Christophe Coillot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christophe Coillot has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Christophe Goze-Bac
Laboratoire Charles Coulomb (L2C-UMR5221), BioNanoNMRI group, University of Montpellier, Place Eugene Bataillon, 34095 Montpellier, France
3 shared publications Eric Alibert
Laboratoire Charles Coulomb (L2C-UMR5221), CNRS, University of Montpellier, Place EugeneBataillon, Montpellier, France
3 shared publicationsEric Nativel
Institut d'Electronique et des Systèmes (IES-UMR5214), University of Montpellier, Campus Saint-Priest, 34095 Montpellier, France
2 shared publicationsJean-Luc Verdeil
Centre de Coopération Internationale en Recherche Agronomique pour le Développement (CIRAD), UMR AGAP, Montpellier, France
2 shared publicationsMaida Cardoso
Laboratoire Charles Coulomb (L2C-UMR5221), CNRS, University of Montpellier, Place EugeneBataillon, Montpellier, France
2 shared publications- Maïda Cardoso
BNIF User facilities, University of Montpellier, CNRS, Montpellier, France
2 shared publications
Latest Publications
- Open Access
- 24 September 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (9) , e0357905
Hall effect FEM modeling using FreeFEM++: Illustration on a cross-shaped graphene sensor
The Hall effect, which occurs in metals and semiconductors, is used in numerous applications, particularly in the fabrication of magnetic field sensors. This phenomenon is influenced by the physical properties of the material (electron mobility, doping), the geometry of the device, and the size and position of the metallic contacts. The analytical model has limitations in accurately capturing all these phenomena. Therefore, in this work, we propose a finite element model using FreeFEM++ to accurately model the Hall effect. The validity of this model is assessed by comparing it to analytical ones. The effect of physical defects on the electrical measurements, which cannot be analytically calculated, is explored to illustrate the usefulness of this model under realistic conditions. These simulations can be used both as teaching tools, to illustrate this physical effect and as research tools, as demonstrated in the case of a graphene-based transistor. The reported simulation script is openly shared.
- 24 September 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (9) , e0357905
Open AccessHall effect FEM modeling using FreeFEM++: Illustration on a cross-shaped graphene sensor
The Hall effect, which occurs in metals and semiconductors, is used in numerous applications, particularly in the fabrication of magnetic field sensors. This phenomenon is influenced by the physical properties of the material (electron mobility, doping), the geometry of the device, and the size and position of the metallic contacts. The analytical model has limitations in accurately capturing all these phenomena. Therefore, in this work, we propose a finite element model using FreeFEM++ to accurately model the Hall effect. The validity of this model is assessed by comparing it to analytical ones. The effect of physical defects on the electrical measurements, which cannot be analytically calculated, is explored to illustrate the usefulness of this model under realistic conditions. These simulations can be used both as teaching tools, to illustrate this physical effect and as research tools, as demonstrated in the case of a graphene-based transistor. The reported simulation script is openly shared.
- Open Access
- 26 March 2020
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 9 (1) , 117-125
Homogenous nuclear magnetic resonance probe using the space harmonics suppression method
Nuclear magnetic resonance imaging (MRI) has became an unavoidable medical tool in spite of its poor sensitivity. This fact motivates the efforts to enhance the nuclear magnetic resonance (NMR) probe performance. Thus, the nuclear spin excitation and detection, classically performed using radio-frequency coils, are required to be highly sensitive and homogeneous. The space harmonics suppression (SHS) method, already demonstrated to construct coil producing homogenous static magnetic field, is used in this work to design radio-frequency coils. The SHS method is used to determine the distribution of the electrical conductive wires which are organized in a saddle-coil-like configuration. The theoretical study of these SHS coils allows one to expect an enhancement of the signal-to-noise ratio with respect to saddle coil. Coils prototypes were constructed and tested to measure 1H NMR signal at a low magnetic field (8 mT) and perform MRI acquired at a high magnetic field (3 T). The signal-to-noise ratios of these SHS coils are compared to the one of saddle coil and birdcage (in the 3 T case) of the same size under the same pulse sequence conditions demonstrating the performance enhancement allowed by the SHS coils.
- 26 March 2020
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 9 (1) , 117-125
Open AccessHomogenous nuclear magnetic resonance probe using the space harmonics suppression method
Nuclear magnetic resonance imaging (MRI) has became an unavoidable medical tool in spite of its poor sensitivity. This fact motivates the efforts to enhance the nuclear magnetic resonance (NMR) probe performance. Thus, the nuclear spin excitation and detection, classically performed using radio-frequency coils, are required to be highly sensitive and homogeneous. The space harmonics suppression (SHS) method, already demonstrated to construct coil producing homogenous static magnetic field, is used in this work to design radio-frequency coils. The SHS method is used to determine the distribution of the electrical conductive wires which are organized in a saddle-coil-like configuration. The theoretical study of these SHS coils allows one to expect an enhancement of the signal-to-noise ratio with respect to saddle coil. Coils prototypes were constructed and tested to measure 1H NMR signal at a low magnetic field (8 mT) and perform MRI acquired at a high magnetic field (3 T). The signal-to-noise ratios of these SHS coils are compared to the one of saddle coil and birdcage (in the 3 T case) of the same size under the same pulse sequence conditions demonstrating the performance enhancement allowed by the SHS coils.
- 25 June 2019
- Published by Wiley in Magnetic Resonance in Chemistry
- Vol. 57 (9) , 749-756
Multiscale NMR investigations of two anatomically contrasted genotypes of sorghum under watered conditions and during drought stress
Today, in the presence of global warming, understanding how plants respond to drought stress is essential to meet the challenge of developing new cultivars and new irrigation strategies, consistent with the maintenance of crop productivity. In this context, the study of the relation between plants and water is of central interest for modeling their responses to biotic and abiotic constraints. Paradoxically, there are very few direct and noninvasive methods to quantify and measure the level and the flow of water in plants. The present work aims to develop a noninvasive methodology for living plant based on nuclear magnetic resonance (NMR) at low magnetic field and imaging (MRI) to tackle the issue of water quantity in plants. For this purpose, a portable NMR device measuring the signal level at 8 mT was built. This instrument addresses specific challenges such as miniaturization, accessibility, and overheating in order to maintain the plant intact of time over long period. Time dependence of the water content in sorghum plants is reported under abiotic stress as well as the fraction of transpirable soil water and the photosynthesis activity through the leaves. At high magnetic field (9.4 T), T2 maps were acquired on the same sorghum plants at two time points. The combination of these approaches allows us to identify ecophysiological biomarkers of drought stress. One particular interesting result concerns the spatial distribution of water in two anatomically contrasted sorghum genotypes.
- 25 June 2019
- Published by Wiley in Magnetic Resonance in Chemistry
- Vol. 57 (9) , 749-756
Multiscale NMR investigations of two anatomically contrasted genotypes of sorghum under watered conditions and during drought stress
Today, in the presence of global warming, understanding how plants respond to drought stress is essential to meet the challenge of developing new cultivars and new irrigation strategies, consistent with the maintenance of crop productivity. In this context, the study of the relation between plants and water is of central interest for modeling their responses to biotic and abiotic constraints. Paradoxically, there are very few direct and noninvasive methods to quantify and measure the level and the flow of water in plants. The present work aims to develop a noninvasive methodology for living plant based on nuclear magnetic resonance (NMR) at low magnetic field and imaging (MRI) to tackle the issue of water quantity in plants. For this purpose, a portable NMR device measuring the signal level at 8 mT was built. This instrument addresses specific challenges such as miniaturization, accessibility, and overheating in order to maintain the plant intact of time over long period. Time dependence of the water content in sorghum plants is reported under abiotic stress as well as the fraction of transpirable soil water and the photosynthesis activity through the leaves. At high magnetic field (9.4 T), T2 maps were acquired on the same sorghum plants at two time points. The combination of these approaches allows us to identify ecophysiological biomarkers of drought stress. One particular interesting result concerns the spatial distribution of water in two anatomically contrasted sorghum genotypes.
- 13 December 2018
- Published by SAGE Publications in Journal of Neurotrauma
- Vol. 35 (24) , 2924-2940
Longitudinal Magnetic Resonance Imaging Analysis and Histological Characterization after Spinal Cord Injury in Two Mouse Strains with Different Functional Recovery: Gliosis as a Key Factor
Spinal cord injuries (SCI) are disastrous neuropathologies causing permanent disabilities. The availability of different strains of mice is valuable for studying the pathophysiological mechanisms involved in SCI. However, strain differences have a profound effect on spontaneous functional recovery after SCI. CX3CR1 +/eGFP and Aldh1l1-EGFP mice that express green fluorescent protein in microglia/monocytes and astrocytes, respectively, are particularly useful to study glial reactivity. Whereas CX3CR1 +/eGFP mice have C57BL/6 background, Aldh1l1-EGFP are in Swiss Webster background. We first assessed spontaneous functional recovery in CX3CR1 +/eGFP and Aldh1l1-EGFP mice over 6 weeks after lateral spinal cord hemisection. Second, we carried out a longitudinal follow-up of lesion evolution using in vivo T2-weighted magnetic resonance imaging (MRI). Finally, we performed in-depth analysis of the spinal cord tissue using ex vivo T2-weighted MRI as well as detailed histology. We demonstrate that CX3CR1 +/eGFP mice have improved functional recovery and reduced anxiety after SCI compared with Aldh1l1-EGFP mice. We also found a strong correlation between in vivo MRI, ex vivo MRI, and histological analyses of the injured spinal cord in both strain of mice. All three modalities revealed no difference in lesion extension and volume between the two strains of mice. Importantly, histopathological analysis identified decreased gliosis and increased serotonergic axons in CX3CR1 +/eGFP compared with Aldh1l1-EGFP mice following SCI. These results thus suggest that the strain-dependent improved functional recovery after SCI may be linked with reduced gliosis and increased serotonergic innervation.
- 13 December 2018
- Published by SAGE Publications in Journal of Neurotrauma
- Vol. 35 (24) , 2924-2940
Longitudinal Magnetic Resonance Imaging Analysis and Histological Characterization after Spinal Cord Injury in Two Mouse Strains with Different Functional Recovery: Gliosis as a Key Factor
Spinal cord injuries (SCI) are disastrous neuropathologies causing permanent disabilities. The availability of different strains of mice is valuable for studying the pathophysiological mechanisms involved in SCI. However, strain differences have a profound effect on spontaneous functional recovery after SCI. CX3CR1 +/eGFP and Aldh1l1-EGFP mice that express green fluorescent protein in microglia/monocytes and astrocytes, respectively, are particularly useful to study glial reactivity. Whereas CX3CR1 +/eGFP mice have C57BL/6 background, Aldh1l1-EGFP are in Swiss Webster background. We first assessed spontaneous functional recovery in CX3CR1 +/eGFP and Aldh1l1-EGFP mice over 6 weeks after lateral spinal cord hemisection. Second, we carried out a longitudinal follow-up of lesion evolution using in vivo T2-weighted magnetic resonance imaging (MRI). Finally, we performed in-depth analysis of the spinal cord tissue using ex vivo T2-weighted MRI as well as detailed histology. We demonstrate that CX3CR1 +/eGFP mice have improved functional recovery and reduced anxiety after SCI compared with Aldh1l1-EGFP mice. We also found a strong correlation between in vivo MRI, ex vivo MRI, and histological analyses of the injured spinal cord in both strain of mice. All three modalities revealed no difference in lesion extension and volume between the two strains of mice. Importantly, histopathological analysis identified decreased gliosis and increased serotonergic axons in CX3CR1 +/eGFP compared with Aldh1l1-EGFP mice following SCI. These results thus suggest that the strain-dependent improved functional recovery after SCI may be linked with reduced gliosis and increased serotonergic innervation.
- Open Access
- 29 March 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (3) , e0194845
Flip-flop method: A new T1-weighted flow-MRI for plants studies
The climate warming implies an increase of stress of plants (drought and torrential rainfall). The understanding of plant behavior, in this context, takes a major importance and sap flow measurement in plants remains a key issue for plant understanding. Magnetic Resonance Imaging (MRI) which is well known to be a powerful tool to access water quantity can be used to measure moving water. We describe a novel flow-MRI method which takes advantage of inflow slice sensitivity. The method involves the slice selectivity in the context of multi slice spin echo sequence. Two sequences such as a given slice is consecutively inflow and outflow sensitive are performed, offering the possiblility to perform slow flow sensitive imaging in a quite straigthforward way. The method potential is demonstrated by imaging both a slow flow measurement on a test bench (as low as 10 μm.s−1) and the Poiseuille’s profile of xylemian sap flow velocity in the xylematic tissues of a tomato plant stem.
- 29 March 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (3) , e0194845
Open AccessFlip-flop method: A new T1-weighted flow-MRI for plants studies
The climate warming implies an increase of stress of plants (drought and torrential rainfall). The understanding of plant behavior, in this context, takes a major importance and sap flow measurement in plants remains a key issue for plant understanding. Magnetic Resonance Imaging (MRI) which is well known to be a powerful tool to access water quantity can be used to measure moving water. We describe a novel flow-MRI method which takes advantage of inflow slice sensitivity. The method involves the slice selectivity in the context of multi slice spin echo sequence. Two sequences such as a given slice is consecutively inflow and outflow sensitive are performed, offering the possiblility to perform slow flow sensitive imaging in a quite straigthforward way. The method potential is demonstrated by imaging both a slow flow measurement on a test bench (as low as 10 μm.s−1) and the Poiseuille’s profile of xylemian sap flow velocity in the xylematic tissues of a tomato plant stem.
- Open Access
- 6 August 2013
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 2 (2) , 137-145
On-board hybrid magnetometer of NASA CHARM-II rocket: principle, design and performances
We present a hybrid tri-axes magnetometer designed to measure weak magnetic fields in space from DC (direct current) up to a few kHz with a better sensitivity than fluxgate magnetometers at frequencies above a few Hz. This magnetometer combines a wire-wound ferromagnetic ribbon and a classical induction sensor. The nature of the wire-wound ferromagnetic ribbon sensor, giant magneto-impedance or magneto-inductance, is discussed. New configurations of wire-wound ferromagnetic ribbon sensors based on closed magnetic circuits are suggested and the hybrid sensor is described. The electronic conditioning of the wire-wound ribbon makes use of an alternating bias field to cancel the offset and linearize the output. Finally we summarize the main performances of the hybrid magnetometer and we discuss its advantages and drawbacks. A prototype has been built and was part of the scientific payload of the NASA rocket experiment CHARM-II (Correlation of High Frequency and Auroral Roar Measurements) launched in the auroral ionosphere. Unfortunately the launch campaign ended without any noticeable magnetic event and the rocket was eventually launched on 16 February 2010, through a very quiescent arc in the magnetic cusp and no wave activity was detected at frequencies observable by the hybrid magnetometer.
- 6 August 2013
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 2 (2) , 137-145
Open AccessOn-board hybrid magnetometer of NASA CHARM-II rocket: principle, design and performances
We present a hybrid tri-axes magnetometer designed to measure weak magnetic fields in space from DC (direct current) up to a few kHz with a better sensitivity than fluxgate magnetometers at frequencies above a few Hz. This magnetometer combines a wire-wound ferromagnetic ribbon and a classical induction sensor. The nature of the wire-wound ferromagnetic ribbon sensor, giant magneto-impedance or magneto-inductance, is discussed. New configurations of wire-wound ferromagnetic ribbon sensors based on closed magnetic circuits are suggested and the hybrid sensor is described. The electronic conditioning of the wire-wound ribbon makes use of an alternating bias field to cancel the offset and linearize the output. Finally we summarize the main performances of the hybrid magnetometer and we discuss its advantages and drawbacks. A prototype has been built and was part of the scientific payload of the NASA rocket experiment CHARM-II (Correlation of High Frequency and Auroral Roar Measurements) launched in the auroral ionosphere. Unfortunately the launch campaign ended without any noticeable magnetic event and the rocket was eventually launched on 16 February 2010, through a very quiescent arc in the magnetic cusp and no wave activity was detected at frequencies observable by the hybrid magnetometer.