James D. Ryan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
James D. Ryan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Samuel J. Asirvatham
Department of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
3 shared publications- Yong-Mei Cha
Department of Cardiovascular Medicine Mayo Clinic Rochester Minnesota USA
3 shared publications David L. Hayes
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
2 shared publicationsDean D. Engle
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
2 shared publicationsNathan D. Tempel
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
2 shared publicationsFred Kusumoto
Department of Cardiovascular Diseases, Mayo Clinic, Jacksonville, Florida
1 shared publication
Latest Publications
- 11 January 2019
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 42 (3) , 366-373
Real‐world experience with leadless cardiac pacing
Background: Leadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers.Methods: Patients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age‐ and sex‐matched controls receiving single‐chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA).Results: Ninety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow‐up duration of 62 (interquartile range 28‐169) days. Both groups had 100% successful device implant rates. There were no differences in procedure‐related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device‐related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017).Conclusion: There are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device‐related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.
- 11 January 2019
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 42 (3) , 366-373
Real‐world experience with leadless cardiac pacing
Background: Leadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers.Methods: Patients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age‐ and sex‐matched controls receiving single‐chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA).Results: Ninety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow‐up duration of 62 (interquartile range 28‐169) days. Both groups had 100% successful device implant rates. There were no differences in procedure‐related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device‐related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017).Conclusion: There are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device‐related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.
- 1 February 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (3) , 340
Oversensing of transthoracic excitation stimuli in contemporary pacemakers
- 1 February 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (3) , 340
Oversensing of transthoracic excitation stimuli in contemporary pacemakers
- 5 January 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (2) , 161-166
Oversensing of transthoracic excitation stimuli in contemporary pacemakers
Background: Transthoracic impedance measurements (TIM) is primarily used for minute ventilation rate adaptive sensors in pacemakers. With elevated impedance, the TIM electrical signal itself is oversensed, causing device malfunction.Objective: We report an increased incidence of TIM oversensing.Method: Retrospective chart review. We review existing records of 18 patients who have demonstrated device malfunction with TIM oversensing.Results: We have found a 1.8% incidence of TIM‐related oversensing in our patient population of 959 patients with contemporary Boston Scientific (Marlborough, MA, USA) pacemakers and cardiac resynchronization therapy pacemakers. One patient experienced a syncopal episode.Conclusion: Oversensing with pacing inhibition is apparent with the potential of adverse effects to patients.
- 5 January 2018
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (2) , 161-166
Oversensing of transthoracic excitation stimuli in contemporary pacemakers
Background: Transthoracic impedance measurements (TIM) is primarily used for minute ventilation rate adaptive sensors in pacemakers. With elevated impedance, the TIM electrical signal itself is oversensed, causing device malfunction.Objective: We report an increased incidence of TIM oversensing.Method: Retrospective chart review. We review existing records of 18 patients who have demonstrated device malfunction with TIM oversensing.Results: We have found a 1.8% incidence of TIM‐related oversensing in our patient population of 959 patients with contemporary Boston Scientific (Marlborough, MA, USA) pacemakers and cardiac resynchronization therapy pacemakers. One patient experienced a syncopal episode.Conclusion: Oversensing with pacing inhibition is apparent with the potential of adverse effects to patients.