A New Level-Set-Based Protocol for Accurate Bone Segmentation From CT Imaging
Open Access
- 30 September 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 3, 1894-1906
Abstract
A new medical image segmentation pipeline for accurate bone segmentation from computed tomography (CT) imaging is proposed in this paper. It is a two-step methodology, with a pre-segmentation step and a segmentation refinement step, as follows. First, the user performs a rough segmenting of the desired region of interest. Second, a fully automatic refinement step is applied to the pre-segmented data. The automatic segmentation refinement is composed of several sub-steps, namely, image deconvolution, image cropping, and interpolation. The user-defined pre-segmentation is then refined over the deconvolved, cropped, and up-sampled version of the image. The performance of the proposed algorithm is exemplified with the segmentation of CT images of a composite femur bone, reconstructed with different reconstruction protocols. Segmentation outcomes are validated against a gold standard model, obtained using the coordinate measuring machine Nikon Metris LK V20 with a digital line scanner LC60-D and a resolution of $28~\mu \text{m}$ . High sub-pixel accuracy models are obtained for all tested data sets, with a maximum average deviation of 0.178 mm from the gold standard. The algorithm is able to produce high quality segmentation of the composite femur regardless of the surface meshing strategy used.
Keywords
All Related Versions
Funding Information
- Fundação para a Ciência e Tecnologia (FCT), Portugal (UID/EEA/04436/2013)
- FCT for the Ph.D. (SFRH/BDE/51143/2010)
This publication has 48 references indexed in Scilit:
- The Impact of Voxel Size-Based Inaccuracies on the Mechanical Behavior of Thin Bone StructuresAnnals of Biomedical Engineering, 2010
- Effects of CT image segmentation methods on the accuracy of long bone 3D reconstructionsMedical Engineering & Physics, 2010
- High resolution cortical bone thickness measurement from clinical CT dataMedical Image Analysis, 2010
- Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehandInternational Orthopaedics, 2009
- Accuracy analysis of three‐dimensional bone surface models of the forearm constructed from multidetector computed tomography dataThe International Journal of Medical Robotics and Computer Assisted Surgery, 2009
- Evaluation of 4 Multisection CT Systems in Postoperative Imaging of a Cochlear Implant: A Human Cadaver and Phantom StudyAmerican Journal of Neuroradiology, 2008
- Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case studyBMC Musculoskeletal Disorders, 2007
- Contour-based surface reconstruction using MPU implicit modelsGraphical Models, 2007
- A method for measuring the presampled MTF of digital radiographic systems using an edge test deviceMedical Physics, 1998
- Adapting to Unknown Smoothness via Wavelet ShrinkageJournal of the American Statistical Association, 1995