Masahiro Nakano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Masahiro Nakano has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Takatsugu Kajiyama
Department of Advanced Arrhythmia Bioengineering Chiba University Graduate School of Medicine Chiba Japan
6 shared publications Yoshio Kobayashi
Department of Cardiovascular Medicine Chiba University Graduate School of Medicine Chiba Japan
6 shared publicationsYusuke Kondo
Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan
5 shared publicationsMiyo Nakano
Department of Cardiovascular Medicine Chiba University Graduate School of Medicine Chiba Japan
4 shared publicationsMarehiko Ueda
Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670, Japan
3 shared publicationsMari Kitagawa
Department of Cardiovascular Medicine Chiba University Graduate School of Medicine Chiba Japan
3 shared publications
Latest Publications
- 21 June 2023
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (8) , 1665-1670
Junctional rhythm during cryoablation for typical atrioventricular nodal reentrant tachycardia
Introduction: Cryoablation is being used as an alternative to radiofrequency (RF) ablation for atrioventricular nodal reentrant tachycardia (AVNRT) owing to the lower risk of atrioventricular block (AVB) compared to RF ablation. Junctional rhythm often occurs during successful application of RF ablation for AVNRT. In contrast, junctional rhythm has rarely been reported to occur during cryoablation. This retrospective study evaluated the characteristics of junctional rhythm during cryoablation for typical AVNRT.Methods and Results: This retrospective study included 127 patients in whom successful cryoablation of typical AVNRT was performed. Patients diagnosed with atypical AVNRT were excluded. Junctional rhythm appeared during cryofreezing in 22 patients (17.3%). These junctional rhythms appeared due to cryofreezing at the successful site in the early phase within 15 s of commencement of cooling. Transient complete AVB was observed in 10 of 127 patients (7.9%), and it was noted that atrioventricular conduction improved immediately after cooling was stopped in these 10 patients. No junctional rhythm was observed before the appearance of AVB. No recurrence of tachycardia was confirmed in patients in whom junctional rhythm occurred by cryofreezing at the successful site.Conclusion: Occurrence of junctional rhythms during cryoablation is not so rare and can be considered a criterion for successful cryofreezing. Furthermore, junctional rhythm may be associated with low risk of recurrent tachycardia.
- 21 June 2023
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (8) , 1665-1670
Junctional rhythm during cryoablation for typical atrioventricular nodal reentrant tachycardia
Introduction: Cryoablation is being used as an alternative to radiofrequency (RF) ablation for atrioventricular nodal reentrant tachycardia (AVNRT) owing to the lower risk of atrioventricular block (AVB) compared to RF ablation. Junctional rhythm often occurs during successful application of RF ablation for AVNRT. In contrast, junctional rhythm has rarely been reported to occur during cryoablation. This retrospective study evaluated the characteristics of junctional rhythm during cryoablation for typical AVNRT.Methods and Results: This retrospective study included 127 patients in whom successful cryoablation of typical AVNRT was performed. Patients diagnosed with atypical AVNRT were excluded. Junctional rhythm appeared during cryofreezing in 22 patients (17.3%). These junctional rhythms appeared due to cryofreezing at the successful site in the early phase within 15 s of commencement of cooling. Transient complete AVB was observed in 10 of 127 patients (7.9%), and it was noted that atrioventricular conduction improved immediately after cooling was stopped in these 10 patients. No junctional rhythm was observed before the appearance of AVB. No recurrence of tachycardia was confirmed in patients in whom junctional rhythm occurred by cryofreezing at the successful site.Conclusion: Occurrence of junctional rhythms during cryoablation is not so rare and can be considered a criterion for successful cryofreezing. Furthermore, junctional rhythm may be associated with low risk of recurrent tachycardia.
- 14 June 2021
- Published by Elsevier in Journal of Cardiology
- Vol. 78 (5) , 362-367
Pathophysiological background and prognosis of common atrial flutter in non-elderly patients: Comparison to Atrial Fibrillation
- 14 June 2021
- Published by Elsevier in Journal of Cardiology
- Vol. 78 (5) , 362-367
Pathophysiological background and prognosis of common atrial flutter in non-elderly patients: Comparison to Atrial Fibrillation
- Open Access
- 1 November 2020
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 6 (11) , 827-830
Simultaneous conduction disturbance of an atrioventricular accessory pathway and nodal pathway after a mitral valve replacement: A case report
- 1 November 2020
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 6 (11) , 827-830
Open AccessSimultaneous conduction disturbance of an atrioventricular accessory pathway and nodal pathway after a mitral valve replacement: A case report
- 15 November 2019
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 59 (1) , 43-48
Estimation of the accessory pathway location of the manifest Wolf-Parkinson-White syndrome using synthesized right-sided chest leads
The classification using QRS morphology of V1 lead is a useful simple predictor of accessory pathway location (type A, R or Rs pattern; type B, rS pattern; type C, QS or Qr pattern), but often leads to misdiagnosis of accessory pathway location, especially in types B and C. The synthesized 18-lead electrocardiography (ECG) derived from standard 12-lead ECG can provide virtual waveforms of right-sided chest leads. This study aimed to evaluate the usefulness of the right-sided chest lead ECG for prediction of accessory pathway location.
- 15 November 2019
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 59 (1) , 43-48
Estimation of the accessory pathway location of the manifest Wolf-Parkinson-White syndrome using synthesized right-sided chest leads
The classification using QRS morphology of V1 lead is a useful simple predictor of accessory pathway location (type A, R or Rs pattern; type B, rS pattern; type C, QS or Qr pattern), but often leads to misdiagnosis of accessory pathway location, especially in types B and C. The synthesized 18-lead electrocardiography (ECG) derived from standard 12-lead ECG can provide virtual waveforms of right-sided chest leads. This study aimed to evaluate the usefulness of the right-sided chest lead ECG for prediction of accessory pathway location.
- 1 April 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (4) , 654-658
Shortening of the atrial-His bundle interval during atrial pacing as a predictor of successful ablation for typical atrioventricular nodal re-entrant tachycardia
Aims Shortening of the atrial-His bundle (AH) interval during the sinus rhythm is occasionally observed after slow pathway ablation for atrioventricular nodal re-entrant tachycardia (AVNRT). In addition, high-rate atrial pacing is useful for avoiding atrioventricular block. We hypothesized that shortening of the AH interval during slow pathway ablation under high-rate atrial pacing would lead to successful ablation of typical AVNRT. Methods and results This retrospective study included 37 patients in whom successful ablation of typical AVNRT was performed under atrial pacing. The AH interval was measured immediately before the first radiofrequency (RF) application and immediately after the last RF application, prior to the first induction. Twenty-five of 37 patients achieved procedural success at the first induction (i.e. successful group). No patients developed a prolonged AH interval or atrioventricular block. The AH interval was shortened by an average of 14.6 +/- 7.7 and 1.8 +/- 1.2 ms in the successful and other patient groups, respectively (P < 0.01). An AH interval decrease of > 10 ms was observed in 23 of 27 (85%) patients in the successful group, whereas all other patients had an AH interval decrease of < 5 ms. Conclusion Shortening of the AH interval during high-rate atrial pacing is a predictor of the successful ablation for typical AVNRT.
- 1 April 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (4) , 654-658
Shortening of the atrial-His bundle interval during atrial pacing as a predictor of successful ablation for typical atrioventricular nodal re-entrant tachycardia
Aims Shortening of the atrial-His bundle (AH) interval during the sinus rhythm is occasionally observed after slow pathway ablation for atrioventricular nodal re-entrant tachycardia (AVNRT). In addition, high-rate atrial pacing is useful for avoiding atrioventricular block. We hypothesized that shortening of the AH interval during slow pathway ablation under high-rate atrial pacing would lead to successful ablation of typical AVNRT. Methods and results This retrospective study included 37 patients in whom successful ablation of typical AVNRT was performed under atrial pacing. The AH interval was measured immediately before the first radiofrequency (RF) application and immediately after the last RF application, prior to the first induction. Twenty-five of 37 patients achieved procedural success at the first induction (i.e. successful group). No patients developed a prolonged AH interval or atrioventricular block. The AH interval was shortened by an average of 14.6 +/- 7.7 and 1.8 +/- 1.2 ms in the successful and other patient groups, respectively (P < 0.01). An AH interval decrease of > 10 ms was observed in 23 of 27 (85%) patients in the successful group, whereas all other patients had an AH interval decrease of < 5 ms. Conclusion Shortening of the AH interval during high-rate atrial pacing is a predictor of the successful ablation for typical AVNRT.
- Open Access
- 1 September 2015
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 1 (5) , 384-385
Rapidly formed right ventricular thrombus detected by intracardiac echocardiography before catheter ablation in a case of arrhythmogenic right ventricular cardiomyopathy
- 1 September 2015
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 1 (5) , 384-385
Open AccessRapidly formed right ventricular thrombus detected by intracardiac echocardiography before catheter ablation in a case of arrhythmogenic right ventricular cardiomyopathy
- Open Access
- 26 November 2013
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (9) , 1373-1378
Estimation of the origin of ventricular outflow tract arrhythmia using synthesized right-sided chest leads
For successful ablation of ventricular outflow tract arrhythmia, estimation of its origin prior to the procedure can be useful. Morphology and lead placement in the right thoracic area may be useful for this purpose. Electrocardiography using synthesized right-sided chest leads (Syn-V3R, Syn-V4R, and Syn-V5R) is performed using standard leads without any additional leads. This study evaluated the usefulness of synthesized right-sided chest leads in estimating the origin of ventricular outflow tract arrhythmia. This retrospective study included 63 patients in whom successful ablation of ventricular outflow tract arrhythmia was performed. Numbers of arrhythmias originating from the left ventricle, the septum of the right ventricle, and the free wall of the right ventricle were 11, 40, and 13, respectively. In one patient, two different left ventricular outflow tract origins were found. Electrocardiographic recordings from right-sided chest leads were divided into three types as follows: those in which an R > S concordance, a transitional zone, or an R < S concordance were detected. In all left arrhythmia cases, R > S concordance was observed. A transitional zone was evident in 34 of 40 cases of right ventricular outflow tract arrhythmia originating in the ventricular septum, and an R < S concordance was observed in 6 of the 40 cases. However, an R < S concordance was found in all cases of right ventricular outflow tract arrhythmia originating in the free wall. Synthesized right-sided chest lead electrocardiography may be useful for estimating the origin of ventricular outflow tract arrhythmia.
- 26 November 2013
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (9) , 1373-1378
Open AccessEstimation of the origin of ventricular outflow tract arrhythmia using synthesized right-sided chest leads
For successful ablation of ventricular outflow tract arrhythmia, estimation of its origin prior to the procedure can be useful. Morphology and lead placement in the right thoracic area may be useful for this purpose. Electrocardiography using synthesized right-sided chest leads (Syn-V3R, Syn-V4R, and Syn-V5R) is performed using standard leads without any additional leads. This study evaluated the usefulness of synthesized right-sided chest leads in estimating the origin of ventricular outflow tract arrhythmia. This retrospective study included 63 patients in whom successful ablation of ventricular outflow tract arrhythmia was performed. Numbers of arrhythmias originating from the left ventricle, the septum of the right ventricle, and the free wall of the right ventricle were 11, 40, and 13, respectively. In one patient, two different left ventricular outflow tract origins were found. Electrocardiographic recordings from right-sided chest leads were divided into three types as follows: those in which an R > S concordance, a transitional zone, or an R < S concordance were detected. In all left arrhythmia cases, R > S concordance was observed. A transitional zone was evident in 34 of 40 cases of right ventricular outflow tract arrhythmia originating in the ventricular septum, and an R < S concordance was observed in 6 of the 40 cases. However, an R < S concordance was found in all cases of right ventricular outflow tract arrhythmia originating in the free wall. Synthesized right-sided chest lead electrocardiography may be useful for estimating the origin of ventricular outflow tract arrhythmia.
- Open Access
- 1 January 2013
- Published by The Robotics Society of Japan in Journal of the Robotics Society of Japan
- Vol. 31 (8) , 755-760
Fundamental Study for Assessment for Human Injury by Collision and Fall
- 1 January 2013
- Published by The Robotics Society of Japan in Journal of the Robotics Society of Japan
- Vol. 31 (8) , 755-760
Open AccessFundamental Study for Assessment for Human Injury by Collision and Fall
- Open Access
- 1 January 2011
- Published by Wiley in Journal of Arrhythmia
- Vol. 27 (Supplement) , PJ2_101
Neurally Mediated Syncope in a Patient with Long QT Syndrome
- 1 January 2011
- Published by Wiley in Journal of Arrhythmia
- Vol. 27 (Supplement) , PJ2_101
Open AccessNeurally Mediated Syncope in a Patient with Long QT Syndrome
- Open Access
- 20 November 2007
- Published by Wiley in Journal of Experimental Zoology Part A: Ecological and Integrative Physiology
- Vol. 309A (1) , 17-24
Influence of temperature and darkness on embryonic diapause termination in dormant Artemia cysts that have never been desiccated
Environmental cues for embryonic diapause termination (EDT) were investigated in the laboratory-produced encysted dormant embryos of the brine shrimp, Artemia franciscana. The cysts were spawned and kept throughout in a 2% sea salt solution. They were activated by various temperatures of the temperate zones or by continuous dark condition (DD), resulting in a state of EDT, and were thereafter able to resume their subsequent development and hatch under appropriate conditions. The level of EDT was conveniently assayed by a hatch test observed within 2 days at 28°C under continuous light condition (LL). A cold treatment of the newly spawned dormant cysts, at 4°C under DD for more than 100 days, resulted in more than 95% hatch of the dormant cysts. Similar treatments of the dormant cysts but at room temperature or 28°C led to significantly different results (30–40% hatch). Almost all the residual non-hatched cysts derived from the above could hatch after an additional cold treatment (at 4°C under DD for about 100 days). This might prove to be latent partial bivoltine in Artemia. Meanwhile, a rearing condition (28°C under LL) induced the newly spawned cysts to hatch scatteredly at and after 1 month, resulting in 22% cumulative hatch on the 92nd day after spawning. When the newly spawned dormant cysts were pretreated at 28°C under DD for 5 or 14 days and then reared at 28°C under LL, the cumulative hatch significantly increased (60%). These results are discussed with respect to probable diapause regulator(s) involved in EDT. J. Exp. Zool. 309:17–24, 2008.
- 20 November 2007
- Published by Wiley in Journal of Experimental Zoology Part A: Ecological and Integrative Physiology
- Vol. 309A (1) , 17-24
Open AccessInfluence of temperature and darkness on embryonic diapause termination in dormant Artemia cysts that have never been desiccated
Environmental cues for embryonic diapause termination (EDT) were investigated in the laboratory-produced encysted dormant embryos of the brine shrimp, Artemia franciscana. The cysts were spawned and kept throughout in a 2% sea salt solution. They were activated by various temperatures of the temperate zones or by continuous dark condition (DD), resulting in a state of EDT, and were thereafter able to resume their subsequent development and hatch under appropriate conditions. The level of EDT was conveniently assayed by a hatch test observed within 2 days at 28°C under continuous light condition (LL). A cold treatment of the newly spawned dormant cysts, at 4°C under DD for more than 100 days, resulted in more than 95% hatch of the dormant cysts. Similar treatments of the dormant cysts but at room temperature or 28°C led to significantly different results (30–40% hatch). Almost all the residual non-hatched cysts derived from the above could hatch after an additional cold treatment (at 4°C under DD for about 100 days). This might prove to be latent partial bivoltine in Artemia. Meanwhile, a rearing condition (28°C under LL) induced the newly spawned cysts to hatch scatteredly at and after 1 month, resulting in 22% cumulative hatch on the 92nd day after spawning. When the newly spawned dormant cysts were pretreated at 28°C under DD for 5 or 14 days and then reared at 28°C under LL, the cumulative hatch significantly increased (60%). These results are discussed with respect to probable diapause regulator(s) involved in EDT. J. Exp. Zool. 309:17–24, 2008.