Abstract
We present a small, compact and low-power electronic instrumentation for a point-of-care (PoC) device for the early diagnosis of diabetes mellitus and associated risk factors. The presented system consists of a low-power 4-channel potentiostat, a transducer with 4 separate electrochemical cells featuring different biosensors, and a low-cost printed battery. The system is designed to measure key parameters on diabetes mellitus analysis, such as: glucose, cholesterol and triglycerides. It has been designed as a disposable device using a single blood drop to quantify these parameters, enhancing disposition decision time and improving patient satisfaction when compared with current analytical methodology. The electronic instrumentation has been designed to simultaneously control and read the measurement of the 4 different sensors on the transducer block/chip. In this paper, we present the previous evaluation of the system through different cyclic voltammetry and chronoamperometry analysis compared with a commercial multichannel potentiostat 1030B from CH Instruments. The system presents accurate and reliable performance powered by a printed electrochemical battery.Keywords
This publication has 18 references indexed in Scilit:
- Printed microwells with highly stable thin-film enzyme coatings for point-of-care multiplex bioassay of blood samplesThe Analyst, 2015
- An integrated microfluidic device utilizing dielectrophoresis and multiplex array PCR for point-of-care detection of pathogensLab on a Chip, 2014
- A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function TestingScience Translational Medicine, 2012
- Direct determination of glucose, lactate and triglycerides in blood serum by a tunable quantum cascade laser-based mid-IR sensorApplied Physics B, 2012
- The Accuracy of Point-of-Care Glucose MeasurementsJournal of Diabetes Science and Technology, 2012
- Anemia as a Risk Factor for Cardiovascular Disease and All-Cause Mortality in DiabetesJournal of the American Society of Nephrology, 2005
- Higher prevalence of anemia with diabetes mellitus in moderate kidney insufficiency: The Kidney Early Evaluation ProgramKidney International, 2005
- In-vivo behaviour of hypodermically implanted microfabricated glucose sensorsBiosensors and Bioelectronics, 1991
- Potentially-implantable, amperometric glucose sensors with mediated electron transfer: Improving the operating stabilityBiosensors, 1989
- Clinical Control of Diabetes by the Artificial PancreasDiabetes, 1974