Purpose. Morbid obesity caries an increased risk of cardiovascular morbidity and might be associated with intraoperative hemodynamic instability. Based on clinical observation, we hypothesized that during laparoscopic surgery, morbidly obese patients behave hemodynamically similar to the nonobese patients and remain hemodynamically stable. Methods. In a prospective trial, thirty nonobese and tthirty morbidly obese (BMI ≥ 35 kg/m2) patients scheduled for elective laparoscopic surgery were assigned to receive standard balanced anesthesia. We aimed at equianesthetic levels by keeping the BIS (bispectral index) value between 40–50 throughout surgery. End-tidal isoflurane was measured every 5 min. Noninvasive hemodynamic measurements included cardiac index (CI), mean arterial pressure (MAP) and heart rate (HR), recorded every 5 min and at specific predetermined times. Systemic vascular resistance (SVR) was calculated. Episodes of MAP ≤ 60 and MAP ≥ 130 mmHg or HR ≤ 50 and HR ≥ 110 bpm occurring throughout surgery and requiring pharmacological intervention were considered main end-points. Additionally, hemodynamic variables were compared at specific time points and overall throughout surgery. Secondary end-points were CI and SVRI. Results. Heart rate was higher in obese patients in head-up position (79 ± 15 mmHg vs. 65 ± 12 mmHg – P=0.011). SVR was higher in the nonobese group with head-up position (1978 ± 665 dynes s cm−5 vs. 1394 ± 496 dynes s cm−5 P=0.01). Mean overall intraoperative MAP, HR, CI and SVR were similar. There were no episodes of MAP ≤ 60 and ≥130 mmHg or HR ≤ 50 and ≥110 bpm in either of the groups. Conclusion. Our study confirmed our hypothesis that for the most periods of laparoscopic surgery, obese patients are hemodynamically as stable as their nonobese counterparts.Keywords
This publication has 16 references indexed in Scilit:
- The effect of obesity on bioimpedance cardiac indexThe American Journal of Surgery, 2005
- The physiologic effect of the pneumoperitoneum on radiofrequency ablationSurgical Endoscopy, 2004
- The Effects of Vasoactive Drugs on Hepatic Blood Flow Changes Induced by CO2 Laparoscopy: An Animal StudyAnesthesia & Analgesia, 2001
- Cardiac function during laparoscopic vs open gastric bypassSurgical Endoscopy, 2001
- The effects of pneumoperitoneum and patient position on hemodynamics during laparoscopic cholecystectomySurgical Endoscopy, 2001
- Hemodynamic Changes During Laparoscopic Gastroplasty in Morbidly Obese PatientsObesity Surgery, 1997
- Continuous intraoperative noninvasive cardiac output monitoring using a new thoracic bioimpedance deviceJournal of Cardiothoracic and Vascular Anesthesia, 1997
- Cardiopulmonary Physiology and Pathophysiology as a Consequence Of Laparoscopic SurgeryChest, 1996
- Hemodynamic changes during laparoscopic cholecystectomy monitored with transesophageal echocardiographySurgical Endoscopy, 1995
- Changes in splanchnic blood flow and cardiovascular effects following peritoneal insufflation of carbon dioxideSurgical Endoscopy, 1993