On-board hybrid magnetometer of NASA CHARM-II rocket: principle, design and performances
Open Access
- 6 August 2013
- journal article
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 2 (2) , 137-145
Abstract
We present a hybrid tri-axes magnetometer designed to measure weak magnetic fields in space from DC (direct current) up to a few kHz with a better sensitivity than fluxgate magnetometers at frequencies above a few Hz. This magnetometer combines a wire-wound ferromagnetic ribbon and a classical induction sensor. The nature of the wire-wound ferromagnetic ribbon sensor, giant magneto-impedance or magneto-inductance, is discussed. New configurations of wire-wound ferromagnetic ribbon sensors based on closed magnetic circuits are suggested and the hybrid sensor is described. The electronic conditioning of the wire-wound ribbon makes use of an alternating bias field to cancel the offset and linearize the output. Finally we summarize the main performances of the hybrid magnetometer and we discuss its advantages and drawbacks. A prototype has been built and was part of the scientific payload of the NASA rocket experiment CHARM-II (Correlation of High Frequency and Auroral Roar Measurements) launched in the auroral ionosphere. Unfortunately the launch campaign ended without any noticeable magnetic event and the rocket was eventually launched on 16 February 2010, through a very quiescent arc in the magnetic cusp and no wave activity was detected at frequencies observable by the hybrid magnetometer.Keywords
This publication has 16 references indexed in Scilit:
- Off-diagonal GMI sensor with stress-annealed amorphous ribbonSensors and Actuators A: Physical, 2010
- A Tube-Core Orthogonal Fluxgate Operated in Fundamental ModeIEEE Transactions on Magnetics, 2008
- Finite element method calculations of GMI in thin films and sandwiched structures: Size and edge effectsJournal of Magnetism and Magnetic Materials, 2008
- Induction coil sensors—a reviewMeasurement Science and Technology, 2007
- Advances in fluxgate sensorsSensors and Actuators A: Physical, 2003
- Symmetric response obtained with an orthogonal fluxgate operating in fundamental modeIEEE Transactions on Magnetics, 2002
- Demagnetizing factors for rectangular ferromagnetic prismsJournal of Applied Physics, 1998
- Giant magneto-impedance effect in layered thin filmsIEEE Transactions on Magnetics, 1997
- Magneto-impedance in sandwich film for magnetic sensor headsIEEE Transactions on Magnetics, 1996
- Giant magneto-impedance and magneto-inductive effects in amorphous alloys (invited)Journal of Applied Physics, 1994