Nafion Protective Membrane Enables Using Ruthenium Oxide Electrodes for pH Measurement in Milk
Open Access
- 1 October 2021
- journal article
- research article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (10) , 107511
Abstract
The application of conventional glass electrodes for pH measurement in food samples has a serious drawback: glass is fragile and should be handled with care in order to prevent breaking and thus contaminating the food with dangerous shattered fragments. The implementation of all-solid-state sensors allows for pH measurements without this contamination risk but their application in food samples is scarce due to their inability to be used in complex food matrices that contain fats, proteins, yeasts, etc. We can solve this problem by coating solid-state RuO2 electrodes with a semi-permeable protective NafionTM membrane layer. We show that covering screen printed potentiometric RuO2 electrodes with Nafion membrane using a drop-casting technique does not alter the performance of the electrodes in milk samples and provides similar results to the conventional glass electrode. Furthermore, we discovered that thermal treatment of Nafion-layers at 80 °C for 2 h after each layer deposition optimises the performance of the electrodes, makes them usable even in heated aqueous solutions, and increases their lifetime.Keywords
Funding Information
- European Commission (H2020-MSCA-ITN-2018-813680)
- Tallinn University of Technology (development program 2016–2022)
This publication has 54 references indexed in Scilit:
- A Potentiometric Indirect Uric Acid Sensor Based on ZnO Nanoflakes and Immobilized UricaseSensors, 2012
- Development of an Impedimetric Sensor Based on Heteropolyanions with Additional Nafion MembraneSensor Letters, 2011
- Thermally stable improved first-generation glucose biosensors based on Nafion/glucose-oxidase modified heated electrodesElectrochemistry Communications, 2009
- Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and OutlookSensors, 2009
- Morphology of Pt-doped nanofabricated RuO2 sensing electrodes and their properties in water quality monitoring sensorsSensors and Actuators B: Chemical, 2009
- A Review on Correlations between Fish Freshness and pH during Cold StorageAmerican Journal of Biochemistry and Biotechnology, 2008
- Preparation and characteristics of ruthenium dioxide for pH array sensors with real-time measurement systemSensors and Actuators B: Chemical, 2008
- Assessment of shelf-life of maricultured gilthead sea bream (Sparus aurata) stored in iceInternational Journal of Food Science and Technology, 1997
- Novel thick-film pH sensors based on ruthenium dioxide-glass compositesSensors and Actuators B: Chemical, 1995
- Electrochemically-deposited RuO2 films as pH sensorsSensors and Actuators B: Chemical, 1993