Maryna Lazouskaya
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maryna Lazouskaya has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Kiranmai Uppuluri
Łukasiewicz Research Network─Institute of Microelectronics and Photonics (Łukasiewicz─IMiF), Kraków Division, ul. Zabłocie 39, 30-701 Kraków, Poland
4 shared publicationsMartti Tamm
Center of Food and Fermentation Technologies (TFTAK), Mäealuse 2/4, 12618 Tallinn, Estonia
3 shared publications- Ott Scheler
Department of Chemistry and Biotechnology, Tallinn University of Technology, Akadeemia tee 15, 12618 Tallinn, Estonia
3 shared publications Iuliia Vetik
School of Science, Department of Chemistry and Biotechnology, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia
2 shared publications- Kiranmai Uppuluri
Łukasiewicz Research Network—Institute of Microelectronics and Photonics, Kraków Division, ul. Zabłocie 39, 30-701 Kraków, Poland
2 shared publications Krzysztof Zaraska
Ukasiewicz Research NetworkInstitute of Microelectronics and Photonics,Krakow,Poland
2 shared publications
Latest Publications
- Open Access
- 15 September 2023
- Published by Elsevier in Results in Engineering
- Vol. 20, 101425
Monitoring the effect of pH on the growth of pathogenic bacteria using electrical impedance spectroscopy
- 15 September 2023
- Published by Elsevier in Results in Engineering
- Vol. 20, 101425
Open AccessMonitoring the effect of pH on the growth of pathogenic bacteria using electrical impedance spectroscopy
- Open Access
- 30 March 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (14) , 13275-13284
Binary RuO2–CuO Electrodes Outperform RuO2 Electrodes in Measuring the pH in Food Samples
Glass electrodes are the only type of pH-sensitive electrodes currently used in the food industry. While widely used, they have several disadvantages, especially in the areas of brittleness and price. Ruthenium(IV) oxide (RuO2) pH electrodes are a well-known alternative to conventional glass electrodes, providing improved durability and lower price. Nevertheless, partial substitution of RuO2 with cupric oxide (CuO) would further lower the price and reduce the toxicity of the electrode. In this paper, we present the applicability of RuO2-CuO electrodes for pH measurement in food samples. The electrodes were fabricated by screen printing and covered with a protective Nafion membrane. In the experiments with food samples, the RuO2-CuO electrodes outperformed RuO2 electrodes in measuring the pH with an almost twofold higher rate of accurate measurements. The utilization of CuO for the fabrication of pH electrodes allowed the accurate measurement of pH in a larger variety of food samples without compromising the response time.
- 30 March 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (14) , 13275-13284
Open AccessBinary RuO2–CuO Electrodes Outperform RuO2 Electrodes in Measuring the pH in Food Samples
Glass electrodes are the only type of pH-sensitive electrodes currently used in the food industry. While widely used, they have several disadvantages, especially in the areas of brittleness and price. Ruthenium(IV) oxide (RuO2) pH electrodes are a well-known alternative to conventional glass electrodes, providing improved durability and lower price. Nevertheless, partial substitution of RuO2 with cupric oxide (CuO) would further lower the price and reduce the toxicity of the electrode. In this paper, we present the applicability of RuO2-CuO electrodes for pH measurement in food samples. The electrodes were fabricated by screen printing and covered with a protective Nafion membrane. In the experiments with food samples, the RuO2-CuO electrodes outperformed RuO2 electrodes in measuring the pH with an almost twofold higher rate of accurate measurements. The utilization of CuO for the fabrication of pH electrodes allowed the accurate measurement of pH in a larger variety of food samples without compromising the response time.
- 30 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Cleaning Procedure for the Screen-Printed RuO2 pH Electrodes
Screen-printed RuO 2 pH electrodes are suitable for pH determination not only in water samples but also in different food matrixes, e.g., beverages, juices and milk. Nevertheless, the application of the screen-printed RuO 2 electrodes in milk is impossible without covering the electrodes with a protective Nafion membrane that prevents the contamination of the pH-sensitive area of the electrode with sample residues. However, not much attention has been paid to the cleaning procedure of Nafion-covered screen-printed RuO 2 electrodes (RuO 2 -Nf). In this paper, we show that cleaning the electrodes by soaking them in the solution of 5% pepsin in 0.1 M HCI allows restoring the electrode to its initial state for measuring pH in food samples.
- 30 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Cleaning Procedure for the Screen-Printed RuO2 pH Electrodes
Screen-printed RuO 2 pH electrodes are suitable for pH determination not only in water samples but also in different food matrixes, e.g., beverages, juices and milk. Nevertheless, the application of the screen-printed RuO 2 electrodes in milk is impossible without covering the electrodes with a protective Nafion membrane that prevents the contamination of the pH-sensitive area of the electrode with sample residues. However, not much attention has been paid to the cleaning procedure of Nafion-covered screen-printed RuO 2 electrodes (RuO 2 -Nf). In this paper, we show that cleaning the electrodes by soaking them in the solution of 5% pepsin in 0.1 M HCI allows restoring the electrode to its initial state for measuring pH in food samples.
- Open Access
- 1 October 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (10) , 107511
Nafion Protective Membrane Enables Using Ruthenium Oxide Electrodes for pH Measurement in Milk
The application of conventional glass electrodes for pH measurement in food samples has a serious drawback: glass is fragile and should be handled with care in order to prevent breaking and thus contaminating the food with dangerous shattered fragments. The implementation of all-solid-state sensors allows for pH measurements without this contamination risk but their application in food samples is scarce due to their inability to be used in complex food matrices that contain fats, proteins, yeasts, etc. We can solve this problem by coating solid-state RuO2 electrodes with a semi-permeable protective NafionTM membrane layer. We show that covering screen printed potentiometric RuO2 electrodes with Nafion membrane using a drop-casting technique does not alter the performance of the electrodes in milk samples and provides similar results to the conventional glass electrode. Furthermore, we discovered that thermal treatment of Nafion-layers at 80 °C for 2 h after each layer deposition optimises the performance of the electrodes, makes them usable even in heated aqueous solutions, and increases their lifetime.
- 1 October 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (10) , 107511
Open AccessNafion Protective Membrane Enables Using Ruthenium Oxide Electrodes for pH Measurement in Milk
The application of conventional glass electrodes for pH measurement in food samples has a serious drawback: glass is fragile and should be handled with care in order to prevent breaking and thus contaminating the food with dangerous shattered fragments. The implementation of all-solid-state sensors allows for pH measurements without this contamination risk but their application in food samples is scarce due to their inability to be used in complex food matrices that contain fats, proteins, yeasts, etc. We can solve this problem by coating solid-state RuO2 electrodes with a semi-permeable protective NafionTM membrane layer. We show that covering screen printed potentiometric RuO2 electrodes with Nafion membrane using a drop-casting technique does not alter the performance of the electrodes in milk samples and provides similar results to the conventional glass electrode. Furthermore, we discovered that thermal treatment of Nafion-layers at 80 °C for 2 h after each layer deposition optimises the performance of the electrodes, makes them usable even in heated aqueous solutions, and increases their lifetime.
- Open Access
Fabrication, Potentiometric Characterization, and Application of Screen-Printed RuO2 pH Electrodes for Water Quality Testing
Screen-printed sensing electrodes attract much attention for water pollution monitoring due to their small size, physical and chemical durability, and low cost. This paper presents the fabrication and broad potentiometric characterization of RuO2 pH sensing electrodes deposited by screen printing on alumina substrates and sintered in the 800–900 °C temperature range. All the fabricated electrodes showed close to Nernstian sensitivity, good linearity, fast response, small drift, low hysteresis, and low cross-sensitivity toward various interfering cations and anions. Furthermore, decreasing the sintering temperature led to better adhesion of the RuO2 layer and a negligible response to interfering ions. The measurements in real-life samples from different water sources showed that the fabricated electrodes are on par with conventional glass electrodes with a maximum deviation of 0.11 pH units, thus indicating their potential for application in water quality monitoring.
Open AccessFabrication, Potentiometric Characterization, and Application of Screen-Printed RuO2 pH Electrodes for Water Quality Testing
Screen-printed sensing electrodes attract much attention for water pollution monitoring due to their small size, physical and chemical durability, and low cost. This paper presents the fabrication and broad potentiometric characterization of RuO2 pH sensing electrodes deposited by screen printing on alumina substrates and sintered in the 800–900 °C temperature range. All the fabricated electrodes showed close to Nernstian sensitivity, good linearity, fast response, small drift, low hysteresis, and low cross-sensitivity toward various interfering cations and anions. Furthermore, decreasing the sintering temperature led to better adhesion of the RuO2 layer and a negligible response to interfering ions. The measurements in real-life samples from different water sources showed that the fabricated electrodes are on par with conventional glass electrodes with a maximum deviation of 0.11 pH units, thus indicating their potential for application in water quality monitoring.
- 20 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Influence of temperature on the performance of Nafion coated RuO2 based pH electrodes
At present, ruthenium oxide (RuO2) based solid-state electrodes are investigated as an alternative to conventional glass electrode due to their low cost, chemical and physical durability, good sensitivity and fast response. Coverage of the solid-state electrodes with a protective membrane can improve the overall performance of the electrode and allow measurement in complex media, such as blood, food, biologically active environment. One of the well-known protective membranes for electrodes is Nafion. However, little is known about the performance of Nafion-covered electrodes used in heated samples. Here we present the investigation of the behaviour of ruthenium oxide (RuO2) based pH electrodes modified with Nafion protective membrane (RuO2-Nafion) at an elevated temperature of 80°C. RuO2 electrodes were fabricated by screen printing technique. We compare the performance of the RuO2-Nafion electrodes was compared to that of unmodified RuO2 electrodes. Both unmodified RuO2 electrodes and RuO2-Nafion electrodes perform well at room temperature, showing sensitivity close to the theoretical value (58.4 and 62.4 mV/pH respectively), the fast response time (14 and 42 s respectively) and low drift rate (0.5 and 0.4 mV/h respectively). The sensitivity of the Nafion- covered electrodes was found to be higher at elevated temperature as well: 37.2 mV/pH compared to 33.4 mV/pH for unmodified electrodes. Furthermore, RuO2-Nafion electrodes showed a lower drift rate at elevated temperature (9.6 mV/h) compared to that of modified electrodes (34.8 mV/h).
- 20 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Influence of temperature on the performance of Nafion coated RuO2 based pH electrodes
At present, ruthenium oxide (RuO2) based solid-state electrodes are investigated as an alternative to conventional glass electrode due to their low cost, chemical and physical durability, good sensitivity and fast response. Coverage of the solid-state electrodes with a protective membrane can improve the overall performance of the electrode and allow measurement in complex media, such as blood, food, biologically active environment. One of the well-known protective membranes for electrodes is Nafion. However, little is known about the performance of Nafion-covered electrodes used in heated samples. Here we present the investigation of the behaviour of ruthenium oxide (RuO2) based pH electrodes modified with Nafion protective membrane (RuO2-Nafion) at an elevated temperature of 80°C. RuO2 electrodes were fabricated by screen printing technique. We compare the performance of the RuO2-Nafion electrodes was compared to that of unmodified RuO2 electrodes. Both unmodified RuO2 electrodes and RuO2-Nafion electrodes perform well at room temperature, showing sensitivity close to the theoretical value (58.4 and 62.4 mV/pH respectively), the fast response time (14 and 42 s respectively) and low drift rate (0.5 and 0.4 mV/h respectively). The sensitivity of the Nafion- covered electrodes was found to be higher at elevated temperature as well: 37.2 mV/pH compared to 33.4 mV/pH for unmodified electrodes. Furthermore, RuO2-Nafion electrodes showed a lower drift rate at elevated temperature (9.6 mV/h) compared to that of modified electrodes (34.8 mV/h).
- Open Access
Front-Face Fluorimeter for the Determination of Cutting Time of Cheese Curd
The yield of product (cheese) during the cheese-making process depends on the cutting time of the cheese curd. However, the determination of optimal cutting time on an industrial scale is difficult as current standard methods are destructive or analyse only small volumes and not the entire milk to be curdled into cheese. This paper presents a novel front-face fluorimeter (FFF) that is designed to be immersed into a milk batch to enable the determination of the cutting time of cheese curd without the destruction of the sample. The FFF sensor signal corresponds to physical changes in milk during cheese formation and has high predictive power (r > 0.85) and good accuracy (RSE = 30%, considering daily variation between milk samples). The performance of the presented fluorimeter was on par with standard rheological and Berridge methods.
Open AccessFront-Face Fluorimeter for the Determination of Cutting Time of Cheese Curd
The yield of product (cheese) during the cheese-making process depends on the cutting time of the cheese curd. However, the determination of optimal cutting time on an industrial scale is difficult as current standard methods are destructive or analyse only small volumes and not the entire milk to be curdled into cheese. This paper presents a novel front-face fluorimeter (FFF) that is designed to be immersed into a milk batch to enable the determination of the cutting time of cheese curd without the destruction of the sample. The FFF sensor signal corresponds to physical changes in milk during cheese formation and has high predictive power (r > 0.85) and good accuracy (RSE = 30%, considering daily variation between milk samples). The performance of the presented fluorimeter was on par with standard rheological and Berridge methods.
- 6 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Nafion as a protective membrane for screen-printed pH-sensitive ruthenium oxide electrodes
Solid-state electrodes have gained attention in past decades for application in pH sensing as a miniature and mechanically stable alternative to conventional fragile glass electrodes. As a material for solid-state electrodes ruthenium oxide has shown the best characteristics. In this study we investigated the sensitivity and stability of RuO2 screen printed electrodes, produced from the commercially available conductive paste. To enhance the performance, electrodes were coated with Nafion protective layer. Influence of the concentration of Nafion coating solution, drop-casted on the sensitive area of the electrode, was investigated. RuO 2 pH electrodes covered with Nafion layer have shown super- Nernstian response and longer response time, which come into agreement with the result published by other authors previously.
- 6 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Nafion as a protective membrane for screen-printed pH-sensitive ruthenium oxide electrodes
Solid-state electrodes have gained attention in past decades for application in pH sensing as a miniature and mechanically stable alternative to conventional fragile glass electrodes. As a material for solid-state electrodes ruthenium oxide has shown the best characteristics. In this study we investigated the sensitivity and stability of RuO2 screen printed electrodes, produced from the commercially available conductive paste. To enhance the performance, electrodes were coated with Nafion protective layer. Influence of the concentration of Nafion coating solution, drop-casted on the sensitive area of the electrode, was investigated. RuO 2 pH electrodes covered with Nafion layer have shown super- Nernstian response and longer response time, which come into agreement with the result published by other authors previously.
- 1 January 2019
- Published by Springer Nature in Theoretical and Experimental Chemistry
- Vol. 54 (6) , 375-385
Features of the Formation of Interpolyelectrolyte Complexes Based on Chitosan and Pectin
- 1 January 2019
- Published by Springer Nature in Theoretical and Experimental Chemistry
- Vol. 54 (6) , 375-385
Features of the Formation of Interpolyelectrolyte Complexes Based on Chitosan and Pectin
- 1 January 2018
- Published by Pleiades Publishing Ltd in Russian Journal of Physical Chemistry A
- Vol. 92 (1) , 146-152
Formation and Properties of Multilayer Films Based on Polyethyleneimine and Bovine Serum Albumin
(Polyethyleneimine/bovine serum albumin) n ((PEI/BSA) n) multilayer films ( n= 1–10) are produced via the layer-by-later deposition of polyelectrolytes. It is shown that thickness and morphology of...
- 1 January 2018
- Published by Pleiades Publishing Ltd in Russian Journal of Physical Chemistry A
- Vol. 92 (1) , 146-152
Formation and Properties of Multilayer Films Based on Polyethyleneimine and Bovine Serum Albumin
(Polyethyleneimine/bovine serum albumin) n ((PEI/BSA) n) multilayer films ( n= 1–10) are produced via the layer-by-later deposition of polyelectrolytes. It is shown that thickness and morphology of...