Abstract
In LC-filtered permanent magnet synchronous motor (PMSM) drive systems, the voltage waveform at the motor terminals can be reshaped into the sinusoidal profile, thereby enhancing motor longevity. However, the introduction of the LC filter substantially increases model complexity, which necessitates an excessively high-dimensional gain matrix to guarantee observability, thereby posing considerable challenges for observer design. To address this issue, this article proposes an easy-tuning full-order flux observer (ET-FLO) for estimating the state variables and rotor position of the LC-filtered PMSM drives. By analyzing the observer error model in the frequency domain, a single-parameter tuning strategy for pole placement is derived. This strategy greatly simplifies the adjustment of the observer gain matrix, ensuring stable operation across a wide speed range. Furthermore, the adverse effect of speed estimation error on system stability has been fully investigated by constructing an error function, thereby deriving the suitable poles configuration strategy to mitigate system instability. The effectiveness of the proposed strategy has been verified through experimental results on an LC-filtered PMSM drive system.
Funding Information
  • National Natural Science Foundation of China (52421004)

This publication has 32 references indexed in Scilit: