricular dysfunction in patients without structural heart diseaseEP Europace, 2012
- The V2 Transition RatioJACC, 2011
- Novel transitional zone index allows more accurate differentiation between idiopathic right ventricular outflow tract and aortic sinus cusp ventricular arrhythmiasHeart Rhythm, 2011
- Development and Validation of an ECG Algorithm for Identifying the Optimal Ablation Site for Idiopathic Ventricular Outflow Tract TachycardiaJournal of Cardiovascular Electrophysiology, 2003
- Left ventricular dysfunction resulting from frequent unifocal ventricular ectopics with resolution following radiofrequency ablationEP Europace, 2003
- Repetitive monomorphic ventricular tachycardia originating from the aortic sinus cuspJACC, 2002
- Electrocardiographic Characteristics of Left Ventricular Outflow Tract TachycardiaPacing and Clinical Electrophysiology, 2000
- Localization of Optimal Ablation Site of Idiopathic Ventricular Tachycardia from Right and Left Ventricular Outflow Tract by Body Surface ECGCirculation, 1998
- Radiofrequency catheter ablation as a cure for idiopathic tachycardia of both left and eight ventricular originJACC, 1994