Parallel analysis of finite element model controlled trial and retrospective case control study on percutaneous internal fixation for vertical sacral fractures
Open Access
- 23 July 2013
- journal article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 14 (1) , 217
Abstract
Background: Although percutaneous posterior-ring tension-band metallic plate and percutaneous iliosacral screws are used to fix unstable posterior pelvic ring fractures, the biomechanical stability and compatibility of both internal fixation techniques for the treatment of Denis I, II and III type vertical sacral fractures remain unclear.Methods: Using CT and MR images of the second generation of Chinese Digitized Human “male No. 23”, two groups of finite element models were developed for Denis I, II and III type vertical sacral fractures with ipsilateral superior and inferior pubic ramus fractures treated with either a percutaneous metallic plate or a percutaneous screw. Accordingly, two groups of clinical cases that were fixed using the above-mentioned two internal fixation techniques were retrospectively evaluated to compare postoperative effect and function. Parallel analysis was performed with a finite element model controlled trial and a case control study.Results: The difference of the postoperative Majeed standards and outcome rates between two case groups was no statistically significant (P > 0.05). Accordingly, the high values of the maximum displacements/stresses of the plate-fixation model group approximated those of the screw-fixation model group. However, further simulation of Denis I, II and III type fractures in each group of models found that the biomechanics of the plate-fixation models became increasingly stable and compatible, whereas the biomechanics of the screw-fixation models maintained tiny fluctuations. When treating Denis III fractures, the biomechanical effects of the pelvic ring of the plate-fixation model were better than the screw-fixation model.Conclusions: Percutaneous plate and screw fixations are both appropriate for the treatment of Denis I and II type vertical sacral fractures; whereas percutaneous plate fixation appears be superior to percutaneous screw fixation for Denis III type vertical sacral fracture. Biomechanical evidence of finite element evaluations combined with clinical evidence will contribute to our ability to distinguish between indications that require plate or screw fixation for vertical sacral fractures.Keywords
This publication has 26 references indexed in Scilit:
- Treatment of unstable posterior pelvic ring fracture with percutaneous reconstruction plate and percutaneous sacroiliac screws: a comparative studyJournal of Orthopaedic Science, 2012
- Cartilage thickness in the hip joint measured by MRI and stereology – a methodological studyOsteoarthritis and Cartilage, 2007
- Vertically Unstable Pelvic Fractures Fixed with Percutaneous Iliosacral Screws: Does Posterior Injury Pattern Predict Fixation Failure?Journal of Orthopaedic Trauma, 2003
- Biomechanical Comparison of Posterior Internal Fixation Techniques for Unstable Pelvic FracturesJournal of Orthopaedic Trauma, 1996
- Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic BoneJournal of Biomechanical Engineering, 1995
- Mechanical and textural properties of pelvic trabecular boneJournal of Biomechanics, 1993
- Relation Between Form and Function in the Sacroiliac JointSpine, 1990
- Sacral FracturesClinical Orthopaedics and Related Research, 1988
- Open Reduction and Internal Fixation of Vertical Shear Pelvic Fractures1987
- A measurement of the coefficient of static friction of human long bonesSurface Technology, 1985