  • Real‐world experience with leadless cardiac pacing

    by Vaibhav R. Vaidya, Mingyan Dai, Samuel J. Asirvatham, Robert F. Rea, Trena M. Thome, Komandoor Srivathsan, Siva K. Mulpuru, Fred Kusumoto, Kalpathi L. Venkatachalam, James D. Ryan, et al.

    Background: Leadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers.Methods: Patients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age‐ and sex‐matched controls receiving single‐chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA).Results: Ninety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow‐up duration of 62 (interquartile range 28‐169) days. Both groups had 100% successful device implant rates. There were no differences in procedure‐related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device‐related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017).Conclusion: There are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device‐related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.


  • Oversensing of transthoracic excitation stimuli in contemporary pacemakers

    by James D. Ryan, Nathan D. Tempel, Dean D. Engle, David L. Hayes, Yong‐Mei Cha, Samuel J. Asirvatham


  • Oversensing of transthoracic excitation stimuli in contemporary pacemakers

    by James D. Ryan, Nathan D. Tempel, Dean D. Engle, David L. Hayes, Yong‐Mei Cha, Samuel J. Asirvatham

    Background: Transthoracic impedance measurements (TIM) is primarily used for minute ventilation rate adaptive sensors in pacemakers. With elevated impedance, the TIM electrical signal itself is oversensed, causing device malfunction.Objective: We report an increased incidence of TIM oversensing.Method: Retrospective chart review. We review existing records of 18 patients who have demonstrated device malfunction with TIM oversensing.Results: We have found a 1.8% incidence of TIM‐related oversensing in our patient population of 959 patients with contemporary Boston Scientific (Marlborough, MA, USA) pacemakers and cardiac resynchronization therapy pacemakers. One patient experienced a syncopal episode.Conclusion: Oversensing with pacing inhibition is apparent with the potential of adverse effects to patients.