Jie Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Xia has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Kai Yang
Department of Radiology, Shanghai Sixth People’s Hospital, Shanghai, China
2 shared publications - Cong Wang
School of Biomedical Engineering & Med‐X Research Institute Shanghai Jiao Tong University Shanghai China
1 shared publication - Fan Xiao
Institute of Diagnostic and Interventional Radiology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication - Fan Zhang
TAOiMAGE Medical Technologies Corporation, Shanghai 200120, China
1 shared publication - Guang Tan1 shared publication
- Haojie Shan
Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
1 shared publication
Latest Publications
- Open Access
- 9 December 2025
- Published by Elsevier in Journal of Bone Oncology
- Vol. 56, 100733
Mri-based habitat and peritumoral radiomics for predicting the proliferative activity of stromal cells in giant cell tumor of bone
- 9 December 2025
- Published by Elsevier in Journal of Bone Oncology
- Vol. 56, 100733
Open AccessMri-based habitat and peritumoral radiomics for predicting the proliferative activity of stromal cells in giant cell tumor of bone
- Open Access
- 1 December 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (12) , 12655-12668
The correlation between femoral trochlear dysplasia and meniscal tear in young individuals: a finite element analysis based on MRI
Background: Femoral trochlear dysplasia (FTD) and meniscal tear are common knee disorders, yet there is lack of research investigating the correlation between them. We aimed to investigate the prevalence of FTD in young meniscal tear patients, and observe the main tear locations. Meanwhile, we explored the force distribution on meniscus by finite element analysis (FEA). Methods: The magnetic resonance (MR) images of 422 young patients with meniscal tears confirmed by the arthroscopy (the meniscal tears group) and 412 young patients with a history of knee joint pain but without evidence of meniscal tears (the comparison group) were reviewed. The meniscal tears group underwent MR scans before the arthroscopy. FTD was diagnosed according to the Dejour classification. The prevalence of FTD in both groups and the main locations of meniscal tears were observed. The objective radiological parameters were measured in two groups. Multicollinearity testing was carried out, and variables with a variance inflation factor (VIF) value less than 10 were retained in the logistic regression analysis, and statistical difference defined as PResults: The incidence of FTD was higher in the meniscal tears group than the comparison group (36.02% vs. 19.17%, PConclusions: The high-grade FTD was the independent predictor of meniscal tear. The posterior horn of medial meniscus was the most susceptible and this might be related to the increased stress on it confirmed by FEA.
- 1 December 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (12) , 12655-12668
Open AccessThe correlation between femoral trochlear dysplasia and meniscal tear in young individuals: a finite element analysis based on MRI
Background: Femoral trochlear dysplasia (FTD) and meniscal tear are common knee disorders, yet there is lack of research investigating the correlation between them. We aimed to investigate the prevalence of FTD in young meniscal tear patients, and observe the main tear locations. Meanwhile, we explored the force distribution on meniscus by finite element analysis (FEA). Methods: The magnetic resonance (MR) images of 422 young patients with meniscal tears confirmed by the arthroscopy (the meniscal tears group) and 412 young patients with a history of knee joint pain but without evidence of meniscal tears (the comparison group) were reviewed. The meniscal tears group underwent MR scans before the arthroscopy. FTD was diagnosed according to the Dejour classification. The prevalence of FTD in both groups and the main locations of meniscal tears were observed. The objective radiological parameters were measured in two groups. Multicollinearity testing was carried out, and variables with a variance inflation factor (VIF) value less than 10 were retained in the logistic regression analysis, and statistical difference defined as PResults: The incidence of FTD was higher in the meniscal tears group than the comparison group (36.02% vs. 19.17%, PConclusions: The high-grade FTD was the independent predictor of meniscal tear. The posterior horn of medial meniscus was the most susceptible and this might be related to the increased stress on it confirmed by FEA.
- Open Access
- 19 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 999
Evaluation of Measurement Errors in Rotational Stitching, One-Shot, and Slot-Scanning Full-Length Radiography
Full-length radiography is essential for evaluating spinal deformities, limb length discrepancies, and preoperative planning in orthopedics, yet the measurement accuracy of different radiographic methods remains unclear. This phantom study compared the accuracy of rotational stitching, one-shot and slot-scanning full-length radiography across six radiographic systems in quantifying distances between anatomical landmarks. Measurement errors were statistically analyzed using appropriate nonparametric tests. The results demonstrated significant differences in measurement accuracy among the three methods (H (2) = 15.86, p < 0.001). Slot-scanning exhibited the highest accuracy, with a mean error of −1.19 ± 10.13 mm, while both rotational stitching and one-shot imaging showed greater systematic underestimation, with mean errors of −18.95 ± 13.77 mm and −15.32 ± 12.38 mm, respectively. These negative biases (approximately 1.9 cm and 1.5 cm) are clinically meaningful because, if unrecognized, they can alter mechanical axis estimation and alignment planning in procedures such as high tibial osteotomy (HTO). Post hoc analysis confirmed the superior accuracy of slot-scanning compared to the other two methods, while no significant difference was found between rotational stitching and one-shot imaging. These findings indicate that system choice substantially impacts measurement accuracy, supporting preferential use of slot-scanning when precise quantitative assessment is required.
- 19 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 999
Open AccessEvaluation of Measurement Errors in Rotational Stitching, One-Shot, and Slot-Scanning Full-Length Radiography
Full-length radiography is essential for evaluating spinal deformities, limb length discrepancies, and preoperative planning in orthopedics, yet the measurement accuracy of different radiographic methods remains unclear. This phantom study compared the accuracy of rotational stitching, one-shot and slot-scanning full-length radiography across six radiographic systems in quantifying distances between anatomical landmarks. Measurement errors were statistically analyzed using appropriate nonparametric tests. The results demonstrated significant differences in measurement accuracy among the three methods (H (2) = 15.86, p < 0.001). Slot-scanning exhibited the highest accuracy, with a mean error of −1.19 ± 10.13 mm, while both rotational stitching and one-shot imaging showed greater systematic underestimation, with mean errors of −18.95 ± 13.77 mm and −15.32 ± 12.38 mm, respectively. These negative biases (approximately 1.9 cm and 1.5 cm) are clinically meaningful because, if unrecognized, they can alter mechanical axis estimation and alignment planning in procedures such as high tibial osteotomy (HTO). Post hoc analysis confirmed the superior accuracy of slot-scanning compared to the other two methods, while no significant difference was found between rotational stitching and one-shot imaging. These findings indicate that system choice substantially impacts measurement accuracy, supporting preferential use of slot-scanning when precise quantitative assessment is required.