Real‐world experience with leadless cardiac pacing
- 11 January 2019
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 42 (3) , 366-373
Abstract
Background: Leadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers.Methods: Patients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age‐ and sex‐matched controls receiving single‐chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA).Results: Ninety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow‐up duration of 62 (interquartile range 28‐169) days. Both groups had 100% successful device implant rates. There were no differences in procedure‐related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device‐related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017).Conclusion: There are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device‐related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.Keywords
This publication has 16 references indexed in Scilit:
- Progressive right ventricular enlargement due to pulmonary regurgitation: Clinical characteristics of a “low-risk” groupAmerican Heart Journal, 2018
- A leadless pacemaker in the real-world setting: The Micra Transcatheter Pacing System Post-Approval RegistryHeart Rhythm, 2017
- Leadless pacing meets the real world: The maturation of clinical evidence behind a miniaturized pacemakerHeart Rhythm, 2017
- Right ventricular and tricuspid valve function in patients chronically implanted with leadless pacemakersEP Europace, 2017
- Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing StudyHeart Rhythm, 2017
- Cardiac Pacemakers: Function, Troubleshooting, and ManagementJACC, 2017
- A Leadless Intracardiac Transcatheter Pacing SystemNew England Journal of Medicine, 2016
- Percutaneous Implantation of an Entirely Intracardiac Leadless PacemakerThe New England journal of medicine, 2015
- Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing StudyEuropean Heart Journal, 2015
- Severe Symptomatic Tricuspid Valve Regurgitation Due to Permanent Pacemaker or Implantable Cardioverter-Defibrillator LeadsJACC, 2005