Evaluation of Measurement Errors in Rotational Stitching, One-Shot, and Slot-Scanning Full-Length Radiography
Open Access
- 19 September 2025
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 999
Abstract
Full-length radiography is essential for evaluating spinal deformities, limb length discrepancies, and preoperative planning in orthopedics, yet the measurement accuracy of different radiographic methods remains unclear. This phantom study compared the accuracy of rotational stitching, one-shot and slot-scanning full-length radiography across six radiographic systems in quantifying distances between anatomical landmarks. Measurement errors were statistically analyzed using appropriate nonparametric tests. The results demonstrated significant differences in measurement accuracy among the three methods (H (2) = 15.86, p < 0.001). Slot-scanning exhibited the highest accuracy, with a mean error of −1.19 ± 10.13 mm, while both rotational stitching and one-shot imaging showed greater systematic underestimation, with mean errors of −18.95 ± 13.77 mm and −15.32 ± 12.38 mm, respectively. These negative biases (approximately 1.9 cm and 1.5 cm) are clinically meaningful because, if unrecognized, they can alter mechanical axis estimation and alignment planning in procedures such as high tibial osteotomy (HTO). Post hoc analysis confirmed the superior accuracy of slot-scanning compared to the other two methods, while no significant difference was found between rotational stitching and one-shot imaging. These findings indicate that system choice substantially impacts measurement accuracy, supporting preferential use of slot-scanning when precise quantitative assessment is required.Keywords
Funding Information
- National Natural Science Foundation of China (32371367, 210H1147900, 23SHS02800-06, 23S31901000)
- Pudong New Area Science & Technology and Development Fund (32371367, 210H1147900, 23SHS02800-06, 23S31901000)
- Shanghai Innovation Medical Device Application Demonstration Project (32371367, 210H1147900, 23SHS02800-06, 23S31901000)
- “Science and Technology Innovation Action Plan” of Science and Technology Commission of Shanghai Municipality (32371367, 210H1147900, 23SHS02800-06, 23S31901000)
This publication has 32 references indexed in Scilit:
- Low-dose lung CT: Optimizing diagnostic radiation dose – A phantom studyEuropean Journal of Radiology Open, 2024
- Distances and angles in standing long-leg radiographs: comparing conventional radiography, digital radiography, and EOSSkeletal Radiology, 2024
- Angular accuracy of plain radiographic measurements in leg alignment: Teleoroentgenogram versus orthoroentgenogramJournal of Orthopaedic Science, 2022
- Heterogeneous Stitching of X-ray Images According to Homographic EvaluationJournal of Digital Imaging, 2021
- Distance from the magnification device contributes to differences in lower leg length measured in patients with TSF correctionArchives of orthopaedic and trauma surgery, 2021
- Leg length and offset differences above 5 mm after total hip arthroplasty are associated with altered gait kinematicsGait & Posture, 2016
- Improvement of automated image stitching system for DR X-ray imagesComputers in Biology and Medicine, 2016
- First test on three stitching methods with digital detectors used in radiographyRadiological Physics and Technology, 2012
- Development of Automated Image Stitching System for Radiographic ImagesJournal of Digital Imaging, 2012
- The EOS™ imaging system and its uses in daily orthopaedic practiceInternational Orthopaedics, 2012