Performance characteristics of finger-stick dried blood spots (DBS) on the determination of human immunodeficiency virus (HIV) treatment failure in a pediatric population in Mozambique
Authors:
Open Access
- 13 July 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (7) , e0181054
Abstract
Quantitative plasma viral load (VL) at 1000 copies /mL was recommended as the threshold to confirm antiretroviral therapy (ART) failure by the World Health Organization (WHO). Because of ongoing challenges of using plasma for VL testing in resource-limited settings (RLS), especially for children, this study collected 717 DBS and paired plasma samples from children receiving ART ≥1 year in Mozambique and compared the performance of DBS using Abbott’s VL test with a paired plasma sample using Roche’s VL test. At a cut-off of 1000 copies/mL, sensitivity of DBS using Abbott DBS VL test was 79.9%, better than 71.0% and 63.9% at 3000 and 5000 copies/mL, respectively. Specificities were 97.6%, 98.8%, 99.3% at 1000, 3000, and 5000 copies/mL, respectively. The Kappa value at 1000 copies/mL, 0.80 (95% CI: 0.73, 0.87), was higher than 0.73 (95% CI: 0.66, 0.80) and 0.66 (95% CI: 0.59, 0.73) at 3000, 5000 copies/mL, respectively, also indicating better agreement. The mean difference between the DBS and plasma VL tests with 95% limits of agreement by Bland-Altman was 0.311 (-0.908, 1.530). Among 73 children with plasma VL between 1000 to 5000 copies/mL, the DBS results were undetectable in 53 at the 1000 copies/mL threshold. While one DBS sample in the Abbott DBS VL test may be an alternative method to confirm ART failure at 1000 copies/mL threshold when a plasma sample is not an option for treatment monitoring, because of sensitivity concerns between 1,000 and 5,000 copies/ml, two DBS samples may be preferred accompanied by careful patient monitoring and repeat testing.Keywords
This publication has 26 references indexed in Scilit:
- Birth Diagnosis of HIV Infection in Infants to Reduce Infant Mortality and Monitor for Elimination of Mother-to-child TransmissionThe Pediatric Infectious Disease Journal, 2013
- Early Diagnosis of In Utero and Intrapartum HIV Infection in Infants Prior to 6 Weeks of AgeJournal of Clinical Microbiology, 2012
- Quantification of HIV-RNA from dried blood spots using the Siemens VERSANT(R) HIV-1 RNA (kPCR) assayJournal of Antimicrobial Chemotherapy, 2011
- A Randomized Controlled Trial Comparing the Effects of Counseling and Alarm Device on HAART Adherence and Virologic OutcomesPLOS Medicine, 2011
- Evaluation of a single round polymerase chain reaction assay using dried blood spots for diagnosis of HIV-1 infection in infants in an African settingBMC Pediatrics, 2011
- Comparative Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Version 2 Test Using the TaqMan 48 Analyzer and the Abbott RealTi m e HIV-1 AssayJournal of Clinical Microbiology, 2011
- Evaluation of a dried blood spot HIV-1 RNA program for early infant diagnosis and viral load monitoring at rural and remote healthcare facilitiesAIDS, 2009
- Low-Cost HIV-1 Diagnosis and Quantification in Dried Blood Spots by Real Time PCRPLOS ONE, 2009
- Correlation between Human Immunodeficiency Virus Type 1 (HIV-1) RNA Measurements Obtained with Dried Blood Spots and Those Obtained with Plasma by Use of Nuclisens EasyQ HIV-1 and Abbott RealTime HIV Load TestsJournal of Clinical Microbiology, 2009
- Multicenter Evaluation of Use of Dried Blood and Plasma Spot Specimens in Quantitative Assays for Human Immunodeficiency Virus RNA: Measurement, Precision, and RNA StabilityJournal of Clinical Microbiology, 2003