CCChristophe Coillot

Christophe Coillot

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christophe Coillot has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Christophe Goze-Bac

    Laboratoire Charles Coulomb (L2C-UMR5221), BioNanoNMRI group, University of Montpellier, Place Eugene Bataillon, 34095 Montpellier, France

    3 shared publications
  • Eric Alibert

    Laboratoire Charles Coulomb (L2C-UMR5221), CNRS, University of Montpellier, Place EugeneBataillon, Montpellier, France

    3 shared publications
  • Eric Nativel

    Institut d'Electronique et des Systèmes (IES-UMR5214), University of Montpellier, Campus Saint-Priest, 34095 Montpellier, France

    2 shared publications
  • Jean-Luc Verdeil

    Centre de Coopération Internationale en Recherche Agronomique pour le Développement (CIRAD), UMR AGAP, Montpellier, France

    2 shared publications
  • Maida Cardoso

    Laboratoire Charles Coulomb (L2C-UMR5221), CNRS, University of Montpellier, Place EugeneBataillon, Montpellier, France

    2 shared publications
  • Maïda Cardoso

    BNIF User facilities, University of Montpellier, CNRS, Montpellier, France

    2 shared publications

Latest Publications

  • Open Access

    Hall effect FEM modeling using FreeFEM++: Illustration on a cross-shaped graphene sensor

    by Vigneswaran Ravi, Sophias Boko, Christophe Coillot, Sébastien Nanot

    The Hall effect, which occurs in metals and semiconductors, is used in numerous applications, particularly in the fabrication of magnetic field sensors. This phenomenon is influenced by the physical properties of the material (electron mobility, doping), the geometry of the device, and the size and position of the metallic contacts. The analytical model has limitations in accurately capturing all these phenomena. Therefore, in this work, we propose a finite element model using FreeFEM++ to accurately model the Hall effect. The validity of this model is assessed by comparing it to analytical ones. The effect of physical defects on the electrical measurements, which cannot be analytically calculated, is explored to illustrate the usefulness of this model under realistic conditions. These simulations can be used both as teaching tools, to illustrate this physical effect and as research tools, as demonstrated in the case of a graphene-based transistor. The reported simulation script is openly shared.

  • Open Access

    Homogenous nuclear magnetic resonance probe using the space harmonics suppression method

    by Pauline de Pellegars, Liu Pan, Rahima Sidi-Boulenouar, Eric Nativel, Michel Zanca, Eric Alibert, Sébastien Rousset, Maida Cardoso, Jean-Luc Verdeil, Nadia Bertin, et al.

    Nuclear magnetic resonance imaging (MRI) has became an unavoidable medical tool in spite of its poor sensitivity. This fact motivates the efforts to enhance the nuclear magnetic resonance (NMR) probe performance. Thus, the nuclear spin excitation and detection, classically performed using radio-frequency coils, are required to be highly sensitive and homogeneous. The space harmonics suppression (SHS) method, already demonstrated to construct coil producing homogenous static magnetic field, is used in this work to design radio-frequency coils. The SHS method is used to determine the distribution of the electrical conductive wires which are organized in a saddle-coil-like configuration. The theoretical study of these SHS coils allows one to expect an enhancement of the signal-to-noise ratio with respect to saddle coil. Coils prototypes were constructed and tested to measure 1H NMR signal at a low magnetic field (8 mT) and perform MRI acquired at a high magnetic field (3 T). The signal-to-noise ratios of these SHS coils are compared to the one of saddle coil and birdcage (in the 3 T case) of the same size under the same pulse sequence conditions demonstrating the performance enhancement allowed by the SHS coils.


  • Multiscale NMR investigations of two anatomically contrasted genotypes of sorghum under watered conditions and during drought stress

    by Rahima Sidi‐Boulenouar, Maïda Cardoso, Christophe Coillot, Sébastien Rousset, Eric Nativel, Alain Charbit, Christelle Baptiste, Eric Alibert, Frédéric Gatineau, Jean‐Luc Verdeil, et al.

    Today, in the presence of global warming, understanding how plants respond to drought stress is essential to meet the challenge of developing new cultivars and new irrigation strategies, consistent with the maintenance of crop productivity. In this context, the study of the relation between plants and water is of central interest for modeling their responses to biotic and abiotic constraints. Paradoxically, there are very few direct and noninvasive methods to quantify and measure the level and the flow of water in plants. The present work aims to develop a noninvasive methodology for living plant based on nuclear magnetic resonance (NMR) at low magnetic field and imaging (MRI) to tackle the issue of water quantity in plants. For this purpose, a portable NMR device measuring the signal level at 8 mT was built. This instrument addresses specific challenges such as miniaturization, accessibility, and overheating in order to maintain the plant intact of time over long period. Time dependence of the water content in sorghum plants is reported under abiotic stress as well as the fraction of transpirable soil water and the photosynthesis activity through the leaves. At high magnetic field (9.4 T), T2 maps were acquired on the same sorghum plants at two time points. The combination of these approaches allows us to identify ecophysiological biomarkers of drought stress. One particular interesting result concerns the spatial distribution of water in two anatomically contrasted sorghum genotypes.


  • Longitudinal Magnetic Resonance Imaging Analysis and Histological Characterization after Spinal Cord Injury in Two Mouse Strains with Different Functional Recovery: Gliosis as a Key Factor

    by Harun Najib Noristani, Guillaume Patrick Saint-Martin, Maïda Cardoso, Rahima Sidiboulenouar, Matthias Catteau, Christophe Coillot, Christophe Goze-Bac, Florence Evelyne Perrin

    Spinal cord injuries (SCI) are disastrous neuropathologies causing permanent disabilities. The availability of different strains of mice is valuable for studying the pathophysiological mechanisms involved in SCI. However, strain differences have a profound effect on spontaneous functional recovery after SCI. CX3CR1 +/eGFP and Aldh1l1-EGFP mice that express green fluorescent protein in microglia/monocytes and astrocytes, respectively, are particularly useful to study glial reactivity. Whereas CX3CR1 +/eGFP mice have C57BL/6 background, Aldh1l1-EGFP are in Swiss Webster background. We first assessed spontaneous functional recovery in CX3CR1 +/eGFP and Aldh1l1-EGFP mice over 6 weeks after lateral spinal cord hemisection. Second, we carried out a longitudinal follow-up of lesion evolution using in vivo T2-weighted magnetic resonance imaging (MRI). Finally, we performed in-depth analysis of the spinal cord tissue using ex vivo T2-weighted MRI as well as detailed histology. We demonstrate that CX3CR1 +/eGFP mice have improved functional recovery and reduced anxiety after SCI compared with Aldh1l1-EGFP mice. We also found a strong correlation between in vivo MRI, ex vivo MRI, and histological analyses of the injured spinal cord in both strain of mice. All three modalities revealed no difference in lesion extension and volume between the two strains of mice. Importantly, histopathological analysis identified decreased gliosis and increased serotonergic axons in CX3CR1 +/eGFP compared with Aldh1l1-EGFP mice following SCI. These results thus suggest that the strain-dependent improved functional recovery after SCI may be linked with reduced gliosis and increased serotonergic innervation.


  • Open Access

    Flip-flop method: A new T1-weighted flow-MRI for plants studies

    by Simon Buy, Simon Le Floch, Ning Tang, Rahima Sidiboulenouar, Michel Zanca, Patrick Canadas, Eric Nativel, Maida Cardoso, Eric Alibert, Guillaume Dupont, et al.

    The climate warming implies an increase of stress of plants (drought and torrential rainfall). The understanding of plant behavior, in this context, takes a major importance and sap flow measurement in plants remains a key issue for plant understanding. Magnetic Resonance Imaging (MRI) which is well known to be a powerful tool to access water quantity can be used to measure moving water. We describe a novel flow-MRI method which takes advantage of inflow slice sensitivity. The method involves the slice selectivity in the context of multi slice spin echo sequence. Two sequences such as a given slice is consecutively inflow and outflow sensitive are performed, offering the possiblility to perform slow flow sensitive imaging in a quite straigthforward way. The method potential is demonstrated by imaging both a slow flow measurement on a test bench (as low as 10 μm.s−1) and the Poiseuille’s profile of xylemian sap flow velocity in the xylematic tissues of a tomato plant stem.


  • Open Access

    On-board hybrid magnetometer of NASA CHARM-II rocket: principle, design and performances

    by C. Coillot, J. Moutoussamy, G. Chanteur, P. Robert, F. Alves

    We present a hybrid tri-axes magnetometer designed to measure weak magnetic fields in space from DC (direct current) up to a few kHz with a better sensitivity than fluxgate magnetometers at frequencies above a few Hz. This magnetometer combines a wire-wound ferromagnetic ribbon and a classical induction sensor. The nature of the wire-wound ferromagnetic ribbon sensor, giant magneto-impedance or magneto-inductance, is discussed. New configurations of wire-wound ferromagnetic ribbon sensors based on closed magnetic circuits are suggested and the hybrid sensor is described. The electronic conditioning of the wire-wound ribbon makes use of an alternating bias field to cancel the offset and linearize the output. Finally we summarize the main performances of the hybrid magnetometer and we discuss its advantages and drawbacks. A prototype has been built and was part of the scientific payload of the NASA rocket experiment CHARM-II (Correlation of High Frequency and Auroral Roar Measurements) launched in the auroral ionosphere. Unfortunately the launch campaign ended without any noticeable magnetic event and the rocket was eventually launched on 16 February 2010, through a very quiescent arc in the magnetic cusp and no wave activity was detected at frequencies observable by the hybrid magnetometer.