ZDZihai Ding

Zihai Ding

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zihai Ding has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Lijun Wu

    Institute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325035 Zhejiang; PR China

    2 shared publications
  • Aimin Wu

    Department of Orthopaedics, Second Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 325000, China

    1 shared publication
  • Chao Chen

    From the *Anatomical Institute of Minimally Invasive Surgery, Southern Medical University, Guangzhou; and †Hand and Foot Surgical Center, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, China

    1 shared publication
  • Dengquan Zheng

    Department of Orthopaedic Surgery, Shucheng People’s Hospitial, Shucheng, Anhui, China

    1 shared publication
  • Dengwei He

    Department of Orthopedics, 5th Affiliated Hospital, Lishui Central Hospital, Wenzhou Medical University, Lishui, 323000, China

    1 shared publication
  • Hongwei Chen

    Cardiac Surgery, Quanzhou First Hospital Affiliated to Fujian Medical University, Quanzhou, 362000 Fujian, China

    1 shared publication

Latest Publications

  • Optimal axis for lumbosacral interbody fusion: Prospective finite element analysis and retrospective 3D‐CT measurement

    by Yang Li, Dengwei He, Nuo Chen, Ting Lv, Aimin Wu, Zhongke Lin, Zihai Ding, Zhengguo Wang, Lijun Wu

    A feasible and optimal axis of biomechanical and anatomic significance in axial lumbosacral interbody fusion (AxiaLIF) was designed. Using the image dataset of an adult volunteer, two groups of finite element (FE) models of the AxiaLIF, lumbosacral anterior column fixation (ACF) models and middle column fixation (MCF) models with different bone graft fusion degrees, were prospectively established, and their biomechanical differences were comparatively predicted. In addition, 3D reconstruction was performed by retrospectively collecting CT data from pelvises in 60 adult cases. Their anatomic parameters relating to two groups of models were digitally measured and statistically compared. Numerical analysis revealed that the load and the maximum stress on the screw as well as the maximum stress difference between the screw and peripheral tissues in the MCF model were reduced compared with the ACF model. These indices of both models all decreased markedly in response to the increase in the disc fusion degree. Statistical analysis revealed that the effective fixed length of the sacrum in the MCF model was increased compared with the ACF model (P < 0.05). The surgical dissection distance of presacral vessels and nerves from the axis to sacrum of the MCF model was reduced compared with the ACF model (P < 0.05). The feasible and optimal axis of biomechanical and anatomic significance of the AxiaLIF is similar to the axis of the MCF model. Disc bone graft fusions plus axial screw fixations of middle column could strengthen the biomechanical stability of the AxiaLIF model. Clin. Anat. 32:337–347, 2019.


  • Full-Length Finger Reconstruction for Proximal Amputation With Expanded Wraparound Great Toe Flap and Vascularized Second Toe Joint

    by Wenhai Sun, Chao Chen, Zengtao Wang, Shenqiang Qiu, Lishan Zhang, Zihai Ding, Shizhen Zhong

    Background Most of the frequently used methods for finger reconstruction have their own limitations. Reconstruction of a full-length finger with normal appearance, in patients with proximal digital amputation, remains a challenge. Methods Between January 2002 and November 2013, a total of 86 fingers (60 patients) with proximal phalanx amputation were surgically repaired. A compound flap comprising an expanded wraparound flap from the great toe and a vascularized proximal interphalangeal (PIP) joint from the second toe was harvested to reconstruct a full-length finger. The flap was used to reconstruct the nail, skin, and the distal phalanx; the PIP joint was used to reconstruct the PIP joint. To attain normal length of the finger and right PIP joint positioning, an iliac bone graft was inserted into the distal-middle or proximal phalanx. Results All reconstructed fingers retained their viability and natural appearance and were of near-normal length with a normal PIP joint positioning; 12.8% (9/86) of the procedures required re-exploration owing to compromised circulation. Secondary procedures were required in 71% (61/86) of the cases. With the exception of 1 case, the donor-site complications were mild; the average range of motion at the other PIP joints was 52 degrees (−15 to −5 degrees of extension, 25–90 degrees of flexion). Approximately 80% of the normal functionality and 93% of the normal appearance with respect to aesthetics were restored. Conclusions The full-length finger reconstruction procedure allows for construction of natural-appearing full-length fingers with normal PIP joint positioning and a near-normal functional recovery for proximal digital amputation. The operation is technically complex and time consuming and demands a skilled operator for successful outcomes.


  • Open Access

    CT and MRI Determination of Intermuscular Space within Lumbar Paraspinal Muscles at Different Intervertebral Disc Levels

    by Xuefei Deng, Youzhi Zhu, Shidong Wang, Yu Zhang, Hui Han, Dengquan Zheng, Zihai Ding, Kelvin K. L. Wong

    Recognition of the intermuscular spaces within lumbar paraspinal muscles is critically important for using the paramedian muscle-splitting approach to the lumbar spine. As such, it is important to determine the intermuscular spaces within the lumbar paraspinal muscles by utilizing modern medical imaging such as computed tomography (CT) and magnetic resonance imaging (MRI). A total of 30 adult cadavers were studied by sectional anatomic dissection, and 60 patients were examined using CT (16 slices, 3-mm thickness, 3-mm intersection gap, n = 30) and MRI (3.0T, T2-WI, 5-mm thickness, 1-mm intersection gap, n = 30). The distances between the midline and the superficial points of the intermuscular spaces at different intervertebral disc levels were measured. Based on study of our cadavers, the mean distances from the midline to the intermuscular space between multifidus and longissimus, from intervertebral disc levels L1–L2 to L5–S1, were 0.9, 1.1, 1.7, 3.0, and 3.5 cm, respectively. Compared with the upper levels (L1–L3), the superficial location at the lower level (L4–S1) is more laterally to the midline (P<0.05). The intermuscular space between sacrospinalis and quadratus lumborum, and that between longissimus and iliocostalis did not exist at L4–S1. The intermuscular spaces in patients also varied at different levels of the lumbar spine showing a low discontinuous density in CT and a high signal in MRI. There were no significant differences between the observations in cadavers and those made using CT and MRI. The intermuscular spaces within the paraspinal muscles vary at different intervertebral disc levels. Preoperative CT and MRI can facilitate selection of the muscle-splitting approach to the lumbar spine. This paper demonstrates the efficacy of medical imaging techniques in surgical planning.


  • Open Access

    Parallel analysis of finite element model controlled trial and retrospective case control study on percutaneous internal fixation for vertical sacral fractures

    by Hongwei Chen, Lijun Wu, Rongmei Zheng, Yan Liu, Yang Li, Zihai Ding

    Background: Although percutaneous posterior-ring tension-band metallic plate and percutaneous iliosacral screws are used to fix unstable posterior pelvic ring fractures, the biomechanical stability and compatibility of both internal fixation techniques for the treatment of Denis I, II and III type vertical sacral fractures remain unclear.Methods: Using CT and MR images of the second generation of Chinese Digitized Human “male No. 23”, two groups of finite element models were developed for Denis I, II and III type vertical sacral fractures with ipsilateral superior and inferior pubic ramus fractures treated with either a percutaneous metallic plate or a percutaneous screw. Accordingly, two groups of clinical cases that were fixed using the above-mentioned two internal fixation techniques were retrospectively evaluated to compare postoperative effect and function. Parallel analysis was performed with a finite element model controlled trial and a case control study.Results: The difference of the postoperative Majeed standards and outcome rates between two case groups was no statistically significant (P > 0.05). Accordingly, the high values of the maximum displacements/stresses of the plate-fixation model group approximated those of the screw-fixation model group. However, further simulation of Denis I, II and III type fractures in each group of models found that the biomechanics of the plate-fixation models became increasingly stable and compatible, whereas the biomechanics of the screw-fixation models maintained tiny fluctuations. When treating Denis III fractures, the biomechanical effects of the pelvic ring of the plate-fixation model were better than the screw-fixation model.Conclusions: Percutaneous plate and screw fixations are both appropriate for the treatment of Denis I and II type vertical sacral fractures; whereas percutaneous plate fixation appears be superior to percutaneous screw fixation for Denis III type vertical sacral fracture. Biomechanical evidence of finite element evaluations combined with clinical evidence will contribute to our ability to distinguish between indications that require plate or screw fixation for vertical sacral fractures.